hit counter script
JVC LST0601-001B Startup Manual
JVC LST0601-001B Startup Manual

JVC LST0601-001B Startup Manual

Jvc network video recorder start up guide

Advertisement

Quick Links

NETWORK VIDEO RECORDER
VR-N1600U
VR-N1600E
OPERATE
REC CONTROL
Please read the following before getting started:
Thank you for purchasing this JVC product.
Before operating this unit, please read the instructions
carefully to ensure the best possible performance.
For Customer Use:
Enter below the Serial No. which is located on the
body.
Retain this information for future reference.
Model No.
Serial No.
\
LIVE/BROWSE
SELECT
PTZ/PRESET
SERIAL
CANCEL
ZOOM OUT
ZOOM IN
VR-N1600U
WARNING
ALARM
HDD
LOCK
FUNCTION
SEARCH
KEY
ALARM CLEAR
REC/STOP
STARTUP GUIDE
REV
STOP(PB)
PLAY
Powered by Milestone
(A)
FWD
SKIP
LST0601-001B

Advertisement

Table of Contents
loading

Summary of Contents for JVC LST0601-001B

  • Page 1 PTZ/PRESET SERIAL CANCEL Please read the following before getting started: Thank you for purchasing this JVC product. Before operating this unit, please read the instructions carefully to ensure the best possible performance. For Customer Use: Enter below the Serial No. which is located on the body.
  • Page 2 IMPORTANT SAFEGUARDS...
  • Page 3 SAFETY PRECAUTIONS (for USA)
  • Page 4 SAFETY PRECAUTIONS (for Europe)
  • Page 6 SICHERHEITSVORKEHRUNGEN (for Germany)
  • Page 8 SICHERHEITSVORKEHRUNGEN (for Germany)
  • Page 9 1600E 1600E VIII...
  • Page 10: Getting Started

    Page or item to refer to. Content of this Manual ● The copyright of this manual belongs to JVC. Reproduction or copy of this manual, in part or in whole, without the prior consent of JVC is strictly prohibited.
  • Page 11: Table Of Contents

    Contents Getting Started Features ... 2 Contents ... 3 Precautions for Proper Use of this Product ... 4 Part Names and Functions ... 6 Mounting to a Rack ... 10 Preparation System Connection Example ... 11 During Initial Startup ... 12 Basic Operation Viewing Live Images via Front Panel Control ...
  • Page 12: Precautions For Proper Use Of This Product

    HDD may affect its subsequent use even when the UPS is connected. JVC shall not be held responsible for the compensation of losses incurred in the event that recording or playback fails due to defects in this unit or its hard disk drive.
  • Page 13 The condition may also be improved by adjusting this unit. For details, consult your nearest JVC dealer. This unit comes with a high-precision hard disk device. Be careful not to exert vibration or impact on this unit when handling it.
  • Page 14: Part Names And Functions

    Getting Started Part Names and Functions Front LIVE/BROWSE OPERATE SELECT REC CONTROL PTZ/PRESET SERIAL CANCEL [OPERATE] Button/Indicator Switches operation on or off. Press the button to turn operation AONB and hold down the button to turn operation AOFFB. The indicator blinks while the recorder is starting up or shutting down. [REC CONTROL] Button/Indicator Switches the recording control mode on or off.
  • Page 15 When in the recording control mode, press and hold this button to exit the recording control mode. Memo : ● The manual recording mode executes recording from all cameras regardless of the settings in the [Camera Record Setting]. Recording is carried out in accordance with the frame rate selected in [Camera Record Setting].
  • Page 16 Getting Started Part Names and Functions (continued) Rear Panel POWER [POWER] switch Switches the power on or off. Memo : ● Be sure to press and hold down the [OPERATE] button on the front panel to shut down the system before switching off the power supply.
  • Page 17 Rear I/O Terminals Input ports [ALARM IN 1 to 8] alarm input terminals 1 to 8 Alarm recording is activated when signals are input to these terminals. [EMERGENCY] emergency input terminal Recording is activated in all cameras when a signal is input to this terminal.
  • Page 18: Mounting To A Rack

