hit counter script
Table of Contents

Advertisement

Quick Links

HP A-F5000 Firewall
Installation Guide
Part number: 5998-1413
Document version: 6PW100-20110909

Advertisement

Table of Contents
loading

Summary of Contents for HP A-F5000

  • Page 1 HP A-F5000 Firewall Installation Guide Part number: 5998-1413 Document version: 6PW100-20110909...
  • Page 2 MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 3: Table Of Contents

    Contents Product overview·························································································································································· 1 A-F5000 physical architecture·········································································································································1 Main processing unit (NSQ1MPUA0) ····························································································································2 Interface modules ······························································································································································2 NSQ1GT8C40·························································································································································2 NSQ1GT8P40··························································································································································3 NSQ1XP20 ·······························································································································································3 Power supplies···································································································································································3 AC-input power supply ············································································································································4 DC-input power supply ············································································································································4 Fan trays·············································································································································································5 Preparing for installation ············································································································································· 6 Safety recommendations ··················································································································································6 Safety symbols ··························································································································································6 General safety recommendations ···························································································································6...
  • Page 4 Connecting Ethernet cables··········································································································································· 26 Connecting a copper Ethernet cable··················································································································· 26 Connecting an optical fiber ································································································································· 27 Logging in to the firewall and configuring basic settings ·······················································································30 Logging in to the firewall through the console port···································································································· 30 Connecting the firewall to a configuration terminal ·························································································· 30 Setting terminal parameters··································································································································...
  • Page 5 RUN LED fast flashes············································································································································· 58 Power supply failures····················································································································································· 58 Power LED is off····················································································································································· 58 Red power LED is on ············································································································································· 59 Fan failures ····································································································································································· 59 Fan tray is absent ·················································································································································· 59 ALM LED is red ······················································································································································ 59 Configuration system problems ···································································································································· 60 No terminal display ··············································································································································...
  • Page 6 Index ···········································································································································································90...
  • Page 7: Product Overview

    Product overview This chapter includes these sections: A-F5000 physical architecture • Main processing unit (NSQ1MPUA0) • Interface modules • • Power supplies Fan trays • A-F5000 physical architecture Figure 1 Front view (1) MPU slot (slot 0) (2) Fan tray...
  • Page 8: Main Processing Unit (Nsq1Mpua0)

    Figure 2 Rear view (1) Rear cover handle (do not use this handle to lift the chassis) (2) Air filter (optional) (3) Chassis handle (4) Grounding terminal and sign (5) Air vents Main processing unit (NSQ1MPUA0) Figure 3 NSQ1MPUA0 front panel (1) CF card button (2) CF card slot (3) Captive screw...
  • Page 9: Nsq1Gt8P40

    The NSQ1XP20 provides two XFP ports and supports the LAN PHY mode only. Figure 6 NSQ1XP20 front panel Power supplies The HP A-F5000 can be DC-powered or AC-powered. You can install two power supplies in your firewall, and they must be the same model.
  • Page 10: Ac-Input Power Supply

    The A-F5000 firewall uses hot swappable power supplies. You can install one power supply, or for redundancy, two power supplies for your firewall. AC-input power supply Figure 7 AC-input power supply front view (1) AC-input power receptacle (2) Power switch...
  • Page 11: Fan Trays

    Fan trays Figure 9 Fan tray (1) Handle (2) Fans...
  • Page 12: Preparing For Installation

    Preparing for installation This chapter includes these sections: Safety recommendations • Examining the installation site • Installation tools • • Accessories supplied by the firewall Checklist before installation • Safety recommendations Safety symbols When reading this document, note the following symbols: WARNING means an alert that calls attention to important information that if not understood or followed can result in personal injury.
  • Page 13: Safety With Firewall Moving

    Any attempt to carry the firewall with these parts may cause equipment damage or even bodily injury. Examining the installation site The A-F5000 firewall can only be used indoors. To ensure that the firewall works properly and to prolong its service lifetime, the installation site must meet the following requirements: Temperature and humidity •...
  • Page 14: Altitude

    The equipment room must also meet strict limits on salts, acids, and sulfides to eliminate corrosion and premature aging of components, as shown in Table Table 5 Harmful gas limits in an equipment room Max. (mg/m 0.006 0.05 0.01 Cooling system The A-F5000 firewall adopts left to right airflow for heat dissipation.
  • Page 15: Esd Prevention

