hit counter script
Download Print this page

Advertisement

Available languages

Available languages

Quick Links

MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See "Installation
Requirements" section for further notes.
These installation instructions
cover different models. The appearance of your particular model may differ slightly from the illustration in
these installation instructions.
INSTR UCTI O NS.D'INSTALLATI O N
DE L'ENSEMBLE FOURA MICRO-ONDES/HOTTE
Ce produit
est con(_u pour I'utilisation
au-dessus
d'appareils
de cuisson
electriques
ou & gaz de 36" (91,4 cm) de largeur ou moins.
Voir la
section
"Exigences
d'installation"
pour d'autres
remarques.
Ces instructions
d'installation
sont valables
pour plusieurs
modeles.
II se peut que I'apparence
de votre
propre
modele
soit legerement
differente
de celle montree
sur les illustrations
dans ce document.
Table of Contents / Table des mati@res
MICROWAVE
HOOD COMBINATION
SAFETY ....................... 1
INSTALLATION
REQUIREMENTS
............................................
2
Tools and Parts ......................................................................
2
Remove Cardboard Template ...............................................
2
Location Requirements ..........................................................
2
Product Dimensions ...............................................................
3
Electrical Requirements
.........................................................
3
INSTALLATION
INSTRUCTIONS
..............................................
4
Remove Mounting Plate .........................................................
4
Rotate Blower Motor ..............................................................
4
Locate Wall Stud(s) ................................................................
6
Mark Rear Wall .......................................................................
7
Drill Holes in Rear Wall ...........................................................
7
Attach Mounting Plate to Wall ...............................................
8
Prepare Upper Cabinet ..........................................................
8
Install Damper Assembly .......................................................
9
Install the Microwave Oven ....................................................
9
Complete Installation ...........................................................
10
VENTING DESIGN SPECIFICATIONS
...................................
11
ASSISTANCE ...........................................................................
12
Replacement
Parts ...............................................................
12
Accessories ..........................................................................
12
SECURITE DE L'ENSEMBLE FOUR .&.MICRO-ONDES/HOTTE...13
EXIGENCES D'INSTALLATION
.........................................................
13
Outillage et pieces ...........................................................................
13
Deposer du gabarit de carton .........................................................
14
Exigences d'emplacement
..............................................................
14
Dimensions du produit ....................................................................
14
Specifications
electriques ...............................................................
15
INSTRUCTIONS
D'INSTALLATION
..................................................
15
Depose de la plaque de montage ...................................................
15
Reorientation du moteur du ventilateur ..........................................
15
Identifier la position du/des poteau(x) du colombage
mural .......... 17
Trace sur lemur arriere ...................................................................
18
Pergage de trous dans lemur arriere ..............................................
19
Fixation de la plaque de montage sur lemur .................................
19
Preparation du placard mural ..........................................................
20
Installation du module du clapet anti-reflux .................................... 20
Installation du four & micro-ondes
..................................................
21
Achever I'installation ........................................................................
22
SPECIFICATIONS
DU CIRCUIT D'EVACUATION
........................... 23
ASSISTANCE ......................................................................................
24
Pieces de rechange .........................................................................
24
Accessoires .....................................................................................
24
MICROWAVE HOOD COMBINATION SAFETY
Your safety and the safety of others are very important.
We have provided
many
important
safety
messages
in this manual
and on your
appliance.
Always
read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
W10238255A

