Honeywell C6097A Operating Instructions Manual
Honeywell C6097A Operating Instructions Manual

Honeywell C6097A Operating Instructions Manual

Gas pressure switches
Hide thumbs Also See for C6097A:

Advertisement

Quick Links

Gas pressure switches C6097A, C6097B
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Checking the usage . . . . . . . . . . . . . . . . . . . . . 2
3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
6 Tightness test. . . . . . . . . . . . . . . . . . . . . . . . . . 3
7 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
8 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
9 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 6
10 Designed lifetime . . . . . . . . . . . . . . . . . . . . . . 6
11 Certification . . . . . . . . . . . . . . . . . . . . . . . . . . 6
12 Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
13 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
oPeRAtInG InstRUCtIons
Cert. Version 02.20 · Edition 01.24 · EN · 03251518

1 sAFetY

1.1 Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the operator.
This unit must be installed and commissioned in
accordance with the regulations and standards in
force. These instructions can also be found at www.
docuthek.com.
1.2 explanation of symbols
1  , 2  , 3  , a  , b  , c  = Action
➔ = Instruction
1.3 Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
1.4 safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DAnGeR
Indicates potentially fatal situations.
WARnInG
Indicates possible danger to life and limb.
CAUtIon
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
1.5 Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell C6097A

  • Page 1: Table Of Contents

    Gas pressure switches C6097A, C6097B oPeRAtInG InstRUCtIons Cert. Version 02.20 · Edition 01.24 · EN · 03251518 1 sAFetY 1.1 Please read and keep in a safe place Please read through these instructions carefully before installing or operating. Following the installation, pass the instructions on to the operator.
  • Page 2: Checking The Usage

    C6097A: switches with falling pressure, – When installing outdoors, place the C6097 in a C6097B: switches with rising pressure. roofed area and protect from direct sunlight negative (even IP 65 version).
  • Page 3: Wiring

    4 WIRInG CAUtIon – To ensure that the C6097 is not damaged 1 cm = 1 mbar during operation, note the switching capacity, (0.4" = 0.4"WC) see page 6 (9 Technical data). 7 Apply pressure. In doing so, monitor the In the case of low switching capacities, such as switching point on the ohmmeter and the 24 V, 8 mA, for example, we recommend using an...
  • Page 4: Maintenance

    8.3 Restrictor orifice 7 MAIntenAnCe In order to ensure smooth operation, check the tightness and function of the pressure switch every year, or every six months if operated with biogas. ➔ A function check can be carried out in case of falling pressure monitoring, e.g.
  • Page 5 8.8 Cover for auto reset Order No.: 32003040-003/U. 8.9 Weather protection cover NO 2 In the case of outdoor installation, the weather pro- tection cover provides permanent protection against condensation and weathering of housing parts. The weather protection cover is made of 1 mm (0.04") thick stainless steel.
  • Page 6: Technical Data

    9 teCHnICAL DAtA 10 DesIGneD LIFetIMe Gas type: natural gas, town gas, LPG (gaseous), This information on the designed lifetime is based flue gas, biogas (max. 0.1 %-by-vol. H S) and air. on using the product in accordance with these Electrical connection: screw terminals. operating instructions.
  • Page 7: Logistics

    11.4 ReACH Regulation The device contains substances of very high con- cern which are listed in the Candidate List of the European REACH Regulation No. 1907/2006. See Reach list HTS at www.docuthek.com. 11.5 China RoHs Directive on the restriction of the use of hazardous substances (RoHS) in China.
  • Page 8 FoR MoRe InFoRMAtIon The Honeywell Thermal Solutions family of products includes Honeywell Combustion Safety, Eclipse, Exothermics, Hauck, Kromschröder and Maxon. To learn more about our products, visit ThermalSolutions.honeywell.com or contact your Honeywell Sales Engineer. Elster GmbH Strotheweg 1, D-49504 Lotte T +49 541 1214-0 hts.lotte@honeywell.com...

This manual is also suitable for:

C6097b

Table of Contents