    Getting Started Part Names and Functions (continued) Rear I/O Terminals Terminal e[ALARM 250 ms 250 ms and above and above Make Memo : ● Set the impedance at the output end to 10kK or below. f[EMER- GENCY] g[ALARM RESET] 250 ms and above Memo : ●...
  • Page 19: Preparation

    Preparation System Connection Example The following operations are possible with this system. ● Surveillance (live image, recording and playback) by connecting up to 16 cameras ● Checking recorded images on the VGA monitor ● Recording/Playing sound ● Alarm recording ● Remote surveillance using PCs Supplied power cable VGA monitor IP cameras...
  • Page 20: During Initial Startup

    Preparation System Connection Example (continued) Note : ● Do not connect LAN1 to the internet. If the internet is busy or the relay equipment fails, you may not be able to save important camera images. To maintain full recording capacity, it is recommended that a dedicated network be used.
  • Page 21 Selecting a Language The [Language Setting] screen appears when you start up VR-N1600U/E for the first time. Select the language to use using the steps below. Select a language ● Use the [2/D] or [10/0/E] button to select a language. Use the [SKIP] button to select [OK], followed by pressing the [16/ENTER] button ●...
  • Page 22 Preparation During Initial Startup (continued) Use the [SKIP] button to select [OK], followed by pressing the [16/ENTER] button ● The [Configure Device] screen appears. Enter the password for the network camera ● Press the [KEY] button to display the software keyboard.
  • Page 23 Use the [7/B] button to display the camera Use the [10/0/E] button to select a camera Use the [SKIP] button to select [Settings...], followed by pressing the [16/ENTER] button ● The [Camera Settings] screen appears. Speedup Settings Recording Settings Setting the Live Image Display Rate ●...
  • Page 24: Basic Operation

    Basic Operation Viewing Live Images via Front Panel Control This section describes the procedures for viewing live images by using the front panel of VR-N1600U/E. [Live] Screen Displaying the [Live] Screen Press the [LIVE/BROWSE] button when the wallpaper *1 or main menu *2 screen is displayed.
  • Page 25: Operating The Camera

    Memo : Event indicator (Left: yellow) Lights up when events specified in the [Camera Record Setting] occur. The indicator appears black if event indication has not been specified for the camera in question, or if no specified event has occurred. Motion indicator (Center: red) Lights up when motion is detected.
  • Page 26: Playing Back Recorded Images Via Front Panel Control

    Basic Operation Playing Back Recorded Images via Front Panel Control This section describes the procedures for playing back recorded images using the front panel of VR-N1600U/E. Displaying the [Browse] Screen Press the [LIVE/BROWSE] button when the wallpaper or main menu screen is displayed ●...
  • Page 27: Adjusting The Playback Speed (Jog/Shuttle Playback)

    Playing Back Press the [PLAY] button ● Playback starts from the date/time indicated in [Master Time] of [Time Navigation]. ● Images are played back according to the angle of the shuttle dial (x1/20, x1/5, x1, x2, x5, x10, x20). [Master Time] area NVR Viewer [Browse] Screen [Go To] Button...
  • Page 28: Others

    Action to Take If this message is displayed for the D drive, try to recover using HDD Utility. If the above does not solve the problem, consult your nearest JVC dealer. The HDD seems is no longer serviceable. Replacement is recommended.
  • Page 29: Specifications

    Specifications General Allowable Operating Temperature : 5 I to 40 I Allowable Storage Temperature : -20 I to 60 I Allowable Operating Humidity : 30 % to 80 % Power Supply VR-N1600U : AC 120 V, 50 Hz/60 Hz VR-N1600E : AC 220 V to 240 V, 50 Hz/60 Hz Consumption Current VR-N1600U : 1.2 A(max.) VR-N1600E : 0.8 A(max.)
  • Page 32 © 2009 Victor Company of Japan, Limited LST0601-001B...

This manual is also suitable for:

Vr-n1600uVr-n1600e

Table of Contents