SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit Outdoor unit ASYB09LDC AOYS09LDC ASYB12LDC AOYS12LDC CONTENTS SPECIFICATIONS ..... 1 DIMENSIONS .
SPECIFICATIONS DIMENSIONS 283 x 790 x 230 mm INDOOR UNIT TYPE COOL & HEAT INVERTER H x W x D 540 x 790 x 290 mm ASYB09LDC ASYB12LDC OUTDOOR UNIT INDOOR UNIT H x W x D AOYS09LDC AOYS12LDC OUTDOOR UNIT WEIGHT 2.60 kW 3.50 kW...
CIRCUIT DIAGRAM Models : ASYB09LDC / AOYS09LDC ASYB12LDC / AOYS12LDC INDOOR UNIT FAN MOTOR DISPLAY BOARD BLACK BROWN CN11 CN10 GREEN / YELLOW SWITCH AIR CLEAN UNIT OUTDOOR UNIT REACTOR REACTOR COMPRESSOR R(U) WHITE WHITE S(V) WHITE WHITE BLACK C(W) BLACK THERMISTOR (PIPE) BLACK...
Page 6
PCB Circuit Diagrams not available at time of publication...
ERROR CONTENTS Display Error Error Operation Timer LED 2 flash Serial signal (reverse) error, at operation start up 3 flash Serial signal (reverse) error, during operation Serial signal error 4 flash Serial signal (forward) error, at operation start up 5 flash Serial signal (forward) error, during operation 2 flash Indoor temperature thermistor open / short...
STANDARD ACCESSORIES Name and Shape Part No. Wall hook bracket 9310001004 Remote control unit INVERTER 9315027047 Remote control unit holder 9305642045 Battery (penlight) 0600185527 Cloth tape 9310519004 Tapping screw (big) 4 x 25) 0700076046 Tapping screw (small) 3 x 12) 0700019036 Air cleaning filter 9312153015...