Kenmore PRO 233.51063600 Use & Care Manual

Kenmore PRO 233.51063600 Use & Care Manual

30" & 36" wide - stainless

Advertisement

Available languages

Available languages

Quick Links

T(Vl
ange Hood
Use & Care Guide
InstallationManual
Campana
de cocina
Manual de uso y cuidado
Manual de instalaci6n
Models
233.51003600
(30" wide - Stainless)
Modelos
233.51063600
(36"wide
- Stainless)
HBO057
i"n
z
t.=
m
¢0
"r
ITI
Zl
0
r.=
V07800 rev. B
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com

Advertisement

loading

Summary of Contents for Kenmore PRO 233.51063600

  • Page 1 T(Vl ange Hood Use & Care Guide InstallationManual i"n Campana de cocina ¢0 Manual de uso y cuidado "r Manual de instalaci6n Models 233.51003600 (30" wide - Stainless) Modelos 233.51063600 (36"wide - Stainless) HBO057 V07800 rev. B Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com...
  • Page 2 (Cr&pes Suzette, Cherries Jubilee, 7. To reduce the risk of fire and electric shock, the Kenmore Peppercorn Beef Flambe). PRO 51000 Series hood must be installed with blower 3. Clean ventilating fans frequently. Grease should not be models 51200,...
  • Page 3 Always t urn ONyourhood before y oubegin cooking i norder Baffle filters toestablish anairflowinthekitchen. Lettheblower runfora The baffle filters should be cleaned frequently. Use a warm fewminutes toclear t heairafter y outurnofftherange. This detergent solution. Baffle filters are dishwasher safe. willhelp keep thewhole kitchen c leaner andbrighter.
  • Page 4 Baffle Filter (3perhood) Parts Bag (includes 4 flat head screws #10-2", Ducting Accessories 8 screws #8-3A', 4 Nuts #10-32, (See "51000 Series Range Hood System" on page 5 for 2 Wall anchors and Ducting Accessory Model Nos.) 2 Washers 3/16'ID x sA"OD) Blower (interior OR exterior) 120V,...
  • Page 5 Wall& Roof Caps, Exterior Blower Sears Stock Broan Model Brean Model Broan Model 647 Sears Stock Humber 57745 7" Round Number 59091 1200 cfm High Capacity 10" Round Wall Cap Roof Cap Exterior Blower Roof Cap Wall Cap Elbows and In-Line Dampers Broan Model 418 Broan Model 421...
  • Page 6 Kenmore range hoods are designed to perform efficiently when attached to long runs of duct. As a point of reference, this hood will function at approximately 80% of its rated air performance when 100 equivalent feet of 7" round ductwork is attached (for 600 cfm blowers) or 125 equivalent feet of 10"...
  • Page 7 1. The Kenmore PRO Series hood must be installed with 2. Dimensions for the most common installations are shown interior blower models 51200 or 51600, or exterior blower below. 57745 only. Other blowers cannot be substituted. Adjust your measurements for various heights of ceilings, (Blowers sold separately.)
  • Page 8 1. Measure and mark a level line on wall above cooktop location for the wood mounting strip (see illustration to the right and under step 2 on page 7). Unscrew the mounting strip from the hood and discard the screws. Use #10=2"...
  • Page 9 1. Rest the back cavity of the hood on the wood mounting strip. CAUTION: Hold the hood until it is completely secured to the wood mounting strip. Secure hood to wood strip with (4) screws #8 - 3A" provided at location shown. Drill (2) 3h6" size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown.
  • Page 10 1. Remove wiring cover from rough-in plate and set aside. WARNING: Risk of electrical shock. Electrical wiring must be done by qualified personnel 2. Remove appropriate knock-out from rough-in plate. As you in accordance with all applicable codes and are installing the rough-in plate, feed 6"...
  • Page 11 CAUTION: Remove protective plastic film covering baffle filters before installing them. It is recommended to install side baffle filters first and finish with center one. HD0172 1) Insert one end of baffle filter into the hood. Push towards the front of the hood in order to insert the retaining clip into the baffle border slots.
  • Page 12 30" WIDTH 36" WIDTH V13924 Male Connector V13923 Female Connector V07452 Control Processor Unit V07679 Logo Kenmore V 16569 Lamp Shell, Socket &Trim Ass'y V05921 Halogen Lamp (50W, 120V, PAR 16, GU-10) V07664 Electronic Control Ass'y V06138 Thermistor Heat Sentry...
  • Page 13: Installation

    Your Home For repair-in your home-of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances...
  • Page 14 7. Parareducirelriesgodeincendioydechoqueelectrico, lascampanas de la serie PRO 51000 de Kenmore deben instalarse unicamente los ventiladores impelentes 51200, 51600 o 57745 y no deben sustituirse por otros ventiladores. Los ventiladores impelentes se venden aparte.)
  • Page 15 Filtros Ponga en marcha siempre la campana antes de empezar a cocinar para generar una corriente de aire en la cocina. Los filtros deben limpiarse con frecuencia. Utilice una disoluci6n Deje en marcha el ventilador durante unos minutos para de detergente con agua templada. Los filtros se pueden lavar renovar el aire una vez que haya apagado la cocina.
  • Page 16 Regleta de montaje Filtro (3 para campana) Bolsa de piezas (4 tornillos de cabeza plana n.° 10 de 2 pulg., Accesorios para tubes 8tornillos n.°8 de sApulg., (const_ltese la secci6n "Sistema de campanas de cocina de 4 tuercas n.° 10-32, 2 dispositivos de la serie 51000"...
  • Page 17 C apuchones murales y de tejado, Ventilador exterior Pieza Sears Broan modelo 437 Broan Broan modelo 647 Pieza Sears numero 57745 n(imero 59091 Capuch6n modelo 441 Capuch6n mural Ventilador exterior alta capacidad Capuch6n mural redondo de 7 pulg. Capuch6n para tejado de 12001pcm para __tejad°...
  • Page 18 Lascampanas de Kenmore hansidodiseihadas para funcionar eficazmente cuando estb_n conectadas contuboslargos. Amodo dereferencia, esta campana funcionara aproximadamente al80%desurendimiento evaluado cuando e ste conectada conelequivalente de100 pies detubo redondo de7 pulgadas dedia.metro (para ventiladores de600 pies cubicos p orminuto) o conelequivalente de125piesdetuboredondo de10pulgadas dedia.metro (para ventiladores de1200 pies cubicos p or minuto).
  • Page 19 1. Las campanas delaserie PRO 51000 deKenmore deben 2. Abajo se indican las dimensiones para las instalaciones instalarse conlosventiladores interiores 51200 o 51600 mAs habituales. ocon elventilador exterior 57745, que nodeben s ustituirse Ajuste las medidas a los distintos tipos de altura del techo, porotros v entiladores.
  • Page 20 1. Mida y marque una Ifnea a nivel en la pared per encima de la superficie de cocci6n para la regleta de montaje (vease la ilustraci6n de la derecha y la de la etapa 2 de la pa.gina 19). Destornilla la regleta de montaje de la campana y tira los tomillos.
  • Page 21 1. Coloque el hueco trasero de la campana sobre la regleta de montaje de madera. PRECAUCI6N: Sujete la campana hasta que est_ totalmente asentada contra Ja regleta montaje. Sujete la campana a la regleta de montaje colocando PARTE SUPERIOR DE LA CAMPANA (4) tornillos n.°...
  • Page 22 ADVERTENCIA: Riesgo de choque el6ctrico. 1. Retire la tapa del cableado de la placa del ventilador y p6ngala a un lado. La conexi6n el6ctrica debe hacerla personal competente con arreglo a los c6digos 2. Quite la pieza desmontable apropiada de la placa del normas en vigor.
  • Page 23 PRECAUCION: Retire la pelfcula protectera plastico que cubre los filtros antes de instalar estos. Se aconseja instalar primero los filtros laterales y terminar con el filtro central. £ HD0172 1) Introduzca un extreme del filtro en la campana. Empuje hacia la parte delantera de la campana para que el clip de retenci6n se introduzca en las ranuras del borde del filtro.
  • Page 24 Montaje de cuadro interior (incluye arte clave n.° 9) 30"x 18"x 24" V16693 Montaje de cuadro interior (incluye arte clave n.° 9) 36"x 18"x 24" V07678 Cableado V07800 Manual de instalaci6n de Kenmore V12971 Bolsa con piezas para la instalaci6n (4 tornillos n.° 10 de 2" de cabeza plana, 8 tornillos n.