    Figure 10 A-F5000 airflow • Make sure there is enough space (greater than 10 cm (3.94 in)) around the air intake and outlet vents on the firewall for good ventilation. Make sure the installation site has a good cooling system.
  • Page 16: Emi

    Figure 11 Use an ESD-preventive wrist strap (1) ESD-preventive wrist strap (2) Lock (3) leash CAUTION: Check the resistance of the ESD-preventive wrist strap for safety. The resistance reading should be in the range of 1 to 10 megohm (Mohm) between human body and the ground. All electromagnetic interference (EMI) sources, from outside or inside of the firewall and application system, adversely affect the firewall in a conduction pattern of capacitance coupling, inductance coupling, electromagnetic wave radiation, or common impedance (including grounding system)
  • Page 17: Rack-Mounting

    Make sure the grounding terminal of the AC power receptacle is well grounded. • • Install a lightning arrester at the input end of the power supply to enhance the lightning protection capability of the power supply. Rack-mounting Before mounting the firewall in a rack, adhere to the following requirements: •...
  • Page 18: Checklist Before Installation

    Checklist before installation Table 6 Checklist before installation Item Requirements Result • There is a minimum clearance of 10 cm (3.94 in) around the inlet and exhaust vents for heat dissipation of the firewall chassis. Ventilation • A ventilation system is available at the installation site.
  • Page 19 Item Requirements Result • The firewall is far away from any moist area and heat source. Safety precautions • The emergency power switch in the equipment room is located. • Installation accessories supplied with the firewall Tools • User supplied tools •...
  • Page 20: Installing The Firewall

    Installing the firewall This chapter includes these sections: Installation flow • Check before installation • Installing the firewall in a 19-inch rack • • Grounding the firewall Installing an MPU • Installing an interface module • Installing a fan tray •...
  • Page 21: Installation Flow

    To mount multiple devices in the rack, mount the heavier equipment at a lower position. Installing the firewall in a 19-inch rack To install an A-F5000 to a rack, you need mounting brackets and rack shelves. Installing cage nuts to the rack...
  • Page 22: Installing The Cable Management Brackets

    Determine where to install the firewall in the rack, and then install a rack shelf to the rack. As shown in Figure 13, mark the positions of cage nuts on the front rack posts by using a front mounting bracket. Figure 13 Mark the positions of the cage nuts As shown in Figure...
  • Page 23: Installing The Mounting Brackets To The Firewall

    Figure 15 Install the cable management bracket (1) Left mounting bracket (2) Cable management bracket Installing the mounting brackets to the firewall NOTE: If you have ordered an air filter, install the air filter before installing the mounting brackets. For how to install an air filter, see “Installing an air filter (optional).”...
  • Page 24: Installing The Firewall To The Rack

    Installing the firewall to the rack Follow these steps to install the firewall to the rack: Put the firewall on the rack shelf, slide the firewall, and align the screw holes on the mounting brackets with the cage nuts on the rack. Fix the firewall horizontally by fastening the mounting brackets to the rack with appropriate pan head screws.
  • Page 25: Installing An Mpu

    Installing an MPU NOTE: The A-F5000 supports only one MPU, which must be installed in slot 0. • Typically the firewall does not provide a filler panel for slot 0 when it is shipped because you must install •...
  • Page 26: Installing An Interface Module

    Figure 19 Insert the MPU into slot Fasten the captive screws on the MPU with a Phillips screwdriver. After the firewall is powered on, the RUN LED flashes fast (at 8 Hz). It flashes slowly (at 1 Hz) after the application is loaded. This means that the MPU runs properly. For the LED description, see the chapter “Appendix B LEDs.”...
  • Page 27: Installing A Fan Tray

    Install the removed filler panels to prevent dust from entering the chassis. If slots 1 through 4 of the A-F5000 are all installed with interface modules, the interface modules are •...
  • Page 28: Installing A Cf Card

    Figure 21 Push the fan tray into the slot Use a Phillips screwdriver to fasten the captive screws on the fan tray. After the firewall is powered on, the RUN LED of the fan tray is steady on. This means that the fan tray runs properly.
  • Page 29: Installing An Air Filter (Optional)

