Headphones level reduction Delegate unit modes 7.4.1 Single delegate 7.4.2 Chairman 7.4.3 Single delegate with auxiliary control Operation Microphone Attendance LED Troubleshooting Delegate Unit Maintenance 10.1 Cleaning 10.2 Storage Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
Page 4
| Table of Contents DCN-D Conference Delegate Units Technical Data F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
Please read the Important Safety Instructions before you install or operate the delegate units and the DCN System. The Important Safety Instructions are supplied together with the central control unit. Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
The Installation and Operation manual gives installers and operators the necessary data to install, configure, operate and maintain the following delegate units: – DCN-DS-xx (Delegate unit with fixed short stem microphone). – DCN-DL-xx (Delegate unit with fixed long stem microphone).
Figure 3.1 Top view of the basic delegate unit (DCN-DS/L) and the delegate unit with channel selector (DCN-DCS) Bosch Security Systems B.V.
Page 8
Figure 3.2 Top view of the delegate unit with voting (DCN-DV) and with channel selector (DCN-DVCS) F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
Page 9
NOTICE! A DCN-MICL or DCN-MICS pluggable microphone cannot used with the DCN-DS and DCN-DL delegate units. The DCN-DS and DCN-DL delegate units have fixed microphones. Loudspeaker - Gives the audio signal from the floor to the delegate or the chairman unit.
Page 10
13. De-init switch - Erases the address of the delegate unit. – All LEDs on the delegate unit are on when the delegate unit does not have an address. Figure 3.5 Delegate unit bottom view F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
The following table shows the power consumption of each delegate unit type used in the DCN system. Delegate unit Watt DCN-DS 2.75 DCN-DL 2.75 DCN-CS DCN-DV 3.05 DCN-DVCS 3.20 Table 4.1 Power consumption Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
To remove the microphone button (1), push the button tool trough the bottom side holes as indicated. – The tool comes with the DCN-DBCM button (2) set (to be ordered separately). Figure 5.2 Remove the microphone button (1) F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
When you attach the delegate unit to a flat surface, put screws with a maximum length of 8 mm in the screw holes (11). The distance between the centres of the screw holes is 34 mm. Figure 5.4 Installation to a flat surface Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
DCN-DISCLM cable-to-unit clamp to be ordered separately. Plug cable and clamp into the unit: Clockwise rotate clamp and make clamp snap into the locking hole of the rear panel: F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
Do not use a sharp object, otherwise you might damage the de-initialization switch. Use a paperclip or similar device to push the de-initialization switch. Figure 7.1 De-initialization switch Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
The LED above the microphone button come on as red. – The channel 0 (floor) is automatically set. – The volume is automatically set to -18 dB. Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
Refer to Section 7.4.2 Chairman. Single delegate with auxiliary control Refer to Section 7.4.3 Single delegate with auxiliary control. Table 7.3 Delegate unit mode overview Figure 7.3 Delegate unit mode switches F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
NOTICE! The DCN-DBCM button set comes with a tool that you can use to remove the buttons from the delegate unit. Refer to Section 5 Installation. Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
Refer also to Section 5 Installation. CAUTION! The DCN-DS/L and DCN-DCS delegate units do not support the single delegate with auxiliary control mode. When this mode is set, the delegate unit will be operate as single user. F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
The LED adjacent to voting button 1 is the attendance LED. Attendance LED Condition Yellow (flashing) The system requests attendance registration. Yellow (on) The attendance registration is confirmed. Table 8.2 Attendance LED Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
DCN system. – A delegate unit does not operate as The delegate unit is not in the correct expected. mode. Refer to Section 7.4 Delegate unit modes. F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.
Let the delegate unit fully dry before you install it again. 10.2 Storage Keep the delegate units in a clean and dry area with a sufficient airflow. Bosch Security Systems B.V. Installation and Operation manual F.01U.265.631 | V1.0 | 2012.03...
- DCN-CS-xx 1.15 kg (2.54 lb) - DCN-DV-xx 1.15 kg (2.54 lb) - DCN-DVCS-xx 1.15 kg (2.54 lb) Color top Black (RAL 9017) Color rear Silver (RAL 9006) F.01U.265.631 | V1.0 | 2012.03 Installation and Operation manual Bosch Security Systems B.V.