Air-Conditioners
PKA-RP·FAL
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner
unit.
FOR INSTALLER
English

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PKA-RP-FAL

  • Page 1 Air-Conditioners PKA-RP·FAL INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
  • Page 2: Table Of Contents

    • The terminal block cover panel of the unit must be firmly attached. rectly installed unit may fall down and cause damage or injuries. • Use only accessories authorized by Mitsubishi Electric and ask a dealer or • The unit must be securely installed on a structure that can sustain its weight.
  • Page 3: Installation Location

    2. Installation location 2.1. Outline dimensions (Indoor unit) (Fig. 2-1) Select a proper position allowing the following clearances for installation and mainte- nance. (mm) Models RP2.5, 3 1400 Min. 150 Min. 50 Min. 30 Min. 250 Min. 150 1680 Min. 150 Min.
  • Page 4 3. Installing the indoor unit 1 RP2.5, RP3 3) Installing the wall mounting fixture s Since the indoor unit weighs near 30 kg, selection of the mounting location requires thorough consideration. If the wall does not seem to be strong enough, reinforce it with boards or beams before installation.
  • Page 5: Installing The Refrigerant Piping

    3. Installing the indoor unit 3.4. Mounting the indoor unit (Fig. 3-11) 1 Make sure to hang the metal catches of the indoor unit over the hooks of the wall mounting fixture. 2 When the piping has been completed, use the securing screws to fix the indoor unit on the wall mounting fixture.
  • Page 6: Drainage Piping Work (Fig. 5-1)

    4. Installing the refrigerant piping 4.3. Refrigerant piping (Fig. 4-5) Liquid pipe 1) Indoor unit Caution: Before connecting right, lower, left or left rear piping, connect the supplied L- Band (large) 4 shaped connection pipe B to the on-site piping. Insulation material 3 When using commercially available copper pipes: Refrigerant and Drainage Piping Sizes...
  • Page 7 6. Electrical work 6-2 Installing the wireless remote controller 1) Installation area • Area in which the remote controller is not exposed to direct sunshine. MODEL SELECT • Area in which there is no nearby heating source. • Area in which the remote controller is not exposed to cold (or hot) winds. •...
  • Page 8: Test Run

    6. Electrical work Function table Select unit number 00 Mode no. Setting no. Initial setting setting Mode Settings Power failure automatic recovery Not available Available Indoor temperature detecting Indoor unit operating average Set by indoor unit’s remote controller – Remote controller’s internal sensor LOSSNAY connectivity Not Supported Supported (indoor unit is not equipped with outdoor-air intake)
  • Page 9 7. Test run • For description of each check code, refer to the following table. 1 Check code Symptom 2 Buzzer sound 3 OPE LED Single beep × 1 Lit for 1 sec. × 1 Intake sensor error Single beep × 2 Lit for 1 sec.
  • Page 10 336/ EEC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Printed in Japan BG79U167H01...