Compact Dual Output EGC Amplifier A93270 and Compact Single
Output EGC Amplifier A93280 Housing Closure Instructions
Closing the Housing
Introduction
This document provides instructions for correctly closing the Compact Dual
Output EGC Amplifier A93270 and the Compact Single Output EGC Amplifier
A93280 housings.
Important: For complete information about Safety Instructions, Installation and
Operation of the Compact Dual Output EGC Amplifier A93270 or the Compact
Single Output EGC Amplifier A93280, refer to the Compact Dual Output EGC
Amplifier A93270 Installation and Operation Guide, part number 4029501, or the
Compact Single Output EGC Amplifier A93280 Installation and Operation
Guide, part number 4038501.
Tightening the Housing Closure Bolts
To tighten the housing closure bolts, follow the steps below.
Important: Before you start, make sure you have a 5-mm Allen wrench.
CAUTION:
Avoid moisture damage and RF leakage! Follow the procedure exactly as
shown below to ensure a proper seal.
1.
Inspect the housing gasket and all mating surfaces. Wipe off any dirt and
debris.
2.
Close the housing and finger-tighten all closure bolts.
3.
Use the Allen wrench to tighten each closure bolt from 5 Nm to 6.5 Nm (3.7 ft-
lb to 4.8 ft-lb).
Important: Follow this numbered sequence to tighten the closure bolts.
Continued on next page