    You must install the air filter before you install the mounting brackets. The air filter of the A-F5000 is installed at the air intake vents on the left of the chassis (when you face the front panel of the chassis) to prevent dust from entering the chassis.
  • Page 30: Installing A Power Supply

    Figure 25 Fasten the captive screws Installing a power supply CAUTION: The A-F5000 supports both AC and DC power supplies. You must install either AC or DC power • supplies to the firewall. The A-F5000 needs only one power supply for the whole system to operate properly.
  • Page 31: Connecting A Power Cord

    NOTE: Typically the firewall does not provide a filler panel for one of the power supply slots. You can install a power supply in that slot. The procedures for installing an AC power supply and DC power supply are the same. The following uses an AC power supply as an example.
  • Page 32: Connecting A Dc Power Cord

    Figure 27 Connect an AC power cord to the firewall Connecting a DC power cord Follow these steps to connect a DC power cord: Switch off the DC power supply. Remove the protection cover from the DC power supply. Remove the screws from the terminals on the DC power supply with a Phillips screwdriver. Connect the end marked with “–...
  • Page 33: Connecting An Optical Fiber

    After the firewall is powered on, check the status LED of the Ethernet ports. If the LED is solid green, the connection is normal. For more information about the LED status, see the chapter “Appendix B LEDs.” NOTE: For more information about Ethernet twisted pair cables, see the chapter “Appendix C Cables.”...
  • Page 34 Figure 30 Install the transceiver module Remove the dust cap from the transceiver module and the protective caps from the fibers. Plug the LC connectors on one end of the fiber cable into the Rx and Tx ports, and plug the LC connectors on the other end to the Tx and Rx ports on the peer device, as shown in Figure Figure 31 Connect the fiber connectors...
  • Page 35 Never bend or curve a fiber when connecting it. The bend radius must be not less than 10 cm (3.94 • in). Figure 32 Bend radius of the fiber Ensure the cleanness of the fiber ends. • WARNING! To avoid injury to your eyes, do not stare at the optical interfaces and optical fiber connectors when connecting optical fibers.
  • Page 36: Logging In To The Firewall And Configuring Basic Settings

    Logging in to the firewall and configuring basic settings This chapter includes these sections: • Logging in to the firewall through the console port Powering on the firewall • Logging in to the firewall through Telnet • Logging to the firewall through a web browser •...
  • Page 37: Setting Terminal Parameters

    CAUTION: When you connect the console cable, HP recommends connecting the DB-9 connector of the console • cable to the serial port, and then the RJ-45 connector to the console port of the firewall. When you remove the console cable, HP recommends removing the RJ-45 connector, and then the DB-9 •...
  • Page 38 Figure 35 Set the serial port used by the HyperTerminal connection Click OK after selecting a serial port and the following dialog box appears. Set Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, and Flow control to None.
  • Page 39 Figure 36 Set the serial port parameters NOTE: To use the default settings, click Restore Defaults. Click OK after setting the serial port parameters and the system enters the following interface. Figure 37 HyperTerminal window...
  • Page 40: Powering On The Firewall

    Logging in to the firewall through Telnet NOTE: For more information about the Telnet login, see the configuration guides for the firewall. You can use the default information to log in to the A-F5000 firewall. The default login information includes: Username: admin •...
  • Page 41: Logging To The Firewall Through A Web Browser

    Follow these steps to log in to the firewall through Telnet: Log in to the A-F5000 through the console port and then use the telnet server enable command in system view to enable the Telnet function of the firewall. By default, Telnet is disabled on the firewall.
  • Page 42: Performing Basic Settings For The Firewall

    Performing basic settings for the firewall This section describes the fast configuration by using the basic configuration wizard. For more information about how to configure the protocols and features for the A-F5000 firewall, see the configuration guides for the firewall.
  • Page 43: Configuring Service Management

    Figure 40 Basic configuration wizard: 2/6 (basic information) Table 7 Basic information configuration items Item Description Sysname Set the system name. By default, the system name of the firewall is HP. Modify Current User Specify whether to modify the login password of the current user. Password To modify the password of the current user, set the new password and the confirm password, and the two passwords must be identical.
  • Page 44 Figure 41 Basic configuration wizard: 3/6 (service management) Table 8 Service management configuration items Item Description Specify whether to enable FTP on the device. Disabled by default. Specify whether to enable telnet on the device. Telnet Disabled by default. Specify whether to enable HTTP on the device, and set the HTTP port number. Enabled by default.
  • Page 45: Configuring The Ip Address For An Interface

    Item Description Specify whether to enable HTTPS on the device, and set the HTTPS port number. HTTPS is the HTTP protocol that supports the Secure Sockets Layer (SSL) protocol. It can improve device security. For more information about HTTPS. Disabled by default. IMPORTANT: •...
  • Page 46: Configuring Nat

    Table 9 Interface IP address configuration items Item Description Set the approach for obtaining the IP address, including: • None: The IP address of the interface is not specified, that is, the interface has no IP address. • Static Address: Specify the IP address for the interface IMPORTANT: manually;...
  • Page 47: Completing The Configuration Wizard

    Table 10 NAT configuration items Item Description Select an interface on which the NAT configuration will be applied. Generally, it is Interface the outgoing interface of the device. Specify whether to enable dynamic NAT on the interface. If dynamic NAT is enabled, the IP address of the interface will be used as the IP Dynamic NAT address of a matched packet after the translation.
  • Page 48 Figure 44 Basic configuration wizard: 6/6 This page lists all configurations you have made in the basic configuration wizard. Confirm the configurations. To modify your configuration, click Prev to go back to the previous page; if no modification is needed, click Finish to execute all configurations.
  • Page 49: Hardware Management And Maintenance

    HP Comware Platform Software Comware Software, Version 5.20, Release 3206P18 Copyright (c) 2010-2011 Hewlett-Packard Development Company, L.P. HP A-F5000 uptime is 0 week, 0 day, 0 hour, 3 minutes 2048M bytes DDR2 SDRAM Memory 4M bytes Flash Memory 247M bytes CF0 Card MPUA PCB Version:Ver.B...
  • Page 50: Displaying The Operational Statistics Of The Firewall

    [SUBCARD 1] NSQ1GT8C40 (Hardware)Ver.B, (Driver)1.0, (Cpld)1.0 [SUBSLOT 2] The SubCard is not present [SUBSLOT 3] The SubCard is not present [SUBSLOT 4] The SubCard is not present Displaying the operational statistics of the firewall When you perform routine maintenance or the system fails, you may need to view the operational information of each functional module for locating failures.
  • Page 51: Displaying The Electrical Label Information Of A Module

    MPUA LX30T FPGA: 5.05 Driver : 1.0 SubCard Num : 5 CFCard Num Usb Num The SubCard1 on Board0: Status : Normal Type : NSQ1GT8C40 LPUA PCB 12GEA PCB LPUA Basic CPLD: LPUA Extend CPLD: 12GEA CPLD: LPUA LX30T FPGA: 5.05 LPUA LX110 FPGA:...
  • Page 52: Displaying The Cpu Usage Of A Module

    Displaying the CPU usage of a module Use the display cpu-usage command to display the CPU usage of the module in each slot. <Sysname> display cpu-usage Unit CPU usage: 3% in last 5 seconds 3% in last 1 minute 3% in last 5 minutes Table 11 Output description Field Description...
  • Page 53: Displaying The Operational Status Of The Fan

    Field Description Size: Storage capacity of the CF card Displaying the operational status of the fan Use the display fan command to display the operational status of the fan. <Sysname> display fan 1 State: Normal Table 13 Output description Field Description Number of the fan The fan state:...
  • Page 54: Viewing The System Fault Solving Method

    be lost after the firewall reboots. In this case, you can maintain the current status of the firewall, facilitating fault location. Follow these steps to solve system faults: To do… Use the command… Remarks Enter system view system-view — Optional Specify the system fault solving system-failure { maintain | method for the MPU...
  • Page 55: Rebooting A Module Or The Firewall

    NOTE: The configuration file must be with extension .cfg. • During the execution of the save command, the startup configuration file to be used at the next system • startup may be lost if the firewall reboots or the power supply fails. In this case, the firewall will boot with the factory defaults, and after the firewall reboots, you need to re-specify a startup configuration file for the next system startup.
  • Page 56: Replacement Procedures

