Page 21
USER MANUAL Inverter Compressor 2 in 1 RAD-DIA17HK Warning notices: Before using this product, please read this manual carefully and keep it for future reference.
Page 22
Directory SAFETY PRECAUTIONS............3 GET TO KNOW YOUR PRODUCT.........6 Identi cation of parts Positioning the unit Accessories GET TO KNOW THE FEATURES...........9 Control Panel DUMP THE COLLECTED WATER........12 Bucket drainage Continuous drainage CARE AND MAINTENANCE..........14 Clean the Grill and Case Clean the bucket Clean the air filter SPECIFICATIONS AND PURIFICATION DATA....17 Speci cations...
SAFETY PRECAUTIONS Must read the warning message. Read Safety Precautions Before Operation and Installation To prevent death or injury to the user or other people and property damage,the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage. Explanation of Symbols The signal word indicates a hazard with a medium level of risk which, WARNING...
Page 24
CAUTION • This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Page 25
CAUTION • The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data speci c to this unit. • Be sure the unit is properly grounded. To minimize shock and re hazards, proper grounding is important.
GET TO KNOW YOUR PRODUCT Name of each component of the product Identi cation of parts NOTE All the illustrations in the manual are for explanation purpose only. Your machine may be slightly diferent. Product overview Front View Back View control panel rear grille hook for power cord...
Positioning the unit Safe distance requirements 40cm or more 20cm or more 20cm 20cm or more or more 40cm or more Front View Top View Casters(At four points on the bottom of unit) • Casters can move freely. • Do not force casters to move over carpet, nor move the unit with water in the bucket. (The unit may tip over and spill water.) A dehumidi er operating in a basement will have little or no efect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.
When using your product Preparations for product use. • This unit is designed to operate with a working environment between 5°C/41°F and 32°C/90°F,and between 30%(RH) and 80%(RH). • If the unit has been switched of and needs to be switched on again quickly , allow approximately three minutes for the correct operation to resume.
GET TO KNOW THE FEATURES Operation Display Control Panel NOTE The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly diferent according to the models. When the machine is turned on or of, or when the mode is switched on, there will be a slightly obvious sound of compressor operation, because the compressor frequency is increased or decreased, it is normal.
Page 30
• The selected time will register in 5 seconds, and NOTE the system will automatically revert back to display the previous humidity setting or room When this function is selected, FAN speed humidity when the unit is on. When the unit is of, regulation is not available.
Page 31
More features Display Wireless operation(on some models): Shows Error codes and protection code: The unit • For the rst time to use Wi function, press the may stop operation or continue to run safely. If the POWER button for 3 seconds to initiate the Wi error codes appear, wait for about 10 minutes.
DUMP THE COLLECTED WATER When your product has been in use for a while. There are two ways to remove collected water. Type 1: Type 2: Bucket drainage Continuous drainage Note: The drainage hose is optional (Inner diameter) φ 13.5mm) (Outer diameter) φ...
Continuous drainage NOTE · Make sure the hose is secure so there are no leaks. · Place the end of the hose into the drain outlet and make sure the end of the hose is level or downwards to let the water ow smoothly . Remove the rubber plug.
CARE AND MAINTENANCE How to clean & maintenance your product. Turn o the dehumidi er of and disconnect the plug from the power source before cleaning. Clean the Grill and Case · Use water and a mild detergent. Do not use bleach or abrasives. ·...
Page 35
To remove: · Press down the tab on the lter and pull it outward, then take it out. · Clean the lter with warm, soapy water. Rinse and let the lter dry before replacing it. Do not clean the lter in a dishwasher.
Page 36
When not using the unit for long time periods Step 2 Step 1 Step 3 After *Please refer to the actual plug, and the legend is for reference only. Step6 Step 4 Step 5 · Step 1: Unplug the product, after turning of the unit. ·...
SPECIFICATIONS AND PURIFICATION DATA Speci cations Model RAD-DIA17HK Color White Product Dimensions(W*D*H)(mm) 420*265*662 MEELS Standard – 17L/Day (26.7℃ 60%) Dehumidifying Capacity Manufactory’s Standard – 28L/Day (30℃ 80%) Power AC 220V/50Hz 13A/250V Plug Type Puri cation data ITEM Puri cation Test laboratory Intertek Testing Services Shenzhen Ltd.
TROUBLESHOOTING Before calling for service, review the situation below rst yourself. Problem What to check Make sure the dehumidifiers plug is pushed completely into the outlet. Check the house fuse/circuit breaker box. Unit does not start Dehumidifier has reached its preset level or bucket is full. Water bucket is not in the proper position.