Sign In
Upload
Manuals
Brands
Hitachi Manuals
I/O Systems
HSC-2100
Hitachi HSC-2100 Manuals
Manuals and User Guides for Hitachi HSC-2100. We have
1
Hitachi HSC-2100 manual available for free PDF download: Hardware Manual
Hitachi HSC-2100 Hardware Manual (169 pages)
I/O Modules
Brand:
Hitachi
| Category:
I/O Systems
| Size: 1.55 MB
Table of Contents
Table of Contents
19
1 General Information
24
Features
25
Examples of Replacement
26
Model Number Correspondence between S10/2Α and S10/4Α Controllers' I/O Modules and HSC-2100 I/O Modules
29
Table 1-1 Model Number Correspondence between S10/2Α and S10/4Α
29
Controllers' I/O Modules and HSC-2100 I/O Modules
30
Before Using Pcs
31
2 Specifications of Individual Modules
38
Power Supply Modules
39
Table 2-1 Specifications of Power Supply Modules
39
Table 2-2 Names and Functions of Parts
39
Remote I/O Station Modules
40
Table 2-3 Instruction Manuals Giving the Specifications of Available Remote I/O
40
Table 2-4 Names and Functions of Parts (the Nos. below Are Keyed to those in the Rightmost Side of the Figure)
40
Mount Bases
41
Basic Mount Bases
41
Figure 2-3 Parts of the Model HSC-2104 Mount Base (Shown as Representative) and Their Names
41
Table 2-5 Available Basic Mount Base Models
41
Table 2-6 Parts of the Model HSC-2104 Mount Base (Shown as Representative)
42
Expansion Mount Bases
43
Figure 2-4 Parts of the Model HSC-2128 Expansion Mount Base
43
Table 2-7 Available Expansion Mount Base Models
43
Table 2-8 Parts of the Model HSC-2128 Expansion Mount Base (Shown as Representative)
44
Model LWI400 Input Module (12 to 24 VDC Input, 32 Points)
45
Model LWI450 Input Module (12 to 24 VDC Input, 16 Points)
46
Model LWI460 Input Module (48 VDC Input, 16 Points)
47
Model LWI470 Input Module (100 VDC Input, 16 Points)
48
Model LWI650 Input Module (100 to 120 VAC Contact Input, 16 Points)
50
Model LWO400 Output Module (100 to 200 VAC Contact Output, 32 Points)
51
Model LWO450 Output Module (100 to 200 VAC Contact Output, 16 Points)
52
Model LWO460 Output Module
53
Independent Common, 16 Points)
53
Model LWO610 Output Module
55
Points [Source])
55
Model LWO650 Output Module (12 to 24 VDC Transistor Output, 16 Points [Sink])
56
Model LWO670 Output Module (100 VAC Triac Output [With Fuse], 16 Points)
57
Model LWC400 Counter Module
58
Counting from 0 to 16,383)
58
Model LWC401 Counter Module
59
Counting from -8,192 to +8,191)
59
Model LWC402 Counter Module
60
Counting from -8,192 to +8,191)
60
Model LWA400 Input Module (±5 VDC Voltage Input, 4 Channels)
61
Model LWA401 Input Module (±5 VDC Voltage Input, 4 Channels)
62
Model LWA402 Input Module (±10 VDC Voltage Input, 4 Channels)
63
Model LWA403 Input Module (±10 VDC Voltage Input, 4 Channels)
64
Model LWA404 Input Module (±5 VDC Voltage Input, 2 Channels)
65
Model LWA421 Input Module (RTD Input, 4 Channels)
66
Model LWA422 Input Module (RTD Input, 4 Channels)
67
Model LWA423 Input Module (RTD Input, 4 Channels)
68
Model LWA430 Input Module (±5 VDC Voltage Input, 4 Channels)
69
Model LWA435 Input Module (±5 VDC Voltage Input, 4 Channels)
70
Model LWA500 Input Module (±10 VDC Voltage Input, 8 Channels)
71
Model LWA501 Input Module (±5 VDC Voltage Input, 8 Channels)
72
Model LWA450 Output Module (±5 VDC Voltage Output, 4 Channels)
73
Model LWA460 Output Module (4 to 20 Ma DC Current Output, 4 Channels)
74
3 Installation and Module Mounting
78
Where to Install
79
Figure 3-1 an Installed Programmable Controller
79
Installation Environment
80
Table 3-1 Installation Environment Specifications
80
Installation Styles
81
Concentrated Installation
81
Figure 3-2 an Example of Concentrated Installation
81
Dispersed Installation
