Table of Contents | en Table of Contents Trademarks Door Profile Strike Profile Event Profile Notes Program Record Sheets Profiles 5.1.1 Door Profiles 5.1.2 Strike Profiles 5.1.3 Event Profiles Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10...
This document describes the parameters available to the security panel for programming the D9210C Access Control Interface. For a description of the theory of operation and the actual operation of the unit, please refer to the D9210C Operation and Installation Guide (P/N: F01U215244).
Blank Selections: Blank, 1-8 Assign an area to the door controller. This entry allows the D9210C to be polled activating communication to the panel. This also is the area a user will exit when initiating a Request to Exit [REX].
Page 6
The interlock point will be considered in a normal state if it is bypassed swinger bypassed or forced armed. This will result in normal operation of access even if the door is left open. F.01U.201.526 | 02 | 2011.10 Program Entry Guide Bosch Security Systems, Inc.
Page 7
Use this program item to determine whether the door needs to be physically opened prior to disarming the area upon a valid access request. The user initiating the access request must have access levels that allow disarming with ID. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10...
Page 8
No The area will disarm whether or not the door has been opened as soon as a user with a valid disarm level has presented a valid token/card. F.01U.201.526 | 02 | 2011.10 Program Entry Guide Bosch Security Systems, Inc.
The buzzer will stop as soon as the door is opened. NOTICE! A separate buzzer is required. Many readers have an internal buzzer that is not affected by Buzz Time. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10...
Page 10
D# RTEShunt Only? Default: Selections: Yes or No Use this program item to disable the strike, but still activate the programmed shunt time upon a Request to Enter an area. F.01U.201.526 | 02 | 2011.10 Program Entry Guide Bosch Security Systems, Inc.
Page 11
No Request to Exit [REX] automatically activates the programmed strike and shunt time. NOTICE! When REX Shunt Only is [Yes] Request To Exit events are not logged, reported, or printed. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10...
Yes Access denied events from this door controller will be sent to the panel for processing. No Access denied events from this door controller will not be sent to the panel for processing. F.01U.201.526 | 02 | 2011.10 Program Entry Guide Bosch Security Systems, Inc.
Page 13
No A DOOR REQUEST TO EXIT event from this door controller is not sent to the panel for processing. NOTICE! REX events require D# Access Granted to be programmed [YES]. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10...
Address City / State / Zip Premises phone Installer name Door # Point # Point Text Location Door #’s 3 through 8 for D9412 Family only Control/Communicator Location Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10...
Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Exit Request? Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Doors 3 through 8 are available for the D9412 Family only. F.01U.201.526 | 02 | 2011.10 Program Entry Guide Bosch Security Systems, Inc.