DOC. No. 1SDH002289A1002 - Rev. 1.0
Lite Panel Pro
User Manual

Advertisement

loading

Summary of Contents for ABB Lite Panel Pro

  • Page 1 DOC. No. 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro User Manual...
  • Page 3 6 - Diagnostics and maintenance 6.1 - Updating the software 6.2 - Troubleshooting & FAQ 6.3 - Device reset 6.4 - Replacement of the battery 6.5 - Disposal iii | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro...
  • Page 4 | © 2023ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro...
  • Page 5 WARNING! indicates a hazardous situation which, if not avoided, could result in death or serious injury. 5 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 1 - Introduction | 1.1 - Introduction to this manual...
  • Page 6 Keep this document in an accessible place for consultation when required. Lite Panel Pro must be used by qualified personnel who have read all installation instructions. Follow the safety procedures indicated by your company and make sure to make devices safe according to regulations.
  • Page 7 Lite Panel Pro and the control system is not totally secure. To protect Lite Panel Pro and make sure that it functions as expected, connect Lite Panel Pro to a reliable network, that is, strictly limited and monitorable. In addition, access to Lite Panel Pro must be limited to persons authorized to make changes to the configuration.
  • Page 8 ABB | Lite Panel Pro BSMI (Taiwan) RCM (Australia & New Zealand) Anatel (Brazil) For further information, please refer to https://www.edimax.com/edimax/merchandise/merchandise_ detail/data/edimax/global/wireless_adapters_ac1200_dual-band/ew-7822ulc/. 8 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 1 - Introduction | 1.2 - Safety information...
  • Page 9 RS485 COM port) maximum 20 that communicate via Ethernet network (Modbus TCP/IP protocol - ETH 1 port) NOTICE : Lite Panel Pro and Modbus TCP devices must be connected to the same private network as the customer. Supported ABB devices Lite Panel Pro Supports various ABB low-voltage devices.
  • Page 10 The list of variables that can be monitored for each supported device is available at the following link: https://search.abb.com/library/Download.aspx?DocumentID=1SDH002323A1001&LanguageCode= en&DocumentPartId=&Action=Launch Supported third-party Lite Panel Pro also supports third-party devices. At the following link you can find a list of available templates and the corresponding Modbus map exposed by Lite Panel Pro: devices https://search.abb.com/library/Download.aspx?DocumentID=1SDH002322A1001&LanguageCode= en&DocumentPartId=&Action=Launch...
  • Page 11 Description Power supply area Connections area LED and pushbuttons area Power supply area 11 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 2 - Lite Panel Pro | 2.2 - Structure of Lite Panel Pro...
  • Page 12 RS485. This type of port supports the Half Duplex transmission system. Note : the Lite Panel Pro package does not include the adapter to connect the COM1/COM2 ports of Lite Panel Pro to the serial bus to which the Modbus RTU devices are connected.
  • Page 13 Description Reset button for forced and immediate restart of the device. Data saved in the Lite Panel Pro will not be lost. Fore more information on reset, see Device reset. Overheating or low battery LED. The LED states are listed below: Flashing red: Battery voltage is below 2.5V.
  • Page 14 Make sure that the system is properly (ergonomically) accessible to the operator. Choose a suitable mounting height Lite Panel Pro may only be used by personnel qualified for the specific task and in accordance with the instructions in this manual.
  • Page 15 Copper conductor, certified to operate at least at 75°C. NOTICE : *the Lite Panel Pro front panel provides IP65 protection if the following conditions are met: installation panel thickness of 2 to 6 mm maximum limit of deformation on the plane of the installation panel equal to 0.5 mm permissible surface roughness on the installation panel in the gasket adhesion area ≤...
  • Page 16 The administrator is the person responsible for Lite Panel Pro. The administrator is responsible for ensuring that all persons who connect to Lite Panel Pro are authorised to do so. Only the administrator has the permissions to enable or disable other users and can change the passwords of all users. The administrator is advised to change all default passwords (see User management) after the first login.
  • Page 17 Shows the current page and the total number of pages. Buttons allow you to navigate between pages. 17 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 2 - Lite Panel Pro | 2.5 - Main page...
  • Page 18 Monitor the scanned devices. See Monitoring a device. Login When Lite Panel Pro is switched on or restarted, the main page is shown. Click on the login button at the top right and log in by selecting the desired user.
  • Page 19 8. Set the communication parameters for RS485 ports COM1 and COM2 dedicated to Modbus RTU communication. 19 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 2 - Lite Panel Pro | 2.6 - First steps...
  • Page 20 11. Click on Start Scan: the devices found appear. Note : Lite Panel Pro it will only search the selected network for supported ABB devices (see Introduction to Lite Panel Pro ). To manually add third-party devices or devices not included in the...
  • Page 21 12. Select the desired devices to be monitored. Click on Add devices and then Finish: a summary screen appears. 13. Click on Finish to complete the commissioning procedure. 21 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 2 - Lite Panel Pro | 2.6 - First steps...
  • Page 22 ABB | Lite Panel Pro 3 - Settings The following chapters describe the setting pages for Lite Panel Pro. Note : access to some areas and the way they are displayed may be different depending on the user profile User management selected (see 3.1 - Page System...
  • Page 23 Panel Pro (see Updating the software). HTTPS Allows you to upload the .pxf file containing the HTTPS certificate. 23 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 3 - Settings | 3.1 - Page System...
  • Page 24 COM1 Configure serial port COM1 for Modbus RTU communication COM2 Configure serial port COM2 for Modbus RTU communication 24 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 3 - Settings | 3.2 - Page Connectivity...
