PRODUCT MODEL NUMBER
KUIC15NLX
KUIC15PLX
KUIC15NRX
KUIC15PRX
Electrical: A 115 Volt, 60 Hz., AC only, 15- or 20-amp electrical supply,
properly grounded in accordance with the National Electrical Code and local
codes and ordinances, is required.
It is recommended that a separate circuit, serving only your ice maker, be
provided. Use a receptacle which cannot be turned off by a switch or pull
chain.
IMPORTANT: If this product is connected to a GFCI (Ground Fault Circuit
Interrupter) equipped outlet, nuisance tripping of the power supply may
occur, resulting in loss of cooling. Food quality and flavor may be affected. If
nuisance tripping has occurred, and if the condition of the food appears poor,
dispose of it.
Water: A cold water supply with water pressure between 30 and 120 psi
(207 and 827 kPa) is required to operate ice maker and water dispenser. If
you have questions about your water pressure, call a licensed, qualified
plumber.
Reverse Osmosis Water Supply:
Reverse osmosis water filtration systems can be used only with ice maker
installations that have a gravity drain. A reverse osmosis system is not
recommended for ice makers that have a drain pump installed.
The pressure of the water coming out of a reverse osmosis system going
to the water inlet valve of the ice maker needs to be between 30 and
120 psi (207 and 827 kPa). If a reverse osmosis water filtration system is
connected to your cold water supply, the water pressure to the reverse
osmosis system needs to be a minimum of 40 to 60 psi (207 and
827 kPa).
Location:
To ensure proper ventilation for your ice maker, the front side must be
completely unobstructed. The ice maker may be closed-in on the top and
three sides, but the installation should allow the ice maker to be pulled
forward for servicing if necessary.
Installation of the ice maker requires a cold water supply inlet of
(6.35 mm) OD soft copper tubing with a shutoff valve and either a gravity-
drain system or condensate pump to carry the water to an existing drain.
Choose a well ventilated area with temperatures above 55°F (13°C) and
below 110°F (43°C). Best results are obtained between 70°F (21°C) and
90°F (32°C).
DRAIN REQUIREMENTS
A. Water supply tube clamp
B. Vent hose (drain pump models only)
C. Inlet water tube clamp and supply
line connector
D. Drain hose (drain pump models only)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Ice Maker

KUIS15NRX
"
1
4
A
B
C
1⁷⁄₈"
(4.8 cm)
D
23"
(58.4 cm)
A. Drain hose
D. Center of drain should be 23" (58.4 cm)
B. 1" (2.54 cm)
air gap
C. PVC drain
reducer
CABINET OPENING DIMENSIONS
34"
(86.4 cm)
Min.
34 "
(87.6 cm)
Max.
A. Recommended location for
B. Floor level
Be sure the power supply cord is not pinched between the ice maker and
the cabinet.
Be sure the water supply line is not pinched between the ice maker and the
cabinet.
Be sure the drain line (on some models) is not pinched between the ice
maker and the cabinet.
Choose a location where the floor is even. It is important for the ice maker
to be level in order to work properly.
1" (2.54 cm)
2" - 1¹⁄₂"
(5 cm - 3.8 cm)
from front of door, with or without the
" (1.91 cm ) panel on the door. The
3
4
drain should also be centered from left
to right (7
5
" [18.56 cm] from either
16
side of the ice maker).
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
11 "
(29.2 cm)
9"
3
"
(22.9 cm)
(8.9 cm)
24"
(60.1 cm)
15"
(38.1 cm)
electrical and plumbing fixtures.
Drain: Either a gravity-drain system or
condensate pump to carry water to an
existing drain.
Drain lines must have a minimum of
(15.88 mm) inside diameter.
A
Drain lines must have a 1" drop per 48"
(2.54 cm drop per 122 cm) of run or
drop per 12" (6.35 mm per 30.48 cm)
B
of run and must not have low points
where water can settle.
The floor drains must be large enough
to accommodate drainage from all
drains.
The ideal installation has a standpipe
C
with a 1
1
" (3.81 cm) to 2" (5.08 cm)
2
PVC drain reducer installed directly
D
below the outlet of the drain tube as
shown. You must maintain a 1" (2.54
cm) air gap between the drain hose
and the standpipe.
It may be desirable to insulate the drain
line thoroughly up to the drain inlet.
A
28 "
(72.4 cm)
B
5
"
8
"
1
4
Ref. W10282144A
5/11/12