82
Figure 3-3 an Example of Dispersed Installation
82
Installation Clearances
85
Figure 3-4 Installation Clearances
85
External Dimensions
86
Figure 3-5 External Dimensions
86
Installing a Mount Base and Mounting a Module on It
87
Installing a Terminal Block
88
Mounting Design
90
Mounting Limitations
90
Module Mounting
91
4 Wiring
92
Solderless Terminals
93
Figure 4-1 Connecting Cable Wires and Solderless Terminal Together
93
Wiring for the Power Supply
94
Figure 4-2 an Example of Power Supply Wiring with an
94
Figure 4-3 an Example of Power Supply Wiring with an Isolation Transformer Mounted in the Programmable Controller Cubicle
95
Figure 4-4 an Example of Wiring in the Cubicle
96
Ground Wiring
97
Figure 4-5 an Example of Ground-Wiring in a Concentrated Installation
97
Figure 4-6 an Example of Ground-Wiring in a Dispersed Installation
98
Wiring the Remote I/O Cable
99
Wiring I/O Modules
99
Wiring a Pulse Counter Module
100
5 Making Use of Modules
102
Using Digital I/O Modules
103
Using Digital Input Modules
103
Using LWO400, LWO450, and LWO460 Contact Output Modules
103
Figure 5-1 Connecting a Special Resistor to an
103
Figure 5-2 Surge Absorber Circuits
103
Using Transistor and Triac Output Modules
104
Checking the Operation Indicator Leds
105
Figure 5-3 Checking the Operation Indicator Leds
105
Using Analog Input/Output Modules
106
Transferring Data to or from Analog Modules
106
Registering Data Areas
106
Table 5-1 Software Tools Used for the Registration of Data Areas
106
Table 5-2 Available Registration Numbers and the Corresponding Data Areas
107
Table 5-3 the Registration Model Numbers for Analog I/O and Counter Modules
107
Data Area Formats
108
Data Areas for 8-Channel Analog Input/Output Modules
111
Data Formats of 8-Channel Analog Input/Output Modules
111
Using Pulse Counter Modules
114
Available Functions
114
How to Use Pulse Counter Modules
117
Figure 5-4 Operational Chart
121
Figure 5-5 the Contents of the Example Program
122
Table 5-4 the Status of Pulse Counter Modules Upon Power-On
123
Table 5-5 the Status of Pulse Counter Modules During Stop State of
123
Table 5-6 the Status of Pulse Counter Modules (in I/O Units) Upon
124
Registration in the Analog Support Program
125
An Example of Registration in the Analog Support Program
126
Figure 5-6 an Example Hardware Configuration in Which Four Modules Are Mounted
126
Ladder Program Conversion at the Replacement of S10/4Α I/O Modules
133
Items Necessary for Ladder Program Conversion Work
133
Saving the Ladder Program
134
Converting the Ladder Program
139
Sending the Ladder Program
147
6 Maintenance
150
Preventive Maintenance
151
Table 6-1 Inspection Items
151
Figure 6-1 the Power Supply Module's Check Terminals
152
Troubleshooting
154
Figure 6-2 an I/O Unit (4-Slot Mount Base) and the Locations of the Operation Indicators
154
Troubleshooting the Power Supply and Remote I/O Station Modules
155
Troubleshooting the Remote I/O Station Module
155
Troubleshooting a Digital Input Module
156
Troubleshooting a Digital Output Module
157
Troubleshooting an Analog Input Module
159
Troubleshooting an Analog Output Module
160
Troubleshooting a Pulse Counter Module
161
7 Appendix
164
Pt100 Resistance Vs. Temperature Table
165
Jpt100 Resistance Vs. Temperature Table
167
Advertisement
Advertisement
Related Products
Hitachi HS2160EIO61H
Hitachi H8S/2160B Series
Hitachi HX-RIO3 Series
Hitachi HX-RIO3-AY V Series
Hitachi Living Systems HSTM300SS
Hitachi HS20-T
Hitachi HS25-T
Hitachi HS50-T
Hitachi H Series
Hitachi HS50
Hitachi Categories
Projector
Air Conditioner
Drill
Power Tool
TV
More Hitachi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL