5-13. Adding patterns created using the programming software for
electronic pattern sewer
You can use the programming software for electronic pattern sewer to create your own sewing patterns.
Up to nine of the patterns which you create in this way can be programmed into a P-ROM.
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the face plate of the control box. Touching areas where high voltages are present can result in
severe injury.
3944Q
1. Remove the six screws (1), and then open the cover (main P.C. board mounting plate (2)).
Note: When opening the cover, hold it securely so that it does not fall down.
2. Remove the P-ROM (3) from the main P.C. board.
3. Create the pattern(s) using the programming software for electronic pattern sewer. Refer to the Operating
Instructions for the programming software for electronic pattern sewer for details on how to create patterns.
4. Add the pattern(s) created to the P-ROM (3).
5. Install the P-ROM (3) to the main P.C. board so that it faces as shown in the illustration.
Note: If attached in reverse way, P-ROM may be damaged.
6. Close the cover (main P.C. board mounting plate (2)), and tighten the six screws (1).
The program numbers for patterns which have been created using the programming software for electronic pattern
sewer range from P1 to P9. However, program numbers which have not yet been assigned to a program will not appear
on the program number LED.
→ 1→ 2→ 3→......→ 90→ P1→ P2→......→ P9
You can check and change the following parameters for patterns which have been created using the programming
software for electronic pattern sewer.
No.
Setting items
00
Sewing speed (zigzag part)
02
Length of knife
08
Knife X position alignment
09
Knife Y position alignment
16
Running speed (Straight bar tack)
48
Underlay speed
60
Slow speed
61
Rear tack speed
62
Front tack speed
DANGER
Setting range
1,000 - 4,000rpm
Value is for checking purposes
and cannot be changed.
-0.5 - 0.5mm
-0.8 - 0.8mm
1,000 - 3,000rpm
1,000 - 3,000rpm
500 - 1,500rpm
500 - 4,000rpm
500 - 4,000rpm
HE-800A
5. OPERATION
3945Q
Unit
Default
100
3,600
-
0.1
0.0
0.1
0.0
100
2,000
100
2,000
100
800
100
4,000
100
4,000
54
-