HISTORY INFORMATION FOR THE FOLLOWING MANUAL: DA-4 SERVICE MANUAL CHASSIS MODEL NAME REMOTE COMMANDER DESTINATION CHASSIS NO. KV-27HS420 RM-Y197 SCC-S76C-A KV-27HS420 RM-Y197 CANADA SCC-S70X-A KV-29DRC430 RM-Y197 LATIN NORTH SCC-S71S-A KV-29DRC430 RM-Y197 LATIN SOUTH SCC-S71T-A KV-30HS420 RM-Y197 SCC-S76D-A KV-30HS420 RM-Y197 CANADA SCC-S70Y-A KV-30HS420 RM-Y197...
Page 2
Self Diagnosis Supported model DA-4 SERVICE MANUAL CHASSIS MODEL NAME REMOTE COMMANDER DESTINATION CHASSIS NO. KV-27HS420 RM-Y197 SCC-S76C-A KV-27HS420 RM-Y197 CANADA SCC-S70X-A KV-29DRC430 RM-Y197 LATIN NORTH SCC-S71S-A KV-29DRC430 RM-Y197 LATIN SOUTH SCC-S71T-A KV-30HS420 RM-Y197 SCC-S76D-A KV-30HS420 RM-Y197 CANADA SCC-S70Y-A KV-30HS420 RM-Y197 HAWAII SCC-S69R-A...
High-Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing LLC. Wega, FD Trinitron, Steady Sound, Digital Reality Creation, Cap- tion Vision, and CineMotion are registered trademarks of Sony Corporation. ClearEdge VM and HD Detailer are trademarks of Sony Corporation.
Ne les remplacer que par des composants Sony dont le numero de piece est indique dans le present manuel ou dans des supplements publies par Sony. Les reglages de circuit dont l’importance est critique pour la securite du fonctionnement sont identifi...
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 SAFETY CHECK-OUT Leakage Test After correcting the original service problem, perform the following The AC leakage from any exposed metal part to earth ground and from safety checks before releasing the set to the customer: all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes).
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 Self Diagnosis SELF-DIAGNOSTIC FUNCTION Supported model The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the instruction manual for the user’s knowledge and reference.
Page 9
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 Self-Diagnostic Screen Display For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confi rmed, it is possible to bring up past occurrences of failure on the screen for confi rmation. To Bring Up Screen Test In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below: DISPLAY...
Page 10
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 +B overcurrent (OCP) Occurs when excessive current fl ows through R5013. The increase in voltage across R5013 causes the output of Q5004 to go high, and this high signal goes to the micro. +B overvoltage (OVP) IC6505 detects +B OVP condition and turns on Q6522. This sends a high signal to the micro and also shuts down the AC relay. V-STOP Occurs when an absence of the vertical defl...
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 1-4. PICTURE TUBE REMOVAL WARNING: BEFORE REMOVING THE ANODE CAP High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, Coated discharge CRT before attempting to remove the anode cap. Short between anode and CRT Earth Ground coated earth ground strap.
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 CABLE WIRE DRESSING NOTE: IF THE WIRE DRESSING IS NOT DONE PROPERLY, IT MAY CAUSE DISTORTION G2 & FOCUS LEAD WIRE DRESSING [CH] [CX] CLP9003 CRT SOCKET CN9109 CN9003 CN9004 Push Wire Down CLP9002 HERE FOCUS LEAD Dress wires in Clamp on U-Bracket SIDE VIEW...
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 G2 WIRE ROUTING CAUTION POINT G2 WIRE 1-900-808-42 REV-1 REAR VIEW 3/11/05 Dress wire in “L” Shape. U-Bracket O.K. CONDITION N.G CONDITION SIDE VIEW SIDE VIEW Wire Holder N.G! p/n: 4-065-850-11 Wire can touch Wire Holder Rear Cover!! p/n: 4-065-850-11 G2 Wire MUST be routed correctly so that the wire does NOT touch Rear Cover (Causes “Buzzing”...
Page 15
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 KV-27HS420/29DRC430/32HS420 ECG WIRE DRESSING (Earth Coating Ground) Caution Points: 1. Make sure braided ECG wire loop does not twist, and stays flat on CRT surface. 2. Do not pull excessively on the tension spring NOTE2: There are NOTE: Leads are 3.
Page 16
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 KV-30HS420/34HS420 ECG WIRE DRESSING NOTE2: There are 2 Leads (TOTAL 4 Wires) to connect to CX-Board 2-022-978-01 Wire Clip (2 Places) NOTE: Leads are dressed inside Rotation Coil. Rotation COIL SPRING (2 places) Integral part of the Ground wire ECG - P/N 1-900-808-30 - 30 WCRT 1-900-808-31 - 34W CRT...
Page 17
KV-27HS420/29DRC430/30HS420/32HS420/34HS420 ECG ASSEMBLY CAUTION POINTS CRT Frit-Line CRT Frit-Line FRONT FRONT Make sure braided Make sure braided wire does not twist or wire does not twist or SPEAKER sag on CRT surface. sag on CRT surface. SPEAKER Caution: Caution: Clip spring on Clip spring on the OUTSIDE the OUTSIDE...