  • Page 25 Change the password of a user Reset a user’s password to the default setting. What it looks like 25 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 3 - Settings | 3.3 - Page Users...
  • Page 26 Enter the slave addresses or range to be scanned. 3. Click on Start scan: Lite Panel Pro Search the selected network for devices among the supported ABB devices (see Introduction to Lite Panel Pro) and those found will be displayed.
  • Page 27 27 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 3 - Settings | 3.4 - Page Devices...
  • Page 28 4. For each variable monitored, set the Modbus configuration parameters (see Page Device models). 5. Click on Add model. 28 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 3 - Settings | 3.5 - Page Device models...
  • Page 29 Property, if the variable does not change often or is fixed Variable, if it changes frequently type of Byte order 29 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 3 - Settings | 3.5 - Page Device models...
  • Page 30 4.1 - Page Overview 4.2 - Page Monitoring 4.3 - Page Alarms and warnings 4.4 - Page Network analyser 4.5 - Page Diagnostics 30 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 4 - Monitoring a device |...
  • Page 31 : the device can also be added to favourites from the Monitoring, Alarms and Warnings, Network Analyser and Diagnostics pages. 31 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 4 - Monitoring a device | 4.1 - Page Overview...
  • Page 32 Variable Logging Voltages, currents, powers Average value in the interval Energy Actual consumption in the interval 32 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 4 - Monitoring a device | 4.2 - Page Monitoring...
  • Page 33 2. To view the alarm history, click on Trends. From the side filter, select the desired interval (last hour, last day, current week, current month, current year, all or a customised period). 33 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 4 - Monitoring a device | 4.3 - Page Alarms and warnings...
  • Page 34 Show monitoring of power quality in terms of harmonics, micro-breaks or voltage dips. What it looks like Part Description Harmonics Device harmonics graph Statistics Network analyser statistics 34 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 4 - Monitoring a device | 4.4 - Page Network analyser...
  • Page 35 Note : the last 200 device events are displayed. 35 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 4 - Monitoring a device | 4.5 - Page Diagnostics...
  • Page 36 For each command selected, a screen appears to confirm the execution of the command. 36 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 5 - Other functions | 5.1 - Remote control of the device...
  • Page 37 : even when disabled, alarms and warnings are logged in the relevant section. 37 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 5 - Other functions | 5.2 - Real-time display of warnings and alarms...
  • Page 38 You can also access the Lite Panel Pro from your own computer and use all its functionalities without having to use the device directly. In fact, Lite Panel Pro it exposes a web server to your IP address. Accessing Lite Panel Pro from To access Lite Panel Pro from a computer, you must connect your computer to the same local network as Lite Panel Pro and insert the web address of Lite Panel Pro in any web browser .
  • Page 39 2. To load the image of the electrical installation, click on Choose file, select the desired image and then click on Upload image. 3. To edit the image and add the devices monitored by Lite Panel Pro, click on Edit diagram. Note...
  • Page 40 Click on Exit edit 7. To view information about a device, click on the tag associated with that device. 40 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 5 - Other functions | 5.4 - Diagram function...
  • Page 41 ABB | Lite Panel Pro 5.5 - Report generation >> main page > Reports Lite Panel Pro allows customisable reports to be generated to track historical measurement trends. Introduction List of parameters for The parameters for configuring a report are listed below:...
  • Page 42 Managing third-party devices For details and procedures regrading this feature, see Page Device models. 42 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 5 - Other functions | 5.6 - Management of third-party devices...
  • Page 43 Panel Pro, using the Modbus TCP connection to the panel. Operation 1. Modbus TCP requests sent to Lite Panel Pro with slave address greater than 1 are forwarded to the respective Modbus RTU devices connected to the panel. 2. Lite Panel Pro receives the response from the queried device and forwards it via Modbus TCP to the external device.
  • Page 44 5.8 - Epic Mobile App Introduction Epic Mobile app allows you to access the Lite Panel Pro interface directly from your smartphone and download reports generated by the device. Associate Epic Mobile with 1. Connect the Wi-Fi dongle to Lite Panel Pro.
  • Page 45 Send an email to the Support Centre (global-el.operations.digital@abb.com). The Support Centre will provide help and guide you through the software update. 6.2 - Troubleshooting & FAQ An updated table of the problems most frequently encountered when using Lite Panel Pro and possible solutions can be found at the following link. https://search.abb.com/library/Download.aspx?DocumentID=1SDH002325A1001&LanguageCode= en&DocumentPartId=&Action=Launch...
  • Page 46 Perform a hard reset NOTICE : with this procedure, data saved in Lite Panel Pro will be lost and will no longer be recoverable. 1. In Settings > System > Main settings, click on Shutdown: Lite Panel Pro switches off.
  • Page 47 ABB | Lite Panel Pro 6. Move to the Exit page, click on Exit Saving Changes and then on Yes: Lite Panel Pro it will restart. Note : the procedure takes a few minutes. 47 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0...
  • Page 48 : if the battery is low, the device time may not be reliable and may have a negative impact on data logging. Inside Lite Panel Pro there is a buffer battery that needs to be replaced when its LED flashes red, see Structure of Lite Panel Pro.
  • Page 49 For more detailed information concerning disposal, please contact the relevant government agency, waste disposal service or the supplier from whom you purchased the product. 49 | © 2023 ABB | 1SDH002289A1002 - Rev. 1.0 Lite Panel Pro - 6 - Diagnostics and maintenance | 6.5 - Disposal...
  • Page 50 Copyright © 2023 ABB S.p.A. All rights reserved...