CONTROLS & ELECTRONICS CONFIGURATION Product Configuration No frost Dlx Product Control RC Controlled Software BEE/Pot based Professional User interface Auto cool mode Ice accelerator Auto Power save mode Door Alarm Power supply for illumination DC (Linear 220mA) RC Illumination (8 LED) FC Illumination (2 LED) Control Board Yes(Nilgiri BEE)
Page 8
Top Mount : Deluxe models: ------------------- This refrigerator is managed by an Electronic System, mainly consisting of the components: Electronic Control Board (Nilgiri- Dlx (BEE)) • POT (Potentiometer) in case of Dlx (BEE) models only. • Temperature Sensors {refrigerator, Defrost & POT(Dlx)} •...
Page 11
Refrigerant Charging Qty: Model Refrigerant R134a(gms) 410L Dlx 445L Dlx CN1 (Connector 1) – Compressor, Heater and Power Cord CN2 (Connector 2) – RC/FC LED, Load component and Temperature Sensors/POT CN3 (Connector 3) – User Interface board (Used only for Elite models) WARNING Electrostatic Discharge Risk Do not touch the Circuit components, because you can damage fuse/burned or weaken the...
Page 12
3. Release the Cover tabs. 4. Releasing the On board Connectors. IMPORTANT # Be careful when using the Multimeter measuring probes, as they may damage the Connector terminals. # Be careful when removing the electronic board connectors, as they are latched. Remove them at right angles with no side movements...
Page 13
1. Defrost Sensor mounted on the Evaporator tube. 2. Removing/Replacing the Defrost Sensor Defrost Temperature Sensor – NTC It’s located at the freezer compartment, along with the Evaporator. The Defrost Sensor is responsible for sending signals to the electronic control, which will command the ending of the defrost, turning off the Defrost Heater, This does a similar function to the well-known Defrost Bimetal IMPORTANT...
Dlx models:- Adaptive Defrost Control The defrost cycle shall be started after the Defrost timer has expired. According to the following defrost procedure: Defrost must be executed every time one of the following event occurs: 1. After 8 hours (+/-10 minutes) of compressor running, calculated considering just the thermostat function.
Page 15
Door Open Sensing Alarm Door open sensing alarm activates or gives beep if the door is kept open for more than 2 min. During the Door opening beep alarm if the door is closed then the alarm gets deactivated Alarm Codes, Priority, Retention and Trigger Alarm code for Deluxe models: - •...
Page 16
Note: - • There is no Service routine provided in this model. • In Dlx models Diagnosis of the Error / Sensor / Pot failure is not of continuous nature. Service person needs to restart the Product to listen to the Buzzer Beep for error indications if any. •...
PART LIST FOR ONYX-AUSTRALIA SL.NO PART NO. DESCRIPTION A2242782000 CAP, TOP HINGE COVER WHITE- ONYX 1 A2242785500 CAP, TOP HINGE COVER METALON- ONYX 1 A2240872000 TOP HINGE COVER RH-ONYX,WHITE 1 A2240875500 TOP HINGE COVER RH-ONYX,METALON 1 A2243510000 SELF TAP SCREW M 5.5 x 1.8 4 A2242600000 SUB ASSY,TOP HINGE-ONYX 1 A2242332000...
Page 24
A2240700000 SUB ASSY,CRISPER COVER - ONYX 1 A224044000A VEG CRISPER 1 A224133000A FC GRILL - ONYX 1 A2242230000 COMPLEMENT,VEG CRISPER COVER- ONYX 1 A2241102000 COVER,CENTRE RAIL NON HINGE WHITE - ONYX 1 A2241105500 COVER,CENTRE RAIL NON HINGE METALON - ONYX 1 A2243490000 M 4.8X 13 SELF TAPPING SCREW(LINER TO PLENUM) 4 A2242690000...
Page 25
A224328000A DIFFUSER EPS SUB ASSY,410L - ONYX 1 A2250430000 SCREW FOR FIXING COVER AIR DIFFUSER ASSY TO LINER , 450L 3 A2250430000 SCREW FOR FIXING COVER AIR DIFFUSER ASSY TO LINER , 410L 2 A224167000A CABINET SPACER-ONYX 2 A224142000B COMPRESSOR BASE PLATE ASSY-ONYX 1 A2260560000 COMPRESSOR EGZS 80HLC ( 513701040 ) - ONYX 1 A2243930000...
Page 26
A2290700000 CORE BOARD BOX COVER 1 A2243480000 M4.8 X 0.8 SELF TAPPING SCREW (CONTROL BOARD TO WRAPPER) 2 A2117510000 THERMAL FUSE WITH CONNECTOR 1 A2290920000 FC THERMISTOR CLIP 1 A2242050000 HARNESS, FC THERMISTOR 1 A2243610000 SS WASHER DOOR STOPPER 1 A2241780000 Defrost Heater WRID...