Mitsubishi dx-tl4516u digital recorders: user guide (42 pages)
Summary of Contents for Mitsubishi Electric DX-NT400E
Page 1
DIGITAL RECORDER INSTALLATION AND OPERATION MANUAL MODEL DX-NT400E THIS INSTRUCTION MANUAL IS IMPORTANT TO YOU. PLEASE READ IT BEFORE USING YOUR DIGITAL RECORDER.
NT400E has 5 user selectable recording picture grades can be registered. Furthermore, individual settings can and 12 recording time modes. The DX-NT400E also has be made for pre-alarm recording and motion detection a built-in 4 camera multiplexer with motion detection per function as well.
Caution and care HEAVY OBJECTS SHOULD NEVER BE PLACED ON THE UNIT (E.G., TV) NEVER TOUCH OR INSERT ANY OBJECT INSIDE THE UNIT Touching the inside of the cabinet or inserting foreign objects of any kind not only creates a safety hazard but can also cause extensive damage.
<RECORD SETTINGS> ........41-43 Settings concerning normal recording and alarm Attaching and removing the HDD recording ............ 41 to the DX-NT400E ......... 14-17 Recording mode settings for normal recording Attaching and removing the HDD tray ......15 and alarm recording ......41-43 Removing the HDD tray from the recorder ....
Page 5
Various recordings ..........61 Glossary ..............82 PRE ALARM RECORDINGS ........61 Glossary ..............82 EMERGENCY RECORDING ........61 Relation of recording operation to the number of cameras and recording interval settings..82 Various playback functions ........62 Specifications ............83 Playing still frames ............
See “ Connecting the wired remote control R-400 (supplied)” on page 13. Attaching the HDD • Attach the HDD to this unit. See “ Attaching and Removing the HDD to the DX-NT400E” on pages 14 to 17. Setting up the unit • Test the HDD attached to the unit.
Page 7
Setting the motion detection • Select the camera number. See “ SELECTION CAMERA NUMBER” on page 38. • Set the detection areas. See “ DETECTION MASK SETTING” on page 38. • Set the sensitivity. See “ SENSITIVITY” on page 39. •...
Major operations and their functions Front view DIGITAL RECORDER DX - NT400 LOCK POWER REMOTE ALARM ACCESS INTERRUPT WARNING LINK RX/TX 6 7 8 9 10 11 1. HDD tray 9. WARNING indicator Attach the HDD which is commercially available to Illuminates when a warning is displayed on the here.
Rear view MAIN VIDEO CAMERA IN AC IN RS-232C ETHERNET RESET AUDIO 1. MAIN switch 8. RESET button This is the main power switch. When using this unit, Pressing this button resets the unit and the power set this switch to ON. Otherwise, the power cannot turns off.
Major operations and their functions (continued) Wired remote control R-400 (supplied) 5. REC/STOP buttons When pressing both buttons, recording starts and the REC indicator on the front panel lights up. When pressing both buttons during recording, recording stops and the REC indicator turns off. During timer recording, recording does not stop even when both buttons are pressed.
12. TIMER ON/OFF buttons When pressing both buttons, the unit is set to timer recording/standby mode. When pressing both buttons again, timer recording/standby mode is can- celled. 13. PLAY button When pressing this button during stop mode, the playback speed changes in the 4 grades (normal } 25 fields/second } 30 MB units } 300 MB units} normal).
Connections Connecting to CCTV camera, monitor, and sensor MONITOR To AUDIO IN connector To VIDEO IN connector To VIDEO OUT connector To AUDIO OUT connector CAMERA #1 CAUTION Connecting a coaxial transmission camera incorrectly may damage the To CAMERA IN 1 connector input terminal.
Alarm recording connection Example: The diagram below shows an example of connection for alarm signals corresponding to camera number 1. RESET AUDIO ALARM SWITCH Connecting the wired remote control R-400 (supplied) DIGITAL RECORDER DX - NT400 LOCK POWER REMOTE ALARM ACCESS INTERRUPT WARNING LINK...
