▀ Information Required to Configure the System as an HNB-GW
Required Information
Description
Peer Server Process
Specifies the peer server process instance in peer server id. The instance must be an integer from 1 to 4.
(PSP) instance
A PSP instance configuration need to define:
Signaling Connection Control Part (SCCP) Network Instanc Configuration
SCCP Network
An identification for SCCP network instance and must be an integer between 1 and 12 by which the SCCP
Instance and variant
network instance will be identified and configured.
A variant can be configured for the SS7 routing domain. some of them are:
SS7 Routing
An identification for SS7 routing domain and must be an integer between 1 and 12 by which the SS7
Domain id and
routing domain will be identified and associated with this SCCP network instance.
variant
Destination point
Specifies the destination point code (DPC) in SS7 address format along with SSN and SCCP version.
code
Circuit Switched Network Configuration
Circuit Switched
An identification string between 1 and 63 characters (alpha and/or numeric) by which the Circuit Switched
Network instance
Core Networks instance which needs to be associated with HNB Radio Network PLMN id.
An HNB-CS network instance is required for Femto UMTS access over IuCS/IuFlex interface between
HNB-GW service and CS networks elements; i.e. MSC/VLR.
Multiple CS network instances (maximum 8) can be configured on a system.
SCCP Network id
Specifies a predefined Signaling Connection Control Part (SCCP) network id in at system level in Global
configuration mode to be associated with the CS network instance in order to route the messages towards
MSC/VLR over IuCS interface.
RTP IP Pool name
An identification string from 1 to 63 characters (alpha and/or numeric) by which the RTP pool is
configured and associated with CS network configuration to allocate RTP IP address over IuCS towards
CS core networks.
Default MSC point
Specifies the default MSC point-code with HNB-CS network instance. This MSC point code (SS7 address)
code
is used when HNB-GW is to be connected to only one MSC with in a CS network or as default MSC for
all HNBs connected through specific HNB-CS network instance.
Packet Switched Network Configuration
▄ Cisco ASR 5000 Series 3G Home NodeB Gateway Administration Guide
PSP mode: client or server
Exchange mode: double ended or single ended
End point address in SS7 address format
Association of ASP instance
ansi: American National Standards Institute (U.S.A.)
china: Chinese standard
itu: International Telecommunication Union (ITU-T) Telecommunication Standardization Sector
ntt: Japanese standard
ttc: Japanese standard