Warnings and cautions WARNING! Any surface or area of the equipment marked with this symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. To reduce the risk of injury from a hot component, enable the surface to cool before touching. WARNING! Any surface or area of the equipment marked with this symbol indicates the presence of an electrical shock hazard.
Page 3
CAUTION: To prevent damage to the workstation, observe the following Electrostatic Discharge (ESD) precautions while performing the system parts removal and replacement procedures: — Work on a static-free mat. — Wear a static strap to ensure that any accumulated electrostatic charge is discharged from your body to the ground.
Page 5
For product-specific information, see the Service and Technical Reference Guide for your HP workstation at http://www.hp.com/support/workstation_manuals. Step 2—Installing rails and flanges Align the left bracket with the screw holes on the left side (the bottom) of the chassis (1). Use a Torx driver and two screws to attach the flange (2). Align the inner slide with the two screw holes on the left side (the bottom) of the chassis (3).
Page 6
Insert the slide adjustment attachment (3). NOTE: This step applies to adjusting slides for shallower or deeper non-HP racks. Figure 3 Adjusting slides Sliding rack mount kit installation ENWW...
Page 7
Installing on round hole and square hole racks These instructions apply to racks such as standard HP racks. NOTE: This product must be mounted in the middle of a 4U space. Use the Mounting Aid at the end of this document to determine a 4U space and mark the center. Engage the three pins on the rear slide mounting bracket in the holes in the rear rack column, and slide forward to lock in place (1).
Page 8
Installing on threaded hole racks NOTE: This product must be mounted in the middle of a 4U space. Use the template in Mounting Aid in this document to determine a 4U space and mark the center. Remove the three pins from the rear slide mounting bracket using a flat blade screwdriver (1). Remove the three pins and two nuts from the front slide mounting bracket (2).
Page 9
Installing on earlier HP racks NOTE: The parts for this procedure are available separately in adapter kit number 5064-9677. Remove the rear mounting brackets from the outer slides (1). Remove the front mounting brackets from the outer slides (2). Save the nuts for use in steps 5 and 6 below.
Page 10
Step 4—Mounting into a rack Insert the inner rails into the outer rails. Push the workstation to slide it completely into the rack. You might need to release the latches on the slides. Secure the workstation into the rack by tightening the thumb screws on the mounting flanges. NOTE: Two people are necessary to properly align and install the workstation and rails.
Page 11
Mark the center at 2U. This will be the center line of the slides. Figure 9 Mounting aid Step 5—Reassembling the workstation When installation is complete, replace the access cover (if necessary), restore power, and power up the workstation. ENWW Step 5—Reassembling the workstation...