Attaching and removing the HDD to the DX-NT400E Make sure that the POWER button on the front panel and the MAIN switch on the rear panel are both turned OFF when attaching or removing the HDD tray. Do not remove the top cover of the unit.
5. Hold the HDD tray with both hands and pull it out. Attaching and removing the HDD tray Be sure to use both hands when pulling out the Removing the HDD tray from the unit HDD tray in order to prevent the trouble of the HDD 1.
Attaching and removing the HDD to the DX-NT400E (continued) 5. Connect the middle connector of the ATA LEAD to the HDD. Attaching the HDD to the HDD tray When attaching one HDD: 1. Remove the top cover from the HDD tray.
8. Attach the top cover of the HDD tray. 5. Connect the POWER LEAD to the additional HDD. • To attach the top cover, put the hooks of the top cover in • Make sure that the POWER LEAD between the HDDs is the openings of the HDD tray.
HDD SELF TEST HDD SELF TEST Before using the HDD attached to this unit, test the HDD whether to be used correctly. There are 3 types of the test method and choose one in the <HDD SELF TEST> screen. When choosing, refer to the table below which describes the details of each method.
1. Attach the HDD to the unit, and connect the cameras, the 5. Press the ENTER button to execute the test. monitors, and the wired remote control ( see pages 12 to • The test is executed and the status screen appears. •...
AUTO SET UP 6. Press the JOG buttons to move the cursor to AUTO SET UP “EXECUTE” and then press the ENTER button. AUTO SET UP is displayed, in order to set up an • “PERFORM AUTO SET UP?” is displayed on the screen. indispensable function, when this unit is turned on for the first time.
9. Press the ENTER button. Set “BOOT UP DELAY” with enough time to • The background of the setting item turns red and flashes. accomodate the recognition time of attached HDD. 10. Press the JOG buttons to display the desired setting and then press the ENTER button.
Basic operations Multiplexer functions Menu settings SPLIT/SINGLE, ZOOM, +, – and JOG buttons are used to Menu screens are used to set the operational conditions perform some of the multiplexer functions. of this unit. Although the setting method differs slightly depending on the menu screen, the basic setting method Multiplexer operation of using the JOG, ENTER, and CLEAR buttons is described...
6. Press the ENTER button. DAYLIGHT SAVING/DAYLIGHT SETTING • The setting item is determined and flashing stops. Auto daylight saving function is used to set the time period • To continue with other settings, repeat steps 4 to 6. to move the clock an hour. To activate this function, set the desired time period in “DAYLIGHT SETTING”...
Basic operations (continued) 9. Press the JOG button to move the highlighted display TIME DATE ADJUST to “MINUTE” and press the ENTER button. And then repeat Before you start recording, it is necessary to set step 8. accurately the present date and time. 10.
2. Press the JOG buttons to move the cursor to Basic manual recording “RECORD SETTINGS” and then press the ENTER button. Normal recording using manual operation is described • The <RECORD SETTINGS> screen appears. below. Before you start recording, check the settings of “HDD REPEAT REC MAIN”...
Basic operations (continued) 7. Press the JOG button to highlight the setting item of Basic playback “GRADE” and then press the ENTER button. This unit allows recorded video to be played back using • The background of the setting item turns red and flashes. various methods.
Page 27
3. Press the JOG buttons to display “03” for “DAY” and “SUB” appears when “HDD SETTING” in the then press the ENTER button. <INITIALIZATION> is set to “PARTITION.” • Setting item is determined and flashing stops. 10-2. Press the JOG buttons to display the desired 4.
Basic operations (continued) 14. Press either the PLAY button or the PAUSE button to playback the searched image. For playback, see “Various playback functions” on page 62. 15. To stop playback/still frame playback, press the STOP button. • The display returns to the normal screen. LANGUAGE SELECTION With this unit, the menu screen display can be selected from six languages.
