Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
Fire-Lite Alarms ACC-25/50ZS
Honeywell Fire-Lite Alarms ACC-25/50ZS Manuals
Manuals and User Guides for Honeywell Fire-Lite Alarms ACC-25/50ZS. We have
1
Honeywell Fire-Lite Alarms ACC-25/50ZS manual available for free PDF download: Instruction Manual
Honeywell Fire-Lite Alarms ACC-25/50ZS Instruction Manual (144 pages)
Voice Evacuation Control Panels
Brand:
Honeywell
| Category:
Control Panel
| Size: 4.26 MB
Table of Contents
Table of Contents
5
Section 1: Product Description
13
Product Features
14
Specifications
19
Controls and Indicators
23
1: Single Zone Operation (ACC-25/50, ACC-25/50ZS, ACC-25/50ZST)
23
2: Dual Zone Operation (ACC-25/50 Only)
23
3: Record/Playback
24
4: Trouble Silence
24
5: Leds (Visible with Panel Door Closed)
24
6: ACC-ZPMK Zone Page Module (ACC-25/50ZS and ACC-25/50ZST Panels Only)
24
7: ACC-FFT Fire Fighter Telephone Module (ACC-25/50ZST Only)
25
8: ACC-EPM External
25
9: Other System Leds (Located on Main Circuit Board and Modules)
25
Circuits
26
Components
27
Optional Modules
29
Getting Started
30
1: ACC-25/50, Requiring up to 50 Watts of Audio Power
30
2: ACC-25/50 with ACC-25/50DA(S), Requiring Greater than 50 Watts of Audio Power
30
3: ACC-25/50ZS & ACC-25/50ZST, Requiring up to 50 Watts of Audio Power
30
4: ACC-25/50ZS & ACC-25/50ZST, Requiring Greater than 50 Watts but Less than 150 Watts
31
Section 2: Field Programming
32
S1 DIP Switch Settings on ACC-25/50 Series Motherboard (ACC-MCB)
36
S5 DIP Switch Settings on ACC-25/50 Series Motherboard (ACC-MCB)
37
S3 DIP Switch Settings on ACC-25/50 Motherboard (ACC-MCB)
37
S2 - Record Bypass Switch on ACC-25/50 Series Motherboard (ACC-MCB)
38
S4 - Battery Charger Switch on ACC-25/50 Series Motherboard
39
SW1 - Remote Microphone Installed Switch on ACC-FFT
39
SW2 - 2 Wire/4 Wire Connection on Telephone Loop
39
ACC-ZPMK Zone Page Module (ACC-25/50ZS & ACC-25/50ZST)
39
1: S1 DIP Switch Settings on ACC-ZPMK
40
2: S2 and S3 Addressing Rotary Switches
41
ACC-ZSM Zone Splitter Module (ACC-25/50ZS & ACC-25/50ZST)
41
Section 3: Installation
42
Mounting Options
42
Backbox Installation
42
1: Transformer Installation
45
Operating Power
46
Auxiliary DC Power Output Connections
48
Input/Initiating Circuits
48
Output Circuits
49
1: Master Command Bus Output
49
2: Trouble Relay - TB1
51
3: AC Power Loss Relay - TB7
51
4: Notification Appliance Circuit (Speakers)
51
5: ACC-ZPMK Zone Page Module - ACS Link (ACC-25/50ZS & ACC-25/50ZST)
52
6: ACC-ZSM Zone Splitter Module (ACC-25/50ZS & ACC-25/50ZST)
54
7: ACC-FFT Fire Fighter Telephone Module (ACC-25/50ZST Only)
55
UL Power-Limited Wiring Requirements
56
Installation of Option Modules
57
1: Audio Amplifier Module (ACC-AAM25)
57
Transformer Module (FC-XRM70)
58
3: Local Playback Speaker Module (FC-LPS)
59
4: ACC-EPM External
60
Section 4: Operating Instructions
63
Switch Functions
63
1: Single Zone Operation (ACC-25/50, ACC-25/50ZS, ACC-25/50ZST)
63
2: Dual Zone Operation (ACC-25/50 Only)
63
3: Record/Playback
64
4: Trouble Silence
64
5: Record/Playback Button - Record Customized Messages
64
Recording Instructions
64
6: Record/Playback Button - Review Stored Message(S)
65
7: Main Control Panel Keypad Labels
66
ACC-ZPMK Switch Functions (ACC-25/50ZS & ACC-25/50ZST)
66
ACC-FFT Answer Call Push-Button (ACC-25/50ZST)
67
LED Indicators
67
1: Leds Visible with Backbox Door Closed (Figure
67
2: ACC-ZMPK Leds Visible with Backbox Door Closed (Figure
68
3: ACC-FFT Leds Visible with Backbox Door Closed (Figure
69
4: Leds Visible with Door Open and Optional Dress Panel Removed (Figure 1.1 & Figure 1.2)
69
Operation
70
1: Fire Alarm
70
2: Fire Alarm Restoral
70
3: Manual Evacuation/Alert
70
4: Manual Evacuation/Alert Restoral
71
5: Audio On/Off: ACC-25/50 Single Zone and ACC-25/50ZS/T
71
6: All Call: ACC-25/50, Single Zone Configuration
71
All-Call General Page Using Local Microphone
72
All-Call General Page Using Optional Remote Microphone
72
All-Call Emergency Page Using Local Microphone
72
All-Call Emergency Page Using Optional Remote Microphone
72
All-Call During FACP Activated Alarm
72
All-Call During Manual Evacuation/Alert
72
All-Call with Distributed Audio Panels
72
7: All-Call: ACC-25/50ZS & ACC-25/50ZST
72
