WSK-24 Wireless Occupancy Solution

PRODUCT DESCRIPTION

The WSK-24 Wireless Occupancy Solution automatically
controls HVAC equipment by determining when a room is
occupied. The WSK-24 uses the combination of an
occupancy sensor and a door switch to provide optimal
control. The WSK-24 is packaged in a kit that includes
the following components:
• One 24V dry contact receiver
• One wireless PIR (passive infrared receiver)
occupancy sensor with mounting kit
• One wireless door sensor with mounting kit
• One wiring harness.
The receiver can be wired into any thermostat or
controller that supports the connection of a remote
setback device. The receiver communicates wirelessly to
a PIR occupancy sensor, a door sensor, and an optional
nd
2
door/window sensor. After the receiver determines
INSTALLATION INSTRUCTIONS
that the room is unoccupied it closes a dry contact
switch. After the thermostat or controller recognizes the
contact closure, it places the thermostat in economy
setback mode, which provides energy savings for when
the room is unoccupied.
FEATURES
• Wireless system provides quick and easy
installation
• Pre-configured door sensor and occupancy
sensor
• Guest comfort is maintained by never turning off
HVAC equipment when someone is in the room –
even if they are sleeping
• Fuse protection
• Long battery life
• Low battery indication
• Receiver memory retained after power loss
• Optional sliding door/window sensor can be
easily added
Product Description .................................................... 1
Features ..................................................................... 1
Ordering Information .................................................. 2
Specifications ............................................................. 2
Installation .................................................................. 3
Thermostat Configuration ................................. 3
Wiring ................................................................ 3
Setting the Delay on the Receiver .................... 4
Mounting ........................................................... 4
Battery Replacement ........................................ 6
Operation ................................................................... 6
Door (Zone 1) and PIR Occupancy Motion Sensor
(Zone 2) ............................................................ 6
Optional Sliding Door/Window Sensor (Zone 3) 6
Sensor Discovery ....................................................... 7
System Testing ........................................................... 7
Front Door Sensor & PIR Sensor ..................... 7
2nd Door Sensor ............................................... 7
Limited Two-Year Warranty ........................................ 8
Customer Assistance ................................................. 8
Contents
62-0300ES-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell WSK-24

  • Page 1: Product Description

    HVAC equipment by determining when a room is occupied. The WSK-24 uses the combination of an occupancy sensor and a door switch to provide optimal control. The WSK-24 is packaged in a kit that includes the following components: • One 24V dry contact receiver •...
  • Page 2: Ordering Information

    If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products sales office (check the white pages of your phone directory).
  • Page 3: Installation

    Therefore, the thermostat should be set so that the relay on the thermostat is normally closed. Use Table 2 or Table 1 to determine the desired Installer Codes for the thermostat being used with the WSK-24. Table 1. MultiPRO™ Installer Setup Codes. Code...
  • Page 4: Setting The Delay On The Receiver

    WSK-24 WIRELESS OCCUPANCY SOLUTION TO THERMOSTAT WIRING HARNESS RECEIVER 1. WIRE RED AND WHITE WIRES TO 24 VAC POWER AND COMMON. 2. WIRE WHITE/BROWN AND BROWN WIRES TO DRY CONTACT TERMINALS ON THERMOSTAT. ANTENNA Fig. 3. Receiver and wiring harness.
  • Page 5 2. Power the PIR sensor by inserting the three AAA 3. Secure the PIR sensor to the wall using one of the M29155 WSK-24 WIRELESS OCCUPANCY SOLUTION screws or adhesive tape provided. An optional spacer is provided, as well. See Fig. 9.
  • Page 6: Battery Replacement

    1. Remove the battery tab from the sliding door/ 2. Make sure the sliding door/window sensor and M29159 the door sensor supplied with the WSK-24 Wireless Occupancy Solution. window sensor. See Fig. 5 on page 4. magnet are close to each other, within 3/4 in. (19 mm), and that the tab notches on the sensor face the magnet.
  • Page 7: Sensor Discovery

    As soon as the sliding door or window is closed, the thermostat returns to normal operation. SENSOR DISCOVERY NOTE: The WSK-24 Wireless Occupancy Solution comes with the front door sensor and the PIR occupancy motion sensor already discovered by the receiver.
  • Page 8: Limited Two-Year Warranty

    Golden Valley, MN 55422 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
  • Page 9: Table Of Contents

    La WSK-24 usa la combinación de un sensor de ocupación y un interruptor de puerta para ofrecer el mejor control. La WSK-24 viene en un kit que incluye los siguientes componentes: • Un receptor de contacto seco de 24 V •...
  • Page 10: Información Sobre Pedidos

    SOLUCIÓN INALÁMBRICA DE DETECCIÓN DE OCUPACIÓN WSK-24 INFORMACIÓN SOBRE PEDIDOS Al comprar productos de reemplazo y modernización del mayorista o distribuidor TRADELINE®, consulte en el catálogo u hoja de precios de TRADELINE® los números de solicitud completos. También puede solicitar pedidos en http://customer.honeywell.
  • Page 11: Instalación

    Todo el cableado debe cumplir con los códigos, ordenanzas y reglamentos eléctricos nacionales y locales. La WSK-24 debe recibir alimentación de un transformador aprobado de 24 V CA, clase 2 con clasificación NEMA. Configuración del termostato Consulte las instrucciones de instalación del termostato...
  • Page 12: Configuración Del Retraso En El Receptor

    SOLUCIÓN INALÁMBRICA DE DETECCIÓN DE OCUPACIÓN WSK-24 AL TERMOSTATO MAZO DE CABLES RECEPTOR 1. TIENDA LOS CABLES ROJO Y BLANCO A LAS TERMINALES DE ALIMENTACIÓN DE 24 V CA Y COMÚN. 2. TIENDA LOS CABLES BLANCO/ CAFÉ Y CAFÉ A LAS TERMINALES DE CONTACTO SECO EN EL TERMOSTATO.
  • Page 13 DISTANCIA MÁXIMA ENTRE EL SENSOR Y EL IMÁN DE 19 MM (3/4 PULG.) Fig. 8. Distancia máxima entre el sensor de puerta y el imán. SOLUCIÓN INALÁMBRICA DE DETECCIÓN DE OCUPACIÓN WSK-24 8. Fije el imán a la puerta con los dos tornillos o la SOPORTE DE MONTAJE LENGÜETA PARA...
  • Page 14: Reemplazo De La Batería

    SOLUCIÓN INALÁMBRICA DE DETECCIÓN DE OCUPACIÓN WSK-24 a. Montaje en pared, opción 1: use la cinta adhe- siva para fijar la placa posterior del PIR a la pared. b. Montaje en pared, opción 2: inserte los dos tornillos largos en los dos orificios superiores o inferiores de la placa posterior del PIR para fijarla a la pared.
  • Page 15: Sensor Opcional Para Puerta O Ventana Corrediza (Zona 3)

    DESCUBRIMIENTO DEL SENSOR NOTE: La solución inalámbrica de detección de ocupación WSK-24 viene con el sensor de puerta delantera y el sensor de movimiento de ocupación de PIR ya detectados por el receptor. No debe haber necesidad de volver a descubrir estos dispositivos.
  • Page 16: 2º Sensor De Puerta

    1885 Douglas Dr. N Golden Valley, MN 55422 Esta garantía no cubre costos de remoción o reinstalación. Esta garantía no se aplica si Honeywell demuestra que el defecto o falla fue provocado por daño ocurrido mientras el producto estaba en poder del consumidor.