Menu functions MENU SETTING You can set the basic settings for this unit in the menu setting. Refer to pages shown below for details. During playback, recording, and pre-alarm recording stand-by mode, you cannot change some of the menu settings. SET UP button MAIN MENU SUB MENU (1)
Page 31
SET UP button MAIN MENU <SETTINGS> >>TIME DATE/DISPLAY SETTINGS MPX DISPLAY SETTINGS MOTION DETECTION SETTINGS RECORD SETTINGS TIMER PROGRAM SETTINGS INITIAL SET UP/INFORMATION MEMO: SUB MENU (1) SUB MENU (2) <INITIAL SET UP/INFORMATION> <HDD SETTINGS> >>HDD SETTINGS >>HDD REPEAT REC MAIN AUDIO RECORDING HDD REPEAT REC SUB REAR TERMINAL SETTINGS...
Page 32
Menu functions (continued) SET UP button SUB MENU (2) SUB MENU (3) MAIN MENU SUB MENU (1) <SETTINGS> <INITIAL SET UP/INFORMATION> <INFORMATION/SERVICE> <HDD INFORMATION> >>TIME DATE/DISPLAY SETTINGS >>HDD SETTINGS >>HDD INFORMATION MPX DISPLAY SETTINGS AUDIO RECORDING WARNING LOG LIST A: HDD(120GB) MOTION DETECTION SETTINGS REAR TERMINAL SETTINGS RESET TO FACTORY SETTINGS...
SEARCH SELECTION MENU SEARCH button MAIN MENU SUB MENU (1) <TIME DATE SEARCH> <SEARCH SELECTION> SEARCH TYPE TIME DATE >>01-01-2003 00:00:00 >>SELECTION CAMERA NUMBER EXECUTE(FORWARD) PLAYBACK DEVICE MAIN SEARCH button MAIN MAIN START ---------- --:--:-- ---------- --:--:-- START ---------- --:--:-- PUSH SEARCH KEY FOR ---------- --:--:-- SEARCH SELECTION...
<TIME DATE/DISPLAY SETTINGS> TIME DATE ADJUST CLOCK LOCATION SETTING See page 24. This menu is used to set the display position of the date and present time. DISPLAY MODE 1. Press the SET UP button } <SETTINGS> } Select This item is used to set the display format of the date and “CLOCK LOCATION SETTING”...
Example: Setting titles of “ENTRANCE” and “COUNTER” to camera number “ ” and “ ,” respectively, and setting <CAMERA TITLE/MEMO SETTING> >> ENTRANCE memo of “BANK.” •••••••••••••••• •••••••••••••••• 1. Press the SET UP button } <SETTINGS> } Select COUNTER MEMO BANK “CAMERA TITLE/MEMO SETTING”...
<MPX DISPLAY SETTINGS> The multiplexer function of this unit allows the connected The magnification display function can be set only camera video to be displayed in the splited screen. It is during single screen display. The centre point moves also possible to set the order of the camera number to be vertically/horizontally by pressing the JOG buttons.
SPLIT4 SCREEN SETTING Setting of “NUMBER” (default: “ ”) This menu is used to set the camera number to be displayed “ ,” “ ,” “ ,” “ ,” “ - ” in the screen splited in 4. “ - ”: Displays nothing. 1.
<MOTION DETECTION SETTINGS> 1. In “SELECTION CAMERA NUMBER,” select the camera This menu is used to set the conditions of the motion for which the detection area is set. detection function for alarm recording which is started when detecting motion within the video of the connected camera. 2.
1. In “SELECTION CAMERA NUMBER,” select the camera SENSITIVITY for which the motion threshold is set. This item is used to set the sensitivity of detecting the changes of the loaded video data. Video data is sampled 2. Display the desired setting in “MOTION THRESHOLD” and every 0.5 second and compared with each video data of press the ENTER button.
<MOTION DETECTION SETTINGS> (continued) 1. In “SELECTION CAMERA NUMBER,” select the camera MD LOCK OUT TIME for which the MD lock out time is set. This item is used to restrict motion detection function in order to control the recording to prevent the continuous 2.
