Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Commissioning ............................37 Requirements for commissioning....................37 Basic commissioning - initial startup....................38 Reinstalling the software......................38 6.3.1 General installation procedure .....................38 Troubleshooting ............................39 General problems ........................39 Dimensional drawings..........................41 Dimensional drawings of the device ....................41 SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 4
Table of contents Appendix..............................45 Guidelines and declarations......................45 Certificates and approvals......................46 Service and support ........................49 Index................................ 51 SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Conventions The term "Box PC" or "device" is sometimes used to refer to the SIMATIC IPC627C product in this documentation. The abbreviation "CP" stands for CP 1616 onboard. SIMATIC IPC627C...
Battery compartment ② Device fan ③ Rating label with serial number ④ Steel cover plate for the operator panel interfaces ⑤ Status display: Two part 7 segment display and two LEDs for POST code (optional) SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 8
(please use the supplied battery mount without cover for WinAC module) ② Input data of the power supply ③ Drive bay module for hard disks and DVD burner Bottom ① Connection for equipotential bonding SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
(Off), the device is still supplied with mains voltage in order to generated the internal auxiliary voltage for the power supply. NOTICE Terminate the operating system before shutting down the device with the on/off switch, otherwise data may be lost. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 10
By default, the BIOS Setup entry "After Power Failure" is set to "Power On". This means the device is switched on with the on/off switch and you do not have to operate the on/off button. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 12
TFT displays up to 1280 x 1024 ③ USB 2.0 for front ④ Retaining screw for the steel cover plate that covers the interfaces described below. ⑤ I/O interface for connecting front panel components SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 13
2.3 Connection elements AC power supply Position of the IEC power connector Description IEC power connector to AC power supply of the device. The maximum permitted power range is 100 VAC to 240 VAC. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 14
2.3 Connection elements DC power supply Position of the DC power connector Description Plug connector for DC power supply of the device ① + (24 V DC) ② - (ground) ③ PE (ground terminal) SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
The two "virtual" CP 1616 LEDs can only be seen in the SIMATIC software and can be scanned via SNMP. PROFINET Virtual LEDs CP is active STOP CP is in the stop state Flashes There are no "slow flashing" or "fast flashing" states. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 16
7 segment display LED H1 LED H2 Power On Orange Orange (= status display test) BIOS self-test xxh (see BIOS post code) BIOS self-test completed Operating system running or controlled by application Operating system shutting down SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
● It is advisable not to dispose of the original packing material. Keep it in case you have to transport the unit. ● Keep the enclosed documentation in a safe place. It is required for initial commissioning and is part of the device. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
The Product Key is always required to reinstall the operating system. COA label Serial number: S VP ... Order No. 6ES7647-6C... Microsoft Windows Product Key Ethernet address 1 Ethernet address 2 CP 1616 onboard layer 2 SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
● The connected or built-in peripherals should not introduce negative field voltage in excess of 0.5 V into the device. WARNING Failure to adhere to these conditions when mounting the system voids the approvals based on UL 60950-1, UL 508 and EN 60950-1! SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
3.5 Permitted mounting positions Permitted mounting positions PC mounting positions according to UL60950-1/UL508/EN60950-1/CSA22.2 No. 60950-1 An inclination of ± 20° is permitted for all approved mounting positions. Position 2 Position 1 (preferred) Position 3 (desktop) SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 21
Mounting positions 4 and 5 are also permitted for the Information Technology Equipment area when the device is mounted in an enclosure that fulfills the requirements stipulated by sections 4.6 and 4.7.3 of IEC/UL/EN/DIN EN 60950-2. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
The correct use of the device has to be verified with a function test on the system. This test can detect programming, configuration and wiring errors. The test results have to be documented and if necessary inserted into the relevant inputs. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Ensure that the wall is capable of bearing four times the total weight of the device (including the brackets and expansion modules). The total weight is approx. 7 kg. Installing the device with the vertical mounting kit The optional vertical mounting kit allows space-saving installation of the device. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 25
Mounting 4.3 Installing the device with the vertical mounting kit Securing the vertical mounting plate to the device SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 26
