EMU00435*
ENGINE FAILS TO OPERATE
In the unlikely event of an ignition control
system malfunction, the engine speed
may become erratic or the engine may
stop.
In such a case, follow the procedure
below.
1) Remove the electric cover 1.
F1025A
2) Disconnect the connection of the yel-
low cord 2 (emergency circuit) to
return to the nearest port.
w
When the connection is disconnected, the
idling and low speeds are slightly higher
than normal. Use care when starting off
or stopping.
cC
F1046
Follow this procedure only in an emer-
gency and just long enough to return to
port for repairs.