<RECORD SETTINGS> 1. Press the SET UP button } <SETTINGS> } Select Settings concerning normal recording and “ALARM SETTING” in the <RECORD SETTINGS> screen and alarm recording then press the ENTER button. This unit allows you to set the setting items for normal •...
<RECORD SETTINGS> (continued) ALARM TYPE RECORD SETTING This item is used to set the camera selection during alarm This menu is used to set the recording intervals and recording. recording picture quality for normal recording and alarm recording. <ALARM SETTING> ALARM RECORD CAMERA TRIGGER <RECORD SETTING>...
PRE ALARM REC ALARM REC DURATION This item is used to set the pre-alarm recording. This item is used to set the recording time for alarm recording. <RECORD SETTING> GRADE A-PPS A-GRADE <RECORD SETTINGS> 3.125P STD 3.125P STD ALARM SETTING 3.125P STD 3.125P STD RECORD SETTING...
<TIMER PROGRAM SETTINGS> TIMER PROGRAM SETTINGS 7) MD Sets the motion detection function to on or off. This menu is used to set up to 3 most frequently used operation patterns. By individually setting the recording 8) Displays the selected timer program number (P1 - P3). camera, recording intervals, and recording picture quality for normal recording/alarm recording to REC MODE A to 9) SPL (special day of the week setting)
Page 45
7. Press the JOG button to highlight the setting item of 18. Press the JOG button to highlight the end day and then “hour” of the start time and then press the ENTER button. press the ENTER button. • The background of the setting item turns red and flashes. •...
<TIMER PROGRAM SETTINGS> (continued) 3. To continue with REC MODE B to REC MODE D, repeat HOLIDAY SETTING steps 1 and 2. This menu is used to set holidays throughout the year. The storage area in MAIN HDD set in “PARTI- <HOLIDAY SETTING>...
<INITIAL SET UP/INFORMATION> HDD SETTINGS HDD REPEAT PLAY This item is used to playback the recorded contents of the HDD REPEAT REC MAIN/HDD REPEAT REC HDD repeatedly. This item is used to set the operation when HDD space <HDD SETTINGS> HDD REPEAT REC MAIN becomes full during recording.
<INITIAL SET UP/INFORMATION> (continued) AUDIO RECORDING When executing complex playback operations This item is used to simultaneously record audio along with with the PLAY or REV.P button during alteration the video. When recording audio, the continuous recording check, the “IMAGE MODIFIED” warning may appear. time becomes shorter than when recording only video.
3. To set other terminals, repeat step 2. REAR TERMINAL SETTINGS 4. Press the CLEAR button or the SET UP button. MODE OUT 1 to MODE OUT 5 These items are used to output the status of this unit from KEY SOUND the MODE OUT terminals on the rear panel.
<INITIAL SET UP/INFORMATION> (continued) 2. Press the JOG buttons to display the desired HDD Setting (default: “OFF”) and then press the ENTER button. “OFF,” “REMAIN,” “WARNING,” “ALARM” • The setting item is determined and flashing stops. SETTING 3. Press the JOG button to highlight the REMAIN HDD REMAIN WARNING...
INFORMATION COMMUNICATION PORT SETTINGS For the relationship between the warning display and CALL OUT signal output, see page 81. The <COMMUNICATION PORT SETTINGS> warning display of the item written “Fixed” in the >>RS-232C ETHERNET CALL OUT output column displays unconditionally. For the item written “Selectable”...
<INITIAL SET UP/INFORMATION> (continued) 4. Press the JOG buttons to display the desired number Setting of “TRANSMISSION MODE” (default: “9600”) and then press the ENTER button. “1200,” “2400,” “4800,” “9600,” “19200” • The setting item is determined and flashing stops. •...
Page 53
2. (When setting the IP ADDRESS or port setting number, etc. of the connected PC • • • ) <SERVICE PORT SETTING> Press the JOG buttons to select the desired setting >>WEB •00080 USER ACCESS 53705 number and then press the ENTER button. SUPER USER 53706 •...
<INITIAL SET UP/INFORMATION> (continued) INFORMATION/SERVICE The failures displayed in the WARNING LOG LIST: ( see page 81). This menu is used to check the log list or list of power “P-LOSS”: Power failure. failures, etc., and to initialize the menus. “SYS RST”: Reset button is pressed and the unit is At the bottom of the screen, the following information reset.
MAIN HDD DATA CLEAR/SUB HDD DATA CLEAR When the MAIN switch on the rear panel is set to This menu is used to erase the data recorded on the MAIN OFF or when a menu is displayed, SIMPLE LOCK HDD or SUB HDD. and PASSWORD LOCK do not function.
Page 56
<INITIAL SET UP/INFORMATION> (continued) To register the PASSWORD • • • 2-7. Press the CLEAR button. Register a 4-digit number for PASSWORD. When setting 3-1. (When registering the PASSWORD for HDD DATA CLEAR the number of each digit, choose the number from 0 to 9. (level 4) •...
6. Press the JOG buttons to move the cursor to 3-1. (To change the PASSWORD of level 4 • • • ) “EXECUTE” and then press the ENTER button. Display the <PASSWORD> screen. Press the JOG • The normal screen appears. buttons to move the cursor to “HDD DATA CLEAR”...
Operation examples Operation example 1 Setting different number of cameras to REC MODE A and <TIMER PROGRAM SETTINGS> >>SELECTED PATTERN P1-SET B for normal recording to switch cameras depending on HOLIDAY SETTING the time period and day of the week. REC MODE A REC MODE B REC MODE C...
Operation example 2 Setting the holiday. <TIMER PROGRAM> START END MODE >>1 SPL 08:00 15:00 A < Operation > 2 SPL 15:00 20:00 B • REC MODE A (normal recording with all the cameras) is 3 SAT 08:00 17:00 B 4 SUN 08:00 17:00 B set to Monday to Friday from 08:00 to 15:00, and REC...
Various recordings PRE ALARM RECORDINGS 2) Used cameras All the cameras of which “PPS” or “A-PPS” is set to other During alarm recording, recording starts a few seconds than “- - - - - -.” before the ALARM IN terminal is grounded or motion is detected.
Various playback functions Playing still frames Simultaneous playback during recording The recorded data can be played back simultaneously dur- 1. Press the PAUSE button during playback. ing the unit is recording. • The unit switches to still frame playback. Press the PAUSE button again or press the PLAY button to resume playback.
Various search The various search functions of this unit can be used to “ ” to “ ”: When the search type which can select skip to the desired video. the camera number is set, the unit searches the specified conditions of the selected camera and SEARCH SELECTION displays the search result in the single screen The search screen appears when the SEARCH button is...
Various search (continued) INDEX SEARCH/ALARM INDEX SEARCH Index signals are automatically written to the HDD at the start point of each recording. It is possible to search these signals and start playback from such index point. There are 2 types of index search: •...
6. To stop playback or still-frame playback, press the STOP button. During still frame playback, to choose the desired video from the SPLIT4 screen display and display the video of that camera number in the single screen display, press the SEARCH button to clear the search screen first, and then press the SPLIT/SINGLE button and the +, –...
Various search (continued) 3. Select the desired alarm list number. ALARM LIST SEARCH • button: Selects the next number. This unit stores the start times of alarm recording and emer- • button: Selects the previous number. gency recording in the alarm list when such recording is •...
START/END SEARCH It is possible to search the recording start/end point of the playback device selected in <TIME DATE SEARCH>, <IN- DEX SEARCH>, and <ALARM INDEX SEARCH>. 1. Press the SEARCH button. • The search screen selected in “SEARCH TYPE” appears. 2-1.
