Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
The use of symbols in this document is to attract your attention to possible danger. The symbols and warnings themselves do not eliminate any danger, nor are they substitutes for correct
accident prevention measures.
1.
SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
FWARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.
A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected
by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it
to the power supply. See 1.1.1. and 1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK
3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation
extends beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol
To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10. This product is supplied without a plug fitted. To fit a plug, follow the instructions detailed in paragraph 1.1.9.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of
2.5mm
section cable. If extension reel is to be used outdoors, ensure it is marked for outdoor use.
2
1.2.
GENERAL SAFETY INSTRUCTIONS
Familiarise yourself with the application and limitations of the panel dryer.
!
Ensure the panel dryer is in good order and condition before use. If in any doubt do not use the unit and contact an electrician.
!
Only use recommended attachments and parts. To use non-recommended items may be dangerous and will invalidate your warranty.
!
Use the panel dryer with post in the vertical position only and ensure it is placed on a firm, level floor.
!
Check that lamp guards are in place, undamaged and firmly attached.
!
Keep tools and other items away from the panel dryer when it is in use.
!
Keep the work area clean and clear of unnecessary items.
!
Keep children and unauthorised persons away from the working area.
!
Remember that the lamp panels will get hot, allow to cool after use.
!
DO NOT dis-assemble the panel dryer for any reason. The panel dryer must be checked by qualified personnel only.
%
DO NOT use the panel dryer outdoors, or in damp, or wet locations, and DO NOT operate within the vicinity of flammable liquids, gases or solids.
%
DO NOT use this product to perform a task for which it has not been designed.
%
F WARNING! If a fuse blows, ensure it is replaced with an identical fuse type and rating.
When not in use, store the panel dryer carefully in a safe, dry, childproof location.
!
INSTRUCTIONS FOR:
INFRA-RED PANEL DRYER
ML2250
MODEL:
Blue
Neutral
Wire
FUSE RATING 13 AMP
, are fitted with live (brown) and neutral (blue) wires only.
, but to be absolutely sure that the
2
Yellow & Green
Earth Wire
Brown
Live
Wire
Cable
Restraint