27-9
Purpose
Setting
Function (Purpose) Used to set the threshold value for deter-
mining whether the paper feed time
between sensors is recorded or not and the
threshold value for determining whether the
gain adjustment retry number is recorded
or not.
Section
Item
Specifications
Operation/Procedure
1)
When the machine enters the simulation, the following screen
is displayed.
2)
Select an item to be set with [↑] and [↓] buttons.
The highlighted section of the set value is changed and the
value is displayed in the setting area.
* When there is an item over [↑], the display becomes active
and shifts to another item.
When there is no item over [↑], the display grays out and the
operation is disabled.
When there is an item under [↓], the display becomes active
and shifts to another item.
When there is no item under [↓], the display grays out and
the operation is disabled.
3)
Enter the set value with 10-key.
* Press [C] key to clear the entered value.
4)
When [OK] button is pressed, the current set value is saved to
EEPROM and RAM.
After completion of setting, [OK] button returns to the normal
display.
* When [COLOR], or [BLACK] key is pressed, the current set
value is saved to EEPROM and RAM.
<Setting range and default value of each value>
Item
Display
A
FEED TIME1
Threshold value of paper
feed time between sensors
(Main unit)
B
FEED TIME2
Threshold value of paper
feed time between sensors
(SPF)
C
GAIN
Threshold value of gain
ADJUSTMENT
adjustment retry number
RETRY
D
JAM ALERT
Threshold value of
continuous JAM alert
judgment
* Item A: 0% is the standard passing time between sheets. 100%
is the time for judgment as a JAM between sheets.
SIMULATION NO.27-09
TEST
FSS FUNCTION ADJUSTMENT
A
50
FEED TIME1
A:
50
B
50
FEED TIME2
0 100
C
50
GAIN ADJUSTMENT RETRY
D
50
JAM ALERT
Setting
Default
Content
range
value
0 to 100
50 (%)
0 to 100
50 (%)
1 to 100
50
(TIMES)
1 to 100
10
(TIMES)
CLOSE
MX3500N SIMULATION 7 – 42
27-10
Purpose
Function (Purpose) Used to clear the trouble prediction history
Section
Item
Operation/Procedure
1)
Press [EXECUTE] button.
[EXECUTE] button is highlighted, and [YES] and [NO] buttons
become active display.
2)
Press [YES] button.
The history information of the trouble prediction information is
cleared. [YES] button is highlighted.
* When [NO] button or [EXECUTE] button is pressed, [EXE-
CUTE] button returns to the normal display and [YES] and
[NO] buttons gray out.
* After completion of the trouble prediction information history
clear, [EXECUTE] button returns to the normal display and
[YES] and [NO] buttons gray out.
<Clear target history item>
Serial communication retry number history
High density process control error history
Half tone process control error history
Automatic register adjustment error history
Gain adjustment retry history
Paper transport time between sensors
SIMULATION NO.27-10
TEST
TROUBLE PRECOGNITION HISTORY CLEAR
ARE YOU SURE?
27-11
Purpose
Function (Purpose) Used to display the serial communication
Section
Item
Operation/Procedure
1)
When the machine enters Simulation 27-11, the following
0
screen is displayed.
* Select the display page of process data with [↓] and [↑] but-
tons.
* When there is an item over [↑], the display becomes active
and shifts to the previous page.
When there is no item over [↑], the display grays out and the
operation is disabled.
When there is an item under [↓], the display becomes active
OK
and shifts the following page.
When there is no item under [↓], the display grays out and
the operation is disabled.
* When [CLOSE] button is pressed, the display shifts to the copy
basic screen of the simulation.
* Press [COLOR]/[BLACK] key to execute copying.
Data clear
information.
Communication (RIC/MODEM)
Specifications
Target history
YES
NO
EXECUTE
Adjustment/Setup/Operation data output/
Check (Display/Print)
retry number and the scanner gain adjust-
ment retry number history.
Communication (RIC/MODEM)
Specification
0
CLOSE