Other convenient functions Power failure compensation circuit When “COVERT CAMERA SETTING” is set to The unit is equipped with an internalized power failure “OFF,” the playback video of the corresponded compensation circuit. When the unit has been charged for camera number is not displayed. Furthermore, the 48 hours (full), the date, time, timer record settings, and operation mode display and alarm display do not menu settings are kept up to 1 month without power.
3. Press the JOG buttons to display “MIRRORING” and HDD SETTING then press the ENTER button. On this unit, you can select “MIRRORING” or “PARTITION” • The setting item is determined and flashing stops. for the HDD recording mode ( see page 21).
Other convenient functions (continued) PARTITION/PARTITION SIZE The area of MAIN HDD set in “PARTITION” is This item is used to set an independent partition in HDD as displayed with the percentage (%) and the record- sub-device capacity for alarm recording. In the MAIN HDD, able time of that storage area is displayed in “<ESTD normal recording and alarm recording are stored.
Communications by Web Browser AUTHENTICATION Communications by Web Browser Start up the Microsoft Internet Explorer and log in. This unit can communicate with a PC via Web browser. Live and pre-recorded images can be viewed from this 1. Start up the Microsoft Internet Explorer and enter the IP mode.
Communications by Web Browser (continued) 3-1. (If you make an error in entering the userID or password 1. Select the desired “Menu” and left-click. • • • ) • The “[Rejection]” screen appears. 3-2. Select “[Back to Authentication]” and either left-click or press ENTER.
Page 73
Setting “Transfer Rate” too far on “Hi” may present obstacles to PC operation as determined by the performance of the PC you are using. Please set it to the appropriate rate to the image retrieval speed of your machine. Depending on the network capacity and the load conditions, the transfer rate may not rise.
Page 74
Communications by Web Browser (continued) : Press to start reverse playback. : Press to start speed searches in the reverse direction at speeds of x2, x4, x8 and x16. : Press to frame-by-frame playback in the reverse direction. : During playback or searching, press to stop playback for still frame.
Page 75
4-1. (To register a new user • • • ) <User authorization> Enter the new userID and new password in “Register new user.” Live Monitor: 4-2. Refer to step 2-1, select the “access auth.” desired and Allows acquisition of live images. It is a mandatory check it.
Communications by Web Browser (continued) 3. Confirm that the desired time is set. • Change log in user This screen is for changing the logged in user. 1. Select “Change log in user” and left-click. • The “[Authentication]” menu appears. •...
Recording time table Continuous recording time table HDD continuous recording time (for 240 GB drive) Displays the estimated recordable time (when recording on a 240 GB (4R120L0 120 GB x 2) HDD). The following table shows estimated recordable time when operating with one camera and the recording interval is set at a constant PPS rate given at the top of the column.
Troubleshooting If problems with the unit persist even after you’ve followed the suggestions below, please disconnect the power cord and contact the retailer from whom you purchased the unit. Description of problem Please consult the following Page The unit is not turned on. •...
Page 80
Troubleshooting (continued) Description of problem Please consult the following Page The unit does not perform • Is “TRIGGER” of the camera number for which the motion the motion detection detection function is to be executed in the <ALARM SETTING> function. screen set to “EXT”? •...
Warnings and CALL OUT output Warnings and their appropriate countermeasures #1 Options in the CALL OUT output column: • Selectable : selects to output CALL OUT signal or not on the menu screen. • Fixed : outputs CALL OUT signal from the CALL OUT terminal regardless of the menu setting. •...
Glossary • Mirroring Glossary One way of protecting data on magnetic disks. This function writes data alternately to 2 Hard disk drives with the same • I/O terminals capacity. However, there is the demerit of using 2 drives in Terms used for referring to both input and output. place of 1, resulting in half the available space.
Specifications Rated Power Supply: AC 100 - 240 V 50/60 Hz Rated Input: 0.4 - 0.2 A (100 - 240 V) (with 2 HDDs described on page 14 attached ) Color System: PAL-type color system Operating Temperature: 5 C to 40 C Relative Humidity: Max.