Advertisement

loading

Summary of Contents for Whirlpool w1023b255a

  • Page 1 MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See "Installation Requirements" section for further notes. These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration in these installation instructions.
  • Page 2 INSTALLATIONREQUIREMENTS t'O0_S 3_J Tools Needed The cardboard piece from the top of the microwave oven packaging is perforated. The piece inside the perforation is for use Gather the required tools and parts before starting installation. as a rear wall template. Read and follow the instructions provided with any tools listed here.
  • Page 3 Installation Dimensions NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See "Electrical Requirements" section. l ..Electrical Shock Hazard Plug into a grounded 3 prong outlet. 30" (76.2 cm) typicam* 12" (30.5 cm) rain. Do not remove ground prong. 14"...
  • Page 4 INSTALLATIONINSTRUCTIONS 2. Keep damper plate and screws together and set aside. 3. Remove 2 screws attaching blower motor to back of microwave oven. Depending on your model, the mounting plate may be in the foam packaging, or it may be attached to the back of the microwave oven.
  • Page 5 Reattach damper plate. Make sure damper plate tabs are IMPORTANT: If blower motor is not positioned with flat sides inserted into the slots in the top of the microwave oven. facing the back of the microwave oven (as shown), performance will be poor.
  • Page 6 NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within install the microwave oven. the opening. See illustrations in "Possible Wall Stud Configurations." 2. Mark the center of each stud, and draw a plumb line down each stud center.
  • Page 7 5. With the support tabs facing forward (see illustrations in "Locate Wall Stud(s)" section), align the mounting plate center markers to the centerline on the wall, making sure its bottom The microwave oven must be installed on a minimum of 1 wall edge is aligned to the horizontal line drawn in Step 3, and that stud, preferably 2, using a minimum of 1 lag screw, preferably 2.
  • Page 8 Insert lag screw(s) into the hole(s) drilled into wall stud(s) in Installation for Wall Stud at One End Hole (Figure 3) Step 2 of "Installation for No Wall Studs at End Holes" in the "Drill Holes in Rear Wall" section. 1.
  • Page 9 5. Cut the 11/2"(3.8 cm) diameter hole at the circular shaded area "G" on the template. This hole is for the power supply cord. NOTE: If upper cabinet is metal, the supply cord bushing needs to be installed around the supply cord hole, as shown. Excessive Weight Hazard Use two or more people to move and install microwave oven.
  • Page 10 5. Rotate m icrowave oven uptoward u pper c abinet. 2. Connect vent to damper assembly. NOTE: Ifventing t hrough t hewall, m ake sure thedamper assembly fitseasily i ntothevent i nthewall c utout. 6. Push microwave oven against mounting plate andhold in place.
  • Page 11 VENTING DESIGN SPECIFICATIONS This section is intended for architectural designer and Rectangular to Round Transition builder/contractor reference only. NOTE: The minimum 3" (7.6 cm) clearance must exist between NOTES: the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully.
  • Page 12 Recommended Vent Length A 31/4 '' x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent 6" (15.2 cm) vent system = 73 ft (22.2 m) total should be used. The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent.
  • Page 13 SECURITE DE L'ENSEMBLE FOURA MICRO-ONDES/HOTTE Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s6curit6 importants dans ce manuel et sur votre appareil m6nager. Assurez-vous toujours lire tous les messages de s6curit6 et de vous y conformer. Ce symbole d'alerte de s6curit6 vous signale les dangers potentiels de d6c_s et de blessures graves &...
  • Page 14 Dimensions _ respecter Iors de I'installation REMARQUE : La prise de courant &3 alveoles reliee a la terre doit 6tre situ6e & I'interieur du placard mural. Voir la section Le morceau de carton du dessus de I'emballage du four & micro- "Specifications electriques".
  • Page 15 INSTRUCTIONS DE LIAISON .&,LA TERRE Pour tout appareil m_nager connect_ par un cordon de courant _lectrique II faut que le four & micro-ondes soit reli_ & la terre. En cas de court-circuit _lectrique, la liaison & la terre r_duit le risque de choc _lectrique car le courant _lectrique dispose d'un itin@aire direct d'acheminement &...
  • Page 16 2. Conserver ensemble la plaque de support du clapet et les vis. Pour une installation avec d_charge & I'ext_rieur 3. Retirer les 2 vis fixant le moteur du ventilateur a I'arriere du travers le toit seulement four a micro-ondes. Rep6ter I'etape 1 de "Pour une installation avec decharge murale seulement".
  • Page 17 ......mu '@ REMARQUE : 8'il n'y a aucun poteau du colombage mural dans 1. Utiliser un detecteur magnetique de clou/vis pour Iocaliser la zone delimit6e par I'ouverture dans le placard mural, ne pas dans I'ouverture les rives du/des poteau(x) du colombage installer le four _ micro-ondes, mural.
  • Page 18 Le four & micro-ondes dolt _tre fixe sur au moins un poteau du • L'axe de la rive inferieure dolt _tre situe & 171/4 '' (43,8 cm) colombage mural, et de pref6rence sur 2 poteaux; on utilise pour de la partie inferieure du cabinet superieur et dolt _tre cela au moins 1 vis d'ancrage, et de pr6ference 2 vis.
  • Page 19 Engager un ecrou articule sur chaque vis par I'arriere de la plaque de montage. Veiller a disposer de suffisamment ..tsc us d< sns d'espace pour que les ecrous articules puissent traverser le En plus de la fixation sur au moins un poteau du colombage, panneau de gypse et se deployer a I'interieur de la cavite doit egalement fixer la plaque de montage sur le tour au niveau murale.
  • Page 20 S'il est possible de fixer egalement I'appareil sur un second REMARQUE : Si le placard mural est metallique, la garniture de cordon d'alimentation necessite d'etre installee autour du trou de poteau du colombage mural, inserer une vis d'ancrage dans I'autre trou perce & I'etape 2 du paragraphe "Un trou d'angle passage du cordon d'alimentation -voir I'illustration.
  • Page 21 4. Alors que I'avant du four & micro-ondes est encore incline, enfiler le cordon d'alimentation & travers le trou de passage perce dans le fond du placard mural. Risque du poids excessif Utiiiser deux ou plus de personnes pour d_placer et installer le four _ micro=ondes.
  • Page 22 Pour une installation avec d_charge & I'ext_rieur travers le toit seulement 1. Installer les filtres. Voir les Instructions d'utilisation pour la mise en place des filtres. 1. Inserer le module du clapet anti-reflux a travers I'ouverture decoup6e dans le placard mural, de telle maniere que la patte Iongue du module du clapet anti-reflux puisse glisser sous les pattes d'arrimage relevees de la plaque de support du clapet.
  • Page 23 SPECIFICATIONS DU CIRCUIT D'EVACUATION Cette section presente de I'information de ref6rence uniquement, Raccord de transition rectangulaire/rond I'intention des architectes/concepteurs et constructeurs. REMARQUE : On doit disposer d'un espace libre de 3" (7,6 cm) REMARQUES : ou plus entre le sommet du four a micro-ondes et le raccord de transition rectangulaire/rond pour que le clapet anti-reflux puisse...
  • Page 24 Longueur recommand_e ducircuitd'_vacuation On doit utiliser un conduit rectangulaire de 31¼"x 10" (8,3 x Circuit d'_vacuation de dia. 6" (15,2 cm) = Iongueur totale 25,4 cm), ou un conduit rond de dia. 6" (15,2 cm). 73 pi (22,2 m) La Iongueur totale du circuit d'evacuation, ceci incluant les sections de conduit rectilignes, coude(s), raccords de transition et bouche de decharge murale ou sur toit, ne doit pas depasser...