Page 1
— ABB D RIV ES User’s manual ACS880 democase 1/ 16...
Page 2
U SE R ’ S MAN UAL Related documents You can find manuals on the Internet. See below for the relevant code/link. For more documentation, go to www.abb.com/drives/documents. ACS880-01 manuals 2/ 16...
AC input (supply) connection ..........................12 Degree of protection ..............................12 Ambient conditions ..............................13 Further information ............................. 14 Product and service inquiries ..........................14 Product training ..............................14 Providing feedback on ABB manuals ......................... 14 Document library on the Internet ........................14 3 /16...
U SE R ’ S MAN UAL Safety instructions General safety instructions These safety instructions are intended for all personnel who work on the drive. For complete safety in- structions, see the drive hardware manuals. Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur. If you are not a qualified electrical professional, do not do installation or maintenance work.
U SE R ’ S MAN UAL Delivery content ACS880-01 democase contains: (found in the pocket at the back of the democase) I/O-panel with removable control panel USB to Mini USB –cable for PC-connection Ethernet cable for IO-panel connection 4. Mains cord...
U SE R ’ S MAN UAL Layout Lifting strap IO-panel Control panel USB connection IO-panel connection A Mechanical brake Input voltage switch (115V/230V) Mains switch Fuse terminal Safety input 1 (default: STO) Mains cord connection connection 24V out IO-panel External ZCU External Drive main...
U SE R ’ S MAN UAL Supply switches The demo supply can be controlled with the switches external ZCU supply switch and drive main supply switch. The two switches work separately. The external ZCU supply switch con- trols the external 24V supply to the control unit of the drive and the drive main supply switch controls the 400V main supply to the drive.
U SE R ’ S MAN UAL Basic start-up Put the democase on its back (so that the cover is pointing up) and open the cover. Pull the demo out of the case using the lifting strap and the handle hole (on the lo- wer part of the demo.) WARNING! The demo weighs approximately 18 kg.
U SE R ’ S MAN UAL Default I/O-panel functions (0= LED off, 1 = LED on) AI1: Speed reference AO1: Motor speed AI2: Not in use AO2: Motor current DI1: Stop (0), Start (1) DI2: Forward (0), Reverse (1) DI3: Reset DI4: Ramp selection DI5: Constant speed 1...
U SE R ’ S MAN UAL Safety input connections The safety connections in the demo are made as in the picture below. Safety inputs 2, 3 and 4 are not in use by default. Note that if the IO-cable is not connected, it will automatically result in activation of the STO (safe torque off).
U SE R ’ S MAN UAL Parameters that need to be changed Parameter Name Setting Notes HW configuration 95.01 Supply voltage [2] 380…415 V Correct rating settings made Encoder module settings 91.11 Module 1 type [4] FEN-31 91.12 Module 1 location FEN-31 location in Option slot 3 Encoder 1 configuration 92.01...
Weight: 27 kg / 60 lb Drive type code ACS880-01-02A4-3+K473+L502 (K473 = FENA-11, L502 = FEN-31) Motor details Motor type code: ABB M2VA 63 B 4 (3GVA 062 142-ASC) Motor nameplate: Parameter ACS880-01 parameter Value Motor type 99.03 Motor type Rated current 99.06 Motor nominal current...
U SE R ’ S MAN UAL Ambient conditions The demo is designed for demonstration purposes and for indoor use only. Ambient temperature: Transport: -40 to +70 °C Storage: -40 to +70 °C Operation: -15 to +40 °C, no frost allowed Altitude: 0 to 4,000 m without an effect on demo operation Relative humidity:...
Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to www.abb.com/searchchannels.