hit counter script

Sync Control/Line-Lock Setup - Honeywell HCD92534 User Manual

True day/night ir camera ntsc/pal
Hide thumbs Also See for HCD92534:
Table of Contents

Advertisement

2.
Press the menu control UP, DOWN, LEFT, or RIGHT to select a character,
then press SETUP (MENU) to accept it. The character is saved and the title
cursor at the bottom of the screen moves to the next position. You can use
the
symbols to go back or forward in the title name to make changes,
" $
and you can also select CLR to delete the entire title and start again.
3.
Repeat
step 2
4.
Select POS to position where you would like the camera title to be located
on screen. Select the position using the menu control, then press (SETUP)
MENU to confirm the position.
5.
Select END when you are finished.

Sync Control/Line-lock Setup

This screen allows you to synchronize the vertical interval sync pulse of your
camera with other equipment to reduce the effect of picture roll on the monitor.
Linelock mode is only available when using 24 VAC power.
Figure 7
Menu Item
Description
INTERNAL
When line lock is not required.
LINELOCK
Adjust the vertical phase (VPH):
VPH: 000–359 (factory default is 0)
RETURN
Press MENU to return to the SETUP MENU.
18
until your camera title is complete.
Sync Control Setup
<SYNC. CONTROL>
SYNC
INT (L/L)