SERVICING NOTICES ON CHECKING 1. KEEP THE NOTICES 6. AVOID AN X-RAY As for the places which need special attentions, Safety is secured against an X-ray by consider- they are indicated with the labels or seals on the ing about the cathode-ray tube and the high cabinet, chassis and parts.
TABLE OF CONTENTS SERVICING NOTICES ON CHECKING ..................A1-1 A1-1 HOW TO ORDER PARTS ......................IMPORTANT ..........................A1-1 TABLE OF CONTENTS ......................A2-1 A3-1~A3-5 GENERAL SPECIFICATIONS ....................DISASSEMBLY INSTRUCTIONS 1. REMOVAL OF ANODE CAP ....................B1-1 2. REMOVAL AND INSTALLATION OF FLAT PACKAGE IC ..........B2-1, B2-2 SERVICE MODE LIST ........................
GENERAL SPECIFICATIONS CRT Size / Visual Size 13 inch / 335.4mmV System CRT Type Normal Deflection degree Magnetic Field BV/BH +0.45G/0.18G Color System NTSC Speaker 1Speaker Position Bottom Size 3 Inch Impedance Sound Output 1.0 W 10%(Typical) 0.8 W NTSC3.58+4.43 /PAL60Hz Tuning Broadcasting System System M...
Page 5
GENERAL SPECIFICATIONS On Screen Menu Display Menu Type Character Picture Contrast Brightness Color Tint Sharpness Audio Bass Treble Balance BBE On/Off Stable Sound On/Off CH Set Up TV/CABLE(CATV) Auto CH Memory Add/ Delete Language V-chip Lock On Timer CH Label Favorite CH Color Stream DVD/DTV Control Level...
Page 6
GENERAL SPECIFICATIONS G-10 Remote Unit RC-EH Control Glow in Dark Remocon Format Toshiba Custom Code 40-BF h Power Source Voltage(D.C) UM size x pcs UM-4 x 2 pcs Total Keys Keys Keys Power CH Up CH Down Volume Up Volume Down...
Page 7
GENERAL SPECIFICATIONS G-11 Features Auto Degauss Auto Shut Off Canal+ CATV Anti-theft Rental Memory(Last CH) Memory(Last Volume) V-Chip Type USA,ORION Type Auto Search CH Allocation Channel Lock Just Clock Function Game Position CH Label VM Circuit Full OSD Premiere Comb Filter Lines Auto CH Memory Hotel Lock...
Page 8
GENERAL SPECIFICATIONS G-13 Interface Switch Front Power System Select Main Power SW Sub Power Channel Up/Reset Channel Down/Enter Volume Up/Set Up Volume Down/Set Down MENU=Volume Up+Volume Down Rear AC/DC TV/CATV Selector Degauss Main Power SW Indicator Power Stand-by On Timer Terminals Front Video Input...
DISASSEMBLY INSTRUCTIONS 3. After one side is removed, pull in the opposite direction to 1. REMOVAL OF ANODE CAP remove the other. Read the following NOTED items before starting work. NOTE After turning the power off there might still be a potential Take care not to damage the Rubber Cap.
DISASSEMBLY INSTRUCTIONS When IC starts moving back and forth easily after REMOVAL AND INSTALLATION OF desoldering completely, pickup the corner of the IC using a FLAT PACKAGE IC tweezers and remove the IC by moving with the IC desoldering machine. (Refer to Fig. 2-3.) REMOVAL NOTE Put the Masking Tape (cotton tape) around the Flat...
Page 11
DISASSEMBLY INSTRUCTIONS INSTALLATION When bridge-soldering between terminals and/or the soldering amount are not enough, resolder using a Thin-tip Take care of the polarity of new IC and then install the new Soldering Iron. (Refer to Fig. 2-8.) IC fitting on the printed circuit pattern. Then solder each lead on the diagonal positions of IC temporarily.
SERVICE MODE LIST This unit provided with the following SERVICE MODES so you can repair, examine and adjust easily. To enter the Service Mode, press both set key and remote control key for more than 1 second. Set Key Remocon Key Operations Releasing of V-CHIP PASSWORD and LOCK PASSWORD.
ELECTRICAL ADJUSTMENTS 1. ADJUSTMENT PROCEDURE 2. BASIC ADJUSTMENTS Read and perform these adjustments when repairing the 2-1: CUT OFF circuits or replacing electrical parts or PCB assemblies. Adjust the unit to the following settings. CAUTION R.DRIVE=10, B.DRIVE=10, R.BIAS=64, G.BIAS=64, • Use an isolation transformer when performing any service B.BIAS=64, BRI.CENT=120, CONT.MAX=40.
Page 14
ELECTRICAL ADJUSTMENTS 2-6: VERTICAL SIZE Receive the monoscope pattern. Using the remote control, set the brightness and contrast to normal position. Activate the adjustment mode display of Fig. 1-1 and press the channel button (06) on the remote control to select “V.
ELECTRICAL ADJUSTMENTS 3. PURITY AND CONVERGENCE 3-3: STATIC CONVERGENCE ADJUSTMENTS NOTE Adjust after performing adjustments in section 3-2. NOTE Receive the crosshatch pattern from the color bar Turn the unit on and let it warm up for at least 30 generator.
Page 16
ELECTRICAL ADJUSTMENTS 4. ELECTRICAL ADJUSTMENT PARTS LOCATION GUIDE (WIRING CONNECTION) S101 CRT PCB CP806 TP022 TU001 CP803A TP023 FB401 CP802B CP801 DEGAUSS COIL T502 CP502 S501B CD501 AC IN S501A CD101B SPEAKER CD101A MAIN PCB...
BLOCK DIAGRAM TU001 EAR PHONE_JACK 11 12 J1001 CH. DOWN IC1001 AN7511 VOL. DOWN SPEAKER SOUND AMP SP1001 CH. UP VOL. UP RGB Proc.2 Q801 OSD SW CONTRAST BRIGHTNESS RED OUT RGB OUTPUT Stage POWER DRIVE Chroma Q802 Proc. CUT OFF ACC/C-BPF OS101 GREEN OUT...
Page 21
TV POWER SCHEMATIC DIAGRAM (MAIN PCB) 4A 125V CAUTION :FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE 4A 125V (F501) TO SOUND/AV FUSE. ATTENTION :POUR UNE PROTECTION CONTINUE LES RISQUES D’INCEIE N’UTILISER QUE DES FUSIBLE DE MEME R517_1 TYPE 4A 125V (F501).
WAVEFORMS MICON/CHROMA/TUNER 5 1V 20µs/div 9 20V 20µs/div 1 0.5V 2ms/div 6 1V 20µs/div 20V 20µs/div 10 2V 20µs/div 200V 20µs/div 3 200mV 20µs/div 1V 20µs/div DEFLECTION/CRT 10V 5ms/div 0.5V 5ms/div 8 0.5V 5ms/div NOTE: The following waveforms were measured at the point of the corresponding balloon number in the schematic diagram.
WAVEFORMS SOUND/AV 0.5V 1ms/div 10V 5ms/div 50V 20µs/div 1V 1ms/div 200mV 500µs/div 15 50V 20µs/div 16 50V 20µs/div 20 500mV 20µs/div NOTE: The following waveforms were measured at the point of the corresponding balloon number in the schematic diagram.