② mounting plate Attach the vertical mounting plate with four M4 screws and three M3 screws to the device Note Please note the information in the following section Permitted mounting positions (Page 20). SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Installing the device with the vertical mounting kit for PC port access from the front The optional vertical mounting kit allows space-saving installation of the device. Securing the vertical mounting plate to the device SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 28
M4 screws: two screws on top ② and three (not shown in figure) on the bottom of the device. Note Please note the information in the following section Permitted mounting positions (Page 20). SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
The computer must be switched off and the power cable should be plugged in. During the measurement, all cables from the plant to the computer should be connected. All other components in the plant must be active. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
SIMATIC PCs with an active PFC. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 31
Use a flexible power cord which is approved to UL and CSA, and which has the following features: Type SJT with three conductors, min. 18 AWG conductor cross-section, max. length 4.5 m, and tandem grounded connector 15 A, min. 250 V. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 32
Connect the IEC connector Connecting the power cord to the power socket Fasten the cable with the supplied power plug ① latch , if necessary. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Only connect cables with a minimum cross- section of 1.3 mm (AWG16) and a maximum cross-section of 3.3 mm (AWG12). NOTICE The 24 V DC power source must be adapted to the input data of the device (see specifications). SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 34
24 V DC lines are reversed (24 V DC nominal (-15% / +20%) and connected to ground, the device will not sustain any damage. The device will simply fail to turn on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Connecting equipotential bonding Connect the equipotential bonding terminal on the device (large surface, large-area contact) to the central grounding point of the cabinet in which the device is installed. The minimum cross-section is 5 mm SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
● Connect the peripherals, such as the keyboard, mouse, monitor and the power supply, before putting the device into operation. ● The operating system you ordered for your device is already installed on the hard disk. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Contains the tools for setting up hard disk drives and the operating system. Documentation and Drivers CD: Contains the documentation and the hardware drivers. Restore DVD: Contains a hard disk image file with the original factory software (operating system with installed hardware drivers). SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
If you are using an adapter or extension for the mouse lead, check the connectors. Should the mouse cursor still not be visible on- screen after completing these checks and measures, contact technical support. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 40
Change the boot priority of the boot device in the "Boot device not found" is boot priority in the BIOS setup or is Boot menu of the BIOS setup or permit boot device displayed excluded as a boot device in the boot priority SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Dimensional drawings Dimensional drawings of the device Figure 8-1 Dimensional drawing for mounting with angle bracket SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 42
Dimensional drawings 8.1 Dimensional drawings of the device Figure 8-2 Dimensional drawing for mounting without angle bracket NOTICE When mounting devices with optical drives or WinAC backup batteries change the fitting depth. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 43
Dimensional drawings 8.1 Dimensional drawings of the device Figure 8-3 Dimensional drawings for vertical mounting (model without DVD burner and without WinAC backup battery) SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 44
8.1 Dimensional drawings of the device NOTICE When mounting devices with optical drives or WinAC backup batteries change the fitting depth. Figure 8-4 Dimensional drawing for installation with the vertical mounting kit for PC port access from the front SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
The installation guidelines and safety instructions given in this documentation have to be noted during commissioning and operation. Connecting peripherals Noise immunity requirements to EN 61000-6-2 are met if connected peripherals are suitable for industrial applications. Peripheral devices are only be connected via shielded cables. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
The currently valid approvals are to be found on the device rating plate. ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets DIN ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
Page 47
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. AUSTRALIA This product meets the requirements of the standard EN 61000-6-3:2007 Generic standards - Emission standard for residential, commercial and light-industrial environments. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 48
This product must be installed according to the NEC (National Electric Code) stipulations. When used in environments according to class I, division 2 (see above), the device must be mounted in an enclosure that corresponds to at least IP54 according to EN 60529. SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
SITRAIN homepage (http://www.sitrain.com) Online support request form: (http://www.siemens.com/automation/support-request) Industry Automation and Drive Technologies - Homepage (http://www.siemens.com/automation/service&support) Industry Mall, the ordering system for automation and drive technology (http://mall.automation.siemens.com) After sales information system from SIMATIC IPC (http://www.siemens.com/asis) SIMATIC IPC627C Getting Started, 09/2011, A5E02669077-03...
Page 50