Page 1
Hitachi Gigabit Router GR2000 Series Enhanced Version Routing Software 06-02 (OS3) Installation Guide S-9181-31X...
Page 2
Routing Software 06-02 (OS3) Installation Guide Statement on EN55022 Compliance WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Statement on Federal Communications Commission (FCC) Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Page 3
Trademarks Ethernet is a product name of Xerox Corp., USA. Ethernet is a trademark of Fuji Xerox Co., Ltd. MS-DOS® is a registered trademark of Microsoft, Corp. UNIX is a registered trademark, in the USA and other countries, licensed by X/Open Company Limited.
Routing Software 06-02 (OS3) Installation Guide Change Record Revision No. Date 03-00/D January 19, 2001 04-00/B February 19, 2001 05-00/A May 18, 2001 05-01/A OS3 July 31, 2001 06-00 OS3 August 8, 2001 06-02 OS3 October 31, 2001 Preface This description explains methods used to install this version of the routing software in a new MC and to update the routing software from an old version to this version.
Page 5
Abbreviations ANSI BECN BGP4 BPDU CATV CIDR CLLM CLNP CSMA/CD DHCP DLCI DSAP DVMRP ELAN S-9181-31X ATM Adaptation Layer Available Bit Rate Authority and Format Indicator Alarm Indication Signal American National Standards Institute Address Resolution Protocol Autonomous System Asynchronous Transfer Mode Backward Explicit Congestion Notification Border Gateway Protocol Border Gateway Protocol 4...
Page 6
Routing Software 06-02 (OS3) Installation Guide Echo Response Echo Request End System Frame Check Sequence Filtering Data Base FDDI Fiber Distributed Data Interface FERF Far End Receive Failure HDLC High-level Data Link Control Hitachi Network Architecture ICMP Internet Control Message Protocol Initial Domain Identifier IEEE Institute of Electrical and Electronics Engineers, Inc.
Page 7
NSAP NetBIOS NSAP OC-3c OC-12c OSPF PIM-DM S-9181-31X Multi Mode Fiber Maximum Receive Unit Network Service Access Point Maximum Transfer Unit Name Binding Protocol Network Control Protocol Network Entity Title Network Basic Input/Output System Network Interface board Non-Return-to-Zero Network Service Access Point Optical Carrier level 3 concatenation Optical Carrier level 12 concatenation Operation Administration and Management...
Page 8
Routing Software 06-02 (OS3) Installation Guide Start Delimiter Synchronous Digital Hierarchy SDLC Service Advertising Protocol SD-I Super Digital I interface Start Frame Delimiter Single Mode Fiber Systems Networking Architecture SNAP Sub-Network Access Protocol SNMP Simple Network Management Protocol SONET Synchronous Optical Network Shortest Path First Spanning Tree Sequenced Packet Exchange...
/usr/var/core/* to delete the file and secure a capacity of free space in the MC, and then perform update. 9. Once you log in to a GR2000 from a management terminal with a telnet or rlogin and execute a ppupdate command, do not break the telnet or rlogin connection...
Routing Software 06-02 (OS3) Installation Guide automatic restart. If the connection is broken, the ppupdate command does not terminate to fail in updating, and restoration of the GR2000 may be disabled. 10. If a message " ppupdate command, follow the instructions below: Transfer the update file again to the user’s home directory, then execute...
Page 13
When the target of the update is S-9181-31X (ROUTE-OS3-X), Table 2-4 shows the available update versions, available MC capacity, and execution of the updating boot ROM on the CPU board. Note tha t 1K is equal to 1024 bytes. Table 2-4 Free MC Space Required for Updating Earlier Version 04-00-/B...
Routing Software 06-02 (OS3) Installation Guide Update Procedure 1 This is an update procedure for a GR2000 that is configured from one RM using two MCs. It updates the backup and current MCs, both with an old version of software stored in them.
Upon restart, communication is interrupted temporarily. Do not pull out and insert an MC card while updating the software. 1. Log into a GR2000 with a user ID that the user has set (for example, 2. Enter an admin command. The command prompt changes to 3.
Page 16
Upon restart, communication is interrupted temporarily. Do not pull out and insert an MC card while updating the software. 1. Log into a GR2000 with a user ID that the user has set (for example, operator). 2. Enter an admin command. The command prompt changes to 3.
Page 17
RMs of the active and standby systems. After the updating procedure for the current MC in the RM of the active system is complete, the GR2000 automatically restarts up. Note that when it restarts up, communication is interrupted temporarily.
Files used for Installation Directory in CD-ROM 1. Log into a GR2000 with an account that the user has set (for example, 2. Execute a admin command to switch to the 3. Insert an MC to be updated into a backup slot.