All-Call General Page Using Local/Integral Microphone
72
All-Call General Page Using Optional Remote Microphone
73
All-Call General Page Using Optional RPJ-F Remote Keyswitch Via the Optional Fire Fighter Telephone Module
73
All-Call Emergency Page Using Local/Integral Microphone
73
All-Call Emergency Page Using Optional Remote Microphone
73
All-Call Emergency Page Using Optional RPJ-F Remote Keyswitch Via the Fire Fighter Telephone Module
73
All-Call During FACP Activated Alarm
73
All-Call During Manual Evacuation/Alert
73
8: Paging: ACC-25/50 Single Zone
73
General Page Using Local/Integral Microphone
73
General Page Using Optional Remote Microphone
73
Emergency Page Using Local/Integral Microphone
74
Emergency Page Using Optional Remote Microphone
74
9: Paging: ACC-25/50 Dual Zone
74
General Page Using Local/Integral Microphone
74
General Page Using Optional Remote Microphone
74
10: Paging: ACC-25/50ZS & ACC-25/50ZST
74
General Page Using Optional Remote Microphone
75
General Page Using the Optional RPJ-F Remote Keyswitch Via the Optional Fire Fighter Telephone Module
75
Emergency Page Using Local/Integral Microphone
75
Emergency Page Using Optional Remote Microphone
75
Emergency Page Using Optional RPJ-F Remote Keyswitch Via the Optional Fire Fighter Telephone Module
75
11: Fire Fighter Telephone: ACC-25/50ZST Only
75
Communication on the Telephone Loop
75
Annunciation of Remote Telephone Locations (MS-9600 or MS-9200UDLS Only)
76
12: Trouble Condition Response
76
13: Trouble Condition Restoral
78
Section 5: Application Examples
80
One Speaker Circuit on ACC-25/50
80
One Speaker Circuit with Backup on ACC-25/50
81
Two Speaker Circuits on ACC-25/50
83
Two Speaker Circuits on ACC-25/50
85
ACC-25/50ZS & ACC-25/50ZST Zone Splitting Applications
87
1: 25 Watt Zone Splitting - Eight Speaker Circuits, Style y (Class B)
87
2: 25 Watt Zone Splitting - Four Speaker Circuits, Style Z (Class A)
89
3: 50 Watt Zone Splitting - Eight Speaker Circuits
91
ACC-25/50 and ACC-25/50DA Installation
93
16 Theater Cineplex Utilizing ACC-25/50ZS with ACC-25/50DAZS
95
Audio Command Center 24 Zone System
96
Section 6: Power Supply Calculations
98
Overview
98
Calculating the AC Branch Circuit
98
Calculating the System Current Draw
98
2: How to Use Table 6.2 to Calculate System Current Draws
99
Calculating the Battery Size
100
1: NFPA Battery Requirements
100
2: Selecting and Locating Batteries
100
Appendix A: Digital Voice Messages
102
Appendix B: Addressable Module Connections
103
Appendix C: Wiring Requirements
104
Appendix D: Programmed Activation by FACP
105
D.1: MS-9600, MS-9200UDLS and MS-9200UD
106
D.1.1: Overview
106
D.1.2: Basic MS-9600/MS-9200UD/MS-9200UDLS & ACC-25/50ZS/T Step-By-Step Install/Setup
106
D.1.3: Wiring from ACC-25/50ZS or ACC-25/50ZST to FACP
107
D.1.4: ACC-25/50ZS and ACC-25/50ZST Switch Settings
108
D.1.5: FACP Programming
109
Programming Tips for MS-9600, MS-9600LD, MS-9200UDLS, and MS-9200UD
110
Message Assignment - Speaker Specific
110
Message Assignment - Zone Specific
112
Fire Fighter Telephone SLC Point Assignment
115
D.2.1: Overview
118
D.2.2: MS-5210UD Individual Zone Control with One or Two Messages
118
ACC-25/50ZS/T DIP Switch Settings
119
MS-5210UD Programming
120
D.2.3: MS-5210UD All Zone Activation with One to Five Messages
120
ACC-25/50ZS and ACC-25/50ZST Switch Settings
121
ACM-8RF Programming
121
MS-5210UD Programming
121
D.3.1: Overview
122
D.3.2: Basic MS-9200 & ACC-25/50ZS/T Step-By-Step Install/Setup
122
D.3.3: Wiring from ACC-25/50ZS or ACC-25/50ZST to MS-9200(E)
124
ACC-25/50ZS & ACC-25/50ZST Switch Settings
125
D.3.4: FACP Programming
125
D.4: MS-5UD-3/7 and MS-10UD-3/7
127
D.4.1: Overview
127
D.4.2: Basic ANN-BUS Step-By-Step Install/Setup
127
D.4.3: ACC-ZPMK DIP Switch 1 Settings on ACC-25/50ZS and ACC-25/50ZST
128
D.4.4: Wiring from ACC-25/50ZS or ACC-25/50ZST to FACP
129
D.4.5: FACP Programming
130
Index
138
Advertisement
Advertisement
Related Products
Honeywell Fire-Lite Alarms ACC-25/50
Honeywell Fire-Lite Alarms ACC-25/50ZST
Honeywell Accenta
Honeywell AQUATROL AQ25144B
Honeywell AQ25A42B
Honeywell AQ25A44B
Honeywell AQ25244B
Honeywell AQ2000 Series
Honeywell AQ25582B
Honeywell AQ25042B
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL