Variable
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection according to EN 60 529
Cable connection
Maximum tightening torque of the fixing screws
9.1.7
SIWAREX WL260 SP-S SC
Table 9-7
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
Combined error F
Deviation F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
SIWAREX WL200
Operating Instructions, 07/2024, A5E02199611B-14
is
tn
tu
ts
Technical data SIWAREX WL260 SP-S SC
max
LC
min
comb
V
cr
Kc
Ko
min
u
d
lq
Value
≥ 5000 MΩ at 50 V DC
- 10 to + 40 °C
- 35 to + 65 °C
- 35 to + 65 °C
Stainless steel, mat. no. 1.4542
IP68
Six-core, shielded PU cable
6 m
10 Nm
Single-point load cell
Single-point scales, conveyor scales
10, 20, 50, 100, 200, 300, 400,
500 kg
C3
3000
E
/ 10000
1)
max
≤ ± 0.02% C
n
± 0.02% C
n
≤ ± 0.0245%
≤ ± 0.0100%
≤ ± 0.0140%
0 kg
150% E
max
300% E
max
100% E
max
Technical data
9.1 Functional data
Value
WL260
SP-S SC
10, 20, 50 kg
C4
4000
E
/ 40000
max
≤ ± 0.014% Cn
≤ ± 0.0184%
≤ ± 0.0080%
≤ ± 0.0035%
0 kg
150% E
max
300% E
max
100% E
max
57