    Replacement procedures This chapter includes these sections: Safety recommendations • Replacing a power supply • Replacing an MPU • • Replacing an interface module Replacing a transceiver module • Replacing a CF card • Replacing a fan tray • Replacing an air filter •...
  • Page 57: Replacing An Mpu

    Figure 45 Pull out the power supply Install a new power supply. For how to install a power supply, see the chapter “Installing the firewall.” Replacing an MPU CAUTION: The MPU does not support hot swapping. Before replacing an MPU, you must switch off the power supply of the firewall.
  • Page 58: Replacing An Interface Module

    Replacing an interface module CAUTION: The interface module does not support hot swapping. Before replacing an interface module, you must switch off the power supply of the firewall. Follow these steps to replace an interface module: Switch off the power supply. Determine the interface module to be removed.
  • Page 59: Replacing A Cf Card

    Insert the dust cap to the removed transceiver module, and put the transceiver module into its original shipping materials. If you do not install a new transceiver module in the interface, install a dust-proof plug in the interface. For how to install a transceiver module, see the chapter “Installing the firewall.”...
  • Page 60: Replacing A Fan Tray

    Figure 49 Press the eject button Press the eject button again to eject the CF card part-way out of the CF card slot, and then pull the CF card out of the CF card slot. Figure 50 Press the eject button to eject the CF card Install a new CF card.
  • Page 61: Replacing An Air Filter

    Figure 51 Pull out the fan tray Install a new fan tray. For more information, see the chapter “Installing the firewall.” NOTE: Do not keep the firewall working without a fan tray for over two minutes because poor ventilation may •...
  • Page 62 Figure 52 Loosen the captive screws of the air filter Gently pull the air filter out along the slide rails. Figure 53 Pull the air filter out along the slide rails Install a new air filter. For more information, see the chapter “Installing the firewall.”...
  • Page 63: Troubleshooting

    Troubleshooting This chapter includes these sections: MPU failures • Interface module failures • Power supply failures • • Fan failures Configuration system problems • Using the AUX port as the backup console port • Password loss • Cooling system failure •...
  • Page 64: Alm Led Is Steady On Or Flashes

    ALM LED is steady on or flashes If the ALM LED of the MPU is steady on or flashes, it indicates that the firewall is faulty. For example, the ALM LED is on when the system is over-temperature. In this case, the system displays the following output: %Jun 25 14:38:45:444 2010 HP DRVMSG/3/TempCritical: CPU temperature critical in Slot 3, index is 1.
  • Page 65: Red Power Led Is On

    Follow these steps to troubleshoot the power supply failure: Check whether the power switch is turned on. Check whether the power cables of the firewall are firmly connected. Check whether the switch of the power source is turned on. Check whether the power cable is damaged. If the cause cannot be located in the steps above and the problem persists, contact your local sales agent.
  • Page 66: Configuration System Problems

    To solve the problem, check whether any foreign object has entered the fan tray. If the cause cannot be located in the steps above and the problem persists, contact your local sales agent. Configuration system problems If the configuration environment setup is correct, the configuration terminal displays boot information when the firewall is powered on.
  • Page 67: Password Loss

    To do… Use the command… Remarks Enter AUX user interface view user-interface aux 0 — Specify the none authentication mode authentication-mode none Required Configure the user privilege level user privilege level 3 Required NOTE: To use the default authentication mode (password authentication) for AUX port login, you must configure •...
  • Page 68: Super Password Loss

    Save the new password. [Sysname] save NOTE: To save the new password, execute the save command after modifying the user password. • HP recommends saving the modification as the default configuration file. • Super password loss In the case of super password loss, you cannot perform higher level operations. You can clear the super password by selecting 8 on the main BootWare menu.
  • Page 69: Host Software File Missing Errors

    The output shows that the temperature inside the firewall has exceeded the upper threshold 75°C (167°F). In this case, the fans of the firewall will rotate at full speed. Generally, after the fans rotate at full speed for a certain period, the temperature inside the firewall will drop below 75°C (167°F), and the following information appears on the configuration terminal: %May 14 22:25:17:804 2010 HP DRVMSG/3/TempHOK: Environment temperature recovered from OT in Slot 0, index is 2.
  • Page 70 To solve this problem, download the host software file again or set the file properties in the BootWare file list.
  • Page 71: Appendix A Technical Specifications

    Appendix A Technical specifications Dimensions and weight Table 15 Dimensions and weight Item Specification Dimensions (H × W × D) (without mounting brackets) 308 × 436 × 476 mm (12.13 × 17.17 × 18.74 in) Weight (full configuration) 50 kg (110.23 lb) Power consumption range Table 16 Power consumption range of the entire system Item...
  • Page 72: Fan Tray

    Fan tray Table 19 Fan tray specifications Item Specification Rated voltage 12 VDC Total fan power consumption 50 W Dimensions (H × W × D) 227 × 31 × 413.3 mm (8.94 × 1.22 × 16.27 in) MPU (NSQ1MPUA0) Technical specifications Table 20 NSQ1MPUA0 specifications Item Specification...
  • Page 73: Components

    Components CF card A compact flash (CF) card stores logs, system software image files, and configuration files. The firewall is equipped with a built-in 256 MB CF card, which is identified with cfa0. In addition, the firewall provides an external CF card slot to expand the storage space. The CF cards supported by the firewall are available in the following sizes: 256 MB •...
  • Page 74 The management Ethernet port is used only for managing the firewall and it has no service processing capabilities such as data forwarding. High Availability includes features such as stateful failover and VRRP. The HA port on the A-F5000 is a 10Base-T/100Base-TX/1000Base-T auto-sensing RJ-45 port, used to synchronize status packets in dual-device backup networking.
  • Page 75: Interface Modules

    Interface modules NSQ1GT8C40 Table 24 NSQ1GT8C40 specifications Item Specification 10 Mbps, half/full duplex Copper ports 100 Mbps, half/full duplex 1000 Mbps, full duplex 10 Mbps, half/full-duplex Copper ports (automatic Combo interfaces 100 Mbps, half/full-duplex MDI/MDIX) 1000 Mbps, full-duplex Fiber ports 1000 Mbps, full-duplex NSQ1XP20 Table 25 NSQ1XP20 specifications...
  • Page 76: Appendix B Leds

    Appendix B LEDs MPU LEDs Figure 54 LEDs on the MPU Table 27 Firewall running status LED description Status Description Management No link is present. port/HA port link A link is present. (green) status LED Management No data is being received or transmitted. port/HA port data transmission Data is being received or transmitted.
  • Page 77: Interface Module Leds

    Status Description The MPU is in standby state or is not powered on. The MPU is in active state. MPU status LED NOTE: (yellow) The firewall supports one MPU, so the MPU can only be in active state. The system is operating properly and there is no alarm. A fault has occurred to the system or the available power is insufficient.
  • Page 78: Nsq1Xp20

    Status Description No power input is available or the interface module has failed. Slow flashing (1 The interface module is working properly. Application software is being loaded (in this case, Run LED Fast flashing (8 never power off the interface module or hot-swap (green) the interface module;...
  • Page 79: Power Supply Leds

    Power supply LEDs Figure 57 AC power supply LED Figure 58 DC power supply LED Table 30 AC/DC power LED description Status Description Solid green The power supply is working properly. Power LED Solid red The power supply is faulty. No power is input.
  • Page 80: Fan Tray Leds

    Fan tray LEDs Figure 59 Fan tray LEDs Table 31 Fan tray LED description Status Description The system is powered off or the fan tray is faulty. Run LED (green) The fan tray is working properly. The fan tray is working properly. Alarm LED (red) The fan tray is faulty.
  • Page 81: Appendix C Cables

    Appendix C Cables The HP A-F5000 firewall supports various types of interface modules. The port types vary by the interface module. Use dedicated cables to connect the ports of different types. Table 32 Cables Cable Applicable port type Description Connects the RJ-45 Ethernet port of...
  • Page 82 Figure 60 RJ-45 connector pinout NOTE: The RJ-45 Ethernet ports of the HP A-F5000 firewall use category 5 or higher Ethernet twisted pair cables for connection. EIA/TIA cabling specifications define two standards, 568A and 568B, for cable pinouts. Standard 568A—pin 1: white/green stripe, pin 2: green solid, pin 3: white/orange stripe, pin 4: •...
  • Page 83 Figure 62 Crossover cable white/orange orange white/green blue white/blue green white/brown brown Crossover cable white/green green white/orange blue white/blue orange white/brown brown Select an Ethernet twisted pair cable according to the RJ-45 Ethernet port type on your device. An RJ-45 Ethernet port can be MDI or MDIX.
  • Page 84: Making An Ethernet Twisted Pair Cable

