COOKTOP SAFETY ........................................................................2
INSTALLATION REQUIREMENTS ................................................2
Tools and Parts ............................................................................2
Location Requirements ................................................................3
Venting Requirements ..................................................................4
Venting Methods ..........................................................................5
Electrical Requirements ...............................................................7
INSTALLATION INSTRUCTIONS ..................................................7
Prepare Cooktop ..........................................................................7
Install Foam Strip..........................................................................8
Install Cooktop .............................................................................8
Make Electrical Connection .........................................................9
Complete Installation..................................................................10
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10439665B
DOWNDRAFT COOKTOP
INSTALLATION INSTRUCTIONS
Table of Contents/Table des matières
SÉCURITÉ DE LA TABLE DE CUISSON .................................11
EXIGENCES D'INSTALLATION................................................11
Outils et pièces........................................................................11
Exigences d'emplacement......................................................12
Exigences concernant l'évacuation ........................................14
Méthodes d'évacuation...........................................................15
Spécifications électriques .......................................................16
INSTRUCTIONS D'INSTALLATION .........................................17
Préparation de la table de cuisson .........................................17
Installation de la bande de mousse ........................................17
installations..............................................................................18
Installation de la table de cuisson...........................................18
Raccordement électrique........................................................19
Achever l'installation ...............................................................20

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid 30" (76.2 cm) Cooktop

  • Page 1: Table Of Contents

    30" (76.2 CM) AND 36" (91.4 CM) ELECTRIC DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D'INSTALLATION DE LA TABLE DE CUISSON ÉLECTRIQUE AVEC ASPIRATION PAR LE BAS DE 30" (76,2 CM) ET 36" (91,4 CM) Table of Contents/Table des matières COOKTOP SAFETY ................2 SÉCURITÉ...
  • Page 2: Cooktop Safety

    COOKTOP SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER”...
  • Page 3: Location Requirements

    Location Requirements IMPORTANT: Observe all governing codes and ordinances. 36" (91.4 cm) Cooktop - for standard and electric models When installing cooktop, use minimum dimensions given. To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage space located above the surface units should be avoided.
  • Page 4: Venting Requirements

    Cabinet Dimensions Cutout Dimensions A. 28 " (73.3 cm) maximum on 30" (76.2 cm) models " (87.8 cm) maximum on 36" (91.4 cm) models B. 21 " (53.7 cm) maximum on both 30" (76.2 cm) and 36" (91.4 cm) models C.
  • Page 5: Venting Methods

    For Best Performance: Venting Methods Use 26-gauge minimum galvanized or 25-gauge minimum aluminum metal vent. Poor quality pipe fittings can reduce Common venting methods are shown for a counter-mounted airflow. Flexible metal vent is not recommended. downdraft cooktop. The cooktop may be vented through the wall or floor.
  • Page 6 Concrete Slab Installations - Exhaust Through Wall 6" (15.2 cm) to 3 " x 10" 1 ft (8.3 cm x 25.4 cm) transition (0.3 m) 3 " x 10" (8.3 cm x 25.4 cm) 9.0 ft to 6" (15.2 cm) 90° elbow (2.7 m) transition 6"...
  • Page 7: Electrical Requirements

    Electrical Requirements Before You Make the Electrical Connection: WARNING To properly install your cooktop, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate, 40-amp circuit breaker is required for both 30"...
  • Page 8: Install Foam Strip

    4. Remove the removable grease filter by lifting the filter out. To rotate blower: 5. Using 2 or more people, remove the cooktop from the carton. 1. Locate the four plastic plugs in the plenum bypass. 6. Use foam end caps from the packaging as a work surface for 2.
  • Page 9: Make Electrical Connection

    Make Electrical Connection WARNING 4-Wire Cable from Home Power Supply to 4-Wire Cable from Cooktop IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, new branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada.
  • Page 10: Complete Installation

    3-Wire Cable from Home Power Supply to 4-Wire Cable Complete Installation from Cooktop - U.S. only 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped. IMPORTANT: Use the 3-wire cable from power supply where 2.
  • Page 11: Sécurité De La Table De Cuisson

    SÉCURITÉ DE LA TABLE DE CUISSON Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 12: Exigences D'emplacement

    Exigences d’emplacement IMPORTANT : Observer les dispositions de tous les codes et Table de cuisson de 36" (91,4 cm) - Pour les modèles règlements en vigueur. Lors de l’installation de la table de standard et électriques cuisson, utiliser les dimensions minimales indiquées. Afin de supprimer le risque de brûlures ou d'incendie en se penchant au-dessus des unités de surface chauffées, le rangement en armoire au-dessus des unités de surface doit...
  • Page 13 Dimensions du placard Dimensions de l’ouverture à découper A. 28 " (73,3 cm) maximum sur les modèles de 30" (76,2 cm) " (87,8 cm) maximum sur les modèles de 36" (91,4 cm) B. 21 " (53,7 cm) maximum sur les modèles de 30" (76,2 cm) et de 36"...
  • Page 14: Exigences Concernant L'évacuation

    Exigences concernant l'évacuation IMPORTANT : L'évacuation de cette table de cuisson doit se Ne pas installer 2 coudes ensemble. faire à l'extérieur. Ne pas utiliser plus de trois coudes à 90°. Ne pas terminer le circuit d'évacuation dans un grenier ou Si l'on utilise un coude, on doit le placer le plus loin possible dans un autre espace fermé.
  • Page 15: Méthodes D'évacuation

    Méthodes d'évacuation Les méthodes d'évacuation standard illustrées correspondent à Installations dans dalle de béton - Évacuatio à travers un une table de cuisson avec aspiration par le bas montée sur puits de fenêtre comptoir. L'évacuation de la table de cuisson peut se faire par le mur ou le plancher.
  • Page 16: Spécifications Électriques

    Exemple de circuit d'évacuation Calcul de la longueur effective du circuit d'évacuation bouche de décharge murale coude à 90˚ Pour calculer la longueur effective du circuit d’évacuation 6 pi (1,8 m) nécessaire, additionner les longueurs équivalentes (pieds/mètres) de tous les composants utilisés dans le système. Composant Conduit de diamètre de 6"...
  • Page 17: Instructions D'installation

    Avant d’établir la connexion électrique : Pour installer la table de cuisson correctement, il faut établir le Un connecteur de conduit homologué UL ou CSA doit être type de raccords électriques que l’on utilisera et suivre les fourni à chaque extrémité du câble d’alimentation électrique instructions indiquées ici.
  • Page 18: Rotation Du Ventilateur - Obligatoire Pour Certaines Installations

    3. Insérer la clé à douille de " et la rallonge dans le trou et Rotation du ventilateur - Obligatoire pour dévisser l’écrou d’un demi-tour à l’aide de la poignée à cliquet. Répéter cette opération pour chacun des quatre certaines installations écrous.
  • Page 19: Raccordement Électrique

    Raccordement électrique AVERTISSEMENT Câble à 4 conducteurs depuis le point de distribution du domicile jusqu'au câble à 4 conducteurs de la table de cuisson IMPORTANT : Utiliser le câble à 4 conducteurs provenant du point de distribution du domicile aux États-Unis lorsque les codes ne permettent pas la mise à...
  • Page 20: Achever L'installation

    Câble à 3 conducteurs depuis le point de distribution du Achever l'installation domicile jusqu'au câble à 4 conducteurs de la table de 1. Vérifier que toutes les pièces sont maintenant installées. S'il cuisson - É.-U. seulement reste une pièce, passer en revue les différentes étapes pour découvrir laquelle aurait été...