  • Page 1 Operating and Installation Instructions Ventilation System DAR 1120, 1130, 1150 DAR 1220, 1230, 1250 en - US, CA To prevent accidents and appliance damage, read these instructions before installation or use. M.-Nr. 09 824 260...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS....... . . 3 Description of functions ..........7 Guide to the Ventilation System .
  • Page 3: Important Safety Instructions

    Use this appliance only in the manner intended by the manufacturer. Read these instructions carefully If you have questions, contact Miele. before installing or using the b) Before servicing or cleaning the Ventilation System. appliance, switch power off at the...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS d) Before connecting the appliance to the power supply make sure that the ,WARNING voltage and frequency listed on the data plate correspond with the TO REDUCE THE RISK OF A household electrical supply. COOKTOP GREASE FIRE: This data must correspond to prevent appliance damage.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS ,WARNING This appliance is not intended for use by persons (including children) TO REDUCE THE RISK OF with reduced physical, sensory or INJURY TO PERSONS IN THE mental capabilities, or lack of EVENT OF A COOKTOP experience and knowledge, unless they GREASE FIRE, OBSERVE THE have been given supervision or FOLLOWING...
  • Page 6 This hood should only be used in d) Ducted hoods must always be combination with the DRIB XL/XXL or vented to the outdoors. DREB XL/XXL Miele Blower. e) Do not use this hood with any ,WARNING solid-state speed control device.
  • Page 7: Description Of Functions

    Description of functions The ventilation system offers the Air extraction with external blower following modes of operation: Air extraction with internal blower The external blower must be installed outside the room at a location of your choosing. A blower that is integrated into the The external blower is connected to the ventilation system removes any cooking ventilation system by a control cable...
  • Page 8: Guide To The Ventilation System

    Guide to the Ventilation System...
  • Page 9: Guide To The Ventilation System

    Guide to the Ventilation System a Duct cover in four different heights (DRDC) b Vents for recirculated air (with the DRUU recirculation kit for air recirculation mode) c Ventilation hood d OdorFree charcoal filter (behind baffle filtration) Optional accessory for air recirculation e Baffle filtration f Overhead LED light...
  • Page 10 DAR 1120 – – 30" (DRIB XXL=1100 cfm)* (DREB XXL=1100 cfm)* Blower Blower Range Insert DRIB XL=700 cfm DREB XL=700 cfm DAR 1130 – – 36" DRIB XXL=1100 cfm DREB XXL=1100 cfm Range Insert Blower Blower DAR 1150 – –...
  • Page 11: Operation

    Operation Turning the light on/off Always turn the ventilation system The overhead LED light and the blower on when cooking. can be turned on and off separately. When using a gas range regardless of the cooktop setting, use the Turning the blower on/off following power levels: ^ Turn the blower switch to "1"...
  • Page 12: Cleaning And Care

    Cleaning and Care ,WARNING Avoid: TO REDUCE THE RISK OF – cleaning agents containing soda, FIRE, ELECTRIC SHOCK, OR acids or chlorides, INJURY TO PERSONS, – abrasive cleaning agents OBSERVE THE FOLLOWING: e.g. powder or cream cleansers, – abrasive sponges, e.g. pot scourers Before cleaning or servicing the or sponges which have been hood, disconnect it from the power...
  • Page 13: Baffle Filtration

    Cleaning and Care Baffle filtration Stainless steel colored controls The stainless steel baffle filtration in the These controls may become dis- hood remove solid particles from the colored or damaged if not cleaned vented kitchen air (grease, dust, etc) regularly. and prevent soiling of the ventilation Do not use a stainless steel cleaner system.
  • Page 14 Use a wash program with a max. models can be cleaned in the temperature of 150°F (65°C). In a dishwasher. Miele dishwasher use either the "Normal" or "Grates and Filters" program. Use the recommended amount of dishwasher detergent. Overuse could destroy the filter.
  • Page 15: Odorfree Charcoal Filters

    Install the filters according to the instructions included with the kit. Replacement OdorFree charcoal filters can be ordered from Miele. Replacing the OdorFree charcoal filters ^ Insert the OdorFree charcoal filter. ^ To install or replace the OdorFree ^ Repeat these steps for each filter.
  • Page 16: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 17: Installation Instructions

    Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
  • Page 18: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 19: Appliance Dimensions

    Appliance dimensions...
  • Page 20 Appliance dimensions...
  • Page 21 Appliance dimensions a The hood with exhaust collar is only used in air extraction mode with an internal or external blower.
  • Page 22 Appliance dimensions a The hood with exhaust collar is only used in air extraction mode with an internal or external blower.
  • Page 23 Appliance dimensions...
  • Page 24 Unless the instructions require a greater distance, the adjacent minimum safety distances apply for Miele cooktops. – If several gas surfaces are installed under the hood, the total output must be considered when determining the minimum safety distance.
  • Page 25 Appliance dimensions Distance between cooktop and hood (S) Miele Range hood DAR 1120, DAR 1150, DAR 1130, DAR 1230 DAR 1220 DAR 1250 (36") (30") (48") Internal / External blowers DRIB/DREB DRIB/DREB DRIB/DREB DRIB/DREB (700 cfm) (700 cfm) (1100 cfm)
  • Page 26: Plywood Backing

    Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the retaining plate. It ^ Mark a vertical cutting line along the must be firmly attached to the stud framing behind the drywall.
  • Page 27: Installation

    Installation Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time. Installation instructions The individual installation steps are described in the included Installation...
  • Page 28: Air Extraction

    Air extraction Exhaust ducting and connections WARNING Use smooth or flexible pipework made from approved non-flammable Danger of toxic fumes. materials for exhaust ducting. To achieve the most efficient air Gas cooking appliances release extraction and quietest noise levels, carbon monoxide that can be consider the following: harmful or fatal if inhaled.
  • Page 29 Air extraction – If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent...
  • Page 30: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. ,WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 31: Technical Data

    DAR 1120, DAR 1220 ..2 x 2 W DAR 1230 DAR 1130, DAR 1230 ..3 x 2 W with DRIB XXL ..97.5 lbs (44.3 kg) DAR 1150, DAR 1250 .