    Table 35 RJ-45 MDIX port pinouts 10Base-T/100Base-TX 1000Base-T Signal Function Signal Function Bi-directional data Receives data BIDB+ cable B+ Bi-directional data Receives data BIDB- cable B- Bi-directional data Sends data BIDA+ cable A+ Bi-directional data Reserved BIDD+ cable D+ Bi-directional data Reserved BIDD- cable D-...
  • Page 85: Optical Fiber

    Use a cable tester to verify the proper connectivity of the cable. Optical fiber Optical fibers feature low loss and long transmission distance. Optical fibers can be classified into single mode fibers and multi-mode fibers. A single mode fiber carries only a single ray of light; a multi-mode fiber carries multiple modes of lights. Table 36 Characteristics of single mode and multi-mode optical fibers Characteristics Single mode fiber...
  • Page 86 NOTE: HP A-F5000 firewall provides shielded covers for the fiber ports (such as SFP ports). Before using such • fiber ports, remove the shielded covers. Keep the shielded covers properly. When the fiber ports are not in use, install the shielded covers.
  • Page 87: Appendix D Ac Power Cables Used In Different Countries Or Regions

    Appendix D AC power cables used in different countries or regions 10A AC power cables used in different countries or regions Table 38 10A AC power cables used in different countries or regions Countries or regions where the type of power Other countries or Countries or regions Connect...
  • Page 88 Holland, Denmark, Sweden, Finland, 04041056 (3 Indonesia, Turkey, F type Norway, Germany, India m, i.e., 9.8 ft) Russia, and CIS France, Austria, Belgium, and Italy Connector outline Power cable outline Connector outline Countries or regions where the type of power Other countries or Countries or regions Connect...
  • Page 89 Connector outline Power cable outline Connector outline Countries or regions where the type of power Other countries or Countries or regions Connect cables conforms to local regions using this type seldom using this type Code (Length) or type safety regulations and of power cables of power cables can be used legally...
  • Page 90: Ac Power Cables Used In Different Countries Or Regions

    16A AC power cables used in different countries or regions Table 39 16A AC power cables used in different countries or regions Countries or regions where the type of Countries or Other countries or Connector power cables regions seldom Code (Length) regions using this type of type conforms to local...
  • Page 91 Holland, Denmark, Sweden, Finland, 0404A061 (3 Indonesia, Turkey, F type Norway, Germany, m, i.e., 9.8 ft) Russia, and CIS France, Austria, Belgium, and Italy Connector outline Power cable outline Connector outline Countries or regions where the type of Countries or Other countries or Connector power cables...
  • Page 92 0404A01A (3 I type Australia m, i.e., 9.8 ft) Connector outline Power cable outline Connector outline...
  • Page 93: Support And Other Resources

    Support and other resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the following information: Product model names and numbers • Technical support registration number (if applicable) • Product serial numbers •...
  • Page 94: Conventions

    Conventions This section describes the conventions used in this documentation set. Command conventions Convention Description Boldface Bold text represents commands and keywords that you enter literally as shown. Italic Italic text represents arguments that you replace with actual values. Square brackets enclose syntax choices (keywords or arguments) that are optional. Braces enclose a set of required syntax choices separated by vertical bars, from which { x | y | ...
  • Page 95 Network topology icons Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features.
  • Page 96 Installing an air filter (optional),23 AC power supply,65 Installing an interface module,20 Accessories supplied by the firewall,1 1 Installing an MPU,19 A-F5000 physical architecture,1 Installing the firewall in a 19-inch rack,15 Interface module failures,58 Interface module LEDs,71 Check before installation,15...
  • Page 97 Replacing an interface module,52 Saving the current configuration of the firewall,48 Replacing an MPU,51 Solving system faults,47 Safety recommendations,50 Using the AUX port as the backup console port,60 Safety recommendations,6...

Table of Contents