Page 84
Others DEUTSCH STELLEN SIE NIEMALS SCHWERE GEGENSTÄNDE AUF DEN REKORDER (z. B. EIN FERNSEHGERÄT) STECKEN SIE NIEMALS GEGENSTÄNDE IN DEN REKORDER Gegenstände, die innen am Gehäuse anstoßen, oder alle eingesteckten Fremdkörper sind nicht nur gefährlich sondern verursachen auch große Beschädigung. SCHÜTZEN SIE DAS NETZKABEL Ein defektes Netzkabel kann Brand oder elektrischen Schlag verursachen.
Page 85
Others (Continued) FRANÇAIS INTERDICTION DE POSER DES OBJETS LOURDS SUR LE ENREGISTREUR (PAR EX: TÉLÉVISEUR) INTERDICTION DE TOUCHER L’INTÉRIEUR DE L’ENREGISTREUR ET D’Y INTRODUIRE TOUT CORPS ÉTRANGER Tout contact avec l’intérieur du boîtier ou toute introduction de corps étranger peut non seulement constituer un danger mais peut également entraîner d’importants dégâts.
Page 86
CASTELLANO NO COLOQUE NUNCA OBJETOS PESADOS SOBRE LA UNIDAD (P.E. TV) NO TOCAR NUNCA NI INSERTAR OBJETO ALGUNO EN EL INTERIOR DEL UNIDAD El tocar el interior de la caja o el insertar objetos extraños de cualquier clase no sólo crea peligros a la seguridad del usuario sino que también será...
Page 87
Others (Continued) ITALIANO NON COLLOCARE SULL’UNITÀ OGGETTI PESANTI (es. apparecchio TV) NON TOCCARE E NON INSERIRE OGGETTI ALL’INTERNO DELL’UNITÀ Toccare all’interno del mobiletto che contiene l’unità o inserire oggetti estranei, di qualsiasi tipo, oltre ad essere causa di pericolo per la sicurezza può condurre a danni onerosi. PROTEGGERE IL CAVO DI ALIMENTAZIONE ELETTRICA Il danneggiamento del cavo di alimentazione elettrica può...
Page 88
NEDERLANDS ZET IN GEEN GEVAL ZWARE VOORWERPEN BOVENOP DIT TOESTEL (BIJV. TV.) RAAK IN GEEN GEVAL ENIG VOORWERP IN HET TOESTEL AAN EN STEEK ER NIETS IN Aanraken van het binnenwerk, of naar binnen steken van voorwerpen die daar niet in thuishoren kan niet alleen gevaar opleveren, maar ook ernstige schade veroorzaken.
Page 89
Others (Continued) PORTUGES OBJETOS PESADOS NUNCA DEVEM SER COLOCADOS EM CIMA DO APARELHO (POR EX., TV) NÃO MEXA DENTRO DO APARELHO NEM INSIRA NELE QUALQUER OBJETO Tocar a parte interna do gabinete ou inserir objetos estranhos de qualquer natureza além de provocar um risco em termos de segurança, podem causar danos consideráveis ao aparelho.
Page 90
SVENSKA TUNGA FÖREMÅL (T EX EN TV) FÅR ABSOLUT INTE PLACERAS OVANPÅ ENHETEN RÖR INTE VID INSIDAN AV ENHETEN OCH STOPPA INTE IN NÅGRA FÖREMÅL I ENHETEN Om du rör vid insidan av skåpet eller stoppar in främmande föremål utsätter du inte bara dig själv för fara, utan kan även orsaka omfattande skador på...
Page 91
Others (Continued) РУССКИЙ ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Others...
Page 92
Fax: + 39 (0) 39-6053214 GERMANY The Netherlands Mitsubishi Electric Europe B.V. Mitsubishi Electric Benelux German Branch Office A Division of Mitsubishi Electric Europe B.V. Electric Visual Systems Niiverheidsweg 23A, 3641 RP Mijdrecht Gothaer Str. 8 40880 Ratingen Germany Netherlands. Telehone: +49 (2102) 486-9250...