hit counter script
Honeywell F90A1050 Manual
Honeywell F90A1050 Manual

Honeywell F90A1050 Manual

Self-contained commercial electronic air cleaner

Advertisement

Quick Links

This Owner's Manual is provided and hosted by Appliance Factory Parts.
HONEYWELL F90A1050
Owner's Manual
Shop genuine replacement parts for HONEYWELL
F90A1050
Find Your HONEYWELL Air Cleaner Parts - Select From 215 Models
-------- Manual continues below --------

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F90A1050

  • Page 1 This Owner's Manual is provided and hosted by Appliance Factory Parts. HONEYWELL F90A1050 Owner's Manual Shop genuine replacement parts for HONEYWELL F90A1050 Find Your HONEYWELL Air Cleaner Parts - Select From 215 Models -------- Manual continues below --------...
  • Page 2: Table Of Contents

    Electrical Troubleshooting ..........16 Replacement Parts List/Exploded View ......22 Limited One-Year Warranty ..........24 The Honeywell Trademark is used under license from Honeywell Intellectual Properties, Inc. by Air-Pure Systems. Honeywell International Inc. makes no representations or 68-0103-6 Revised 11-07...
  • Page 3: Specifications

    ORDERING INFORMATION If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: Your local Honeywell Commercial Air Products Distributor. Air-Pure Systems 16873 Fish Point Rd. SE Prior Lake, MN 55372-1714...
  • Page 4: Planning The Installation

    F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER Shipping and Installation Weight: 19-1/4 (489) 14-1/2 (386) o l i l a i l l e LATCHES (610) l l a (406) 29-1/4 POWER (743) CORD Dimensions: See Figs. 1 and 2. 3 (76) Approvals: Underwriters Laboratories Inc.
  • Page 5 If any questions should arise, consult your full-service FAN DRAWS CONTAMINATED AIR INTO distributor Honeywell Commercial Air Products. THE BOTTOM OF THE F90. To calculate the number of F90s needed using occupant load, refer to Example 2 (page 6).
  • Page 6 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER M923 Fig. 5. F90 Coanda air flow pattern. Outdoor Air ASHRAE Standard 62-89 specifies that every commercial DANCE FLOOR space be provided with fifteen cfm per occupant of outdoor air to replenish oxygen and dilute CO2. If other internal STAGE sources of gaseous contamination are present, additional outside air is needed to dilute the contamination.
  • Page 7: Installation

    4. After installation is complete, check out product prefilter to avoid cuts from the sharp metal edges, operation as provided in these instructions. collection plates, and ionizer wires. WARNING Must be installed by only a Honeywell trained installer. 68-0103-6 Revised 11-07...
  • Page 8 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER CAUTION IMPORTANT When mounting near walls, allow at least 16 in. (406 Do not connect the power supply until F90 is mm) for cell installation and removal and 15 in. (381 mounted. If the F90 is powered before an electrical mm) for cover installation and removal.
  • Page 9 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER 1. LOCATE WASH LED CUTOUT BEHIND 2. USE A KNIFE TO CUT A HOLE IN SWITCH COVER ASSEMBLY STICKER. THE STICKER. INSERT LED INTO LENS FROM BACK 3. PUSH LED LENS INTO PLACE. OF THE SWITCH COVER ASSEMBLY. 5.
  • Page 10 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER F90A F90B 19-1/4 (489) 29-1/4 (743) 24 (610) 14-1/2 (368) 7/8 (22) DIAMETER KNOCKOUT 16 (406) (102) LATCHES 29-1/4 (743) (610) (610) 16 (406) 29-1/4 (406) POWER (743) CORD 2 (51) 3 (76) 3-1/4 (83) (203) 9 (229)
  • Page 11 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER 2 x 4 INCH (51 x 102 mm) SELF-CLINCHING OR EQUIVALENT PEM STUD: CROSS PIECE TO NUT AND WASHER TOP AND BOTTOM SUPPORT AIR CLEANER 1-1/2 INCHES (38 mm) 1/16 INCH (2 mm) 7/8 INCH (22 mm) 1⁄4 INCH (6 mm) DIAMETER...
  • Page 12 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER BOLT AND Permanent Wiring WASHER WALL BRACKET 1. Loosen the two screws and remove the plate covering the wiring compartment. 2. Remove the power cord. • Cut the black and white wires of the power cord, MOUNT AS CLOSE leaving six inches from the electrical connector.
  • Page 13: Checkout

    F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER Installing Cover Check F90 Operation 1. Before installing, study the inside of the F90 cover. One end has two latches and the other has two hinge Turn on power. pins. To properly install the cover, connect the hinge Push the test button to assure the power supply is pins to the hinges.
  • Page 14 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER Cleaning the F90 Cleaning the Cell Using Alkaline Base Detergent The F90 removes a variety of contaminants from the air. As it cleans the air, the F90 cells and prefilters become dirty, WARNING lowering the cleaning efficiency. To maintain the F90 reliability and efficiency, regularly clean, inspect, and service Hazardous Chemical.
  • Page 15 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER 9. Carefully wipe ionizer wires to remove any remaining a n i g n i residue. 10. Check the collection plates of the cell for any detergent i n A r i a s i D g r e t n e t u l...
  • Page 16 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER HIGH VELOCITY DETERGENT SPRAY STEAM M1541 Fig. 16. Reinstalling F90 cells. REPLACING AN IONIZER WIRE. M677B Fig. 15. Using high velocity water or steam to clean cells. 6. Slide the cells into the channel guides until they touch the backstop of the F90.
  • Page 17: Electrical Troubleshooting

    F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER If desired, the ozone generated by the F90 can be reduced in one of two ways: • Install the optional activated carbon filters. Tools And Equipment • Open the cover and move the F90 performance switch to the LO setting.
  • Page 18 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER START WARNING RISK OF ELECTRIC SHOCK THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO REDUCE RISK OF ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING OTHER THAN CONTAINED IN THE OPERATING MAKE SURE CELLS INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
  • Page 19 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER ELECTRONIC AIR CLEANER POWER BOX SECURING SCREWS (5) POWER BOX POWER BOX COVER POWER BOX COVER SECURING SCREWS (5) NOTE: SCREWS ONLY NEED TO BE LOOSENED, NOT REMOVED. M2422A Fig. 21. Removing the F90 Power Box Assembly. 68-0103-6 Revised 11-07...
  • Page 20 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER BLACK COLLECTOR TEST RED IONIZER BUTTON POWER SUPPLY CONTACT BOARD PERFORMANCE BLACK SWITCH BLACK CHECK (RED) BLACK WASH (YELLOW) (YELLOW) ON-OFF/3-SPEED FAN SWITCH WIRING TERMINALS PUSH BUTTONS BROWN VIOLET BLUE 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
  • Page 21 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER BLACK COLLECTOR TEST RED IONIZER BUTTON POWER SUPPLY CONTACT BOARD PERFORMANCE BLACK SWITCH (YELLOW) WASH (YELLOW) CHECK (RED) ORANGE BLACK WHITE LAMP WHITE BROWN WHITE TERMINAL BOARD FOR POWER SUPPLY CONNECTIONS. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
  • Page 22 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER BLACK COLLECTOR TEST RED IONIZER BUTTON POWER SUPPLY CONTACT BOARD PERFORMANCE BLACK SWITCH BLACK CHECK (RED) BLACK WASH (YELLOW) (YELLOW) ON-OFF/3-SPEED FAN SWITCH PUSH BUTTONS WIRING TERMINALS BROWN VIOLET SPEED CONTROL BLUE MODULE 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
  • Page 23: Replacement Parts List/Exploded View

    F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER REPLACEMENT PARTS LIST/EXPLODED VIEW See Fig. 26 for exploded view. l l i l l i t l i t l i t l i i t i l l i Parts and Optional Accessories Not Illustrated e l l l l a n i l...
  • Page 24 F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER M11675 Fig. 26. F90A exploded view. Part numbers are keyed to Parts List. 68-0103-6 Revised 11-07...
  • Page 25: Limited One-Year Warranty

    F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER LIMITED ONE-YEAR WARRANTY Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use and service, for a period of one (1) year from the date of purchase by the originial end-user. If at anytime during the warranty period the product is defective or malfunctions, Air-Pure Systems, through the distributor or dealer, from which the product was purchased, or through an authorized warranty repair station, shall at Air-Pure Systems option, replace or repair the defective product or component.

This manual is also suitable for:

F90aF90b

Table of Contents