Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear goggles Wear protective
instruction
manual
1.
SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all
9
electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products.
Electrical safety information. It is important that the following information is read and understood:
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
9
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
Correct fuse.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is replaced immediately by a
8
qualified electrician.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
1.2.
GENERAL SAFETY
WARNING! Ensure health & safety, government and local authority regulations relating to the transfer of AdBlue® are adhered to when
using this equipment. Familiarise yourself with the pump's applications and limitations, and specific potential hazards peculiar to the
pump.
WARNING! These pumps are designed for use with urea and aqueous media only. DO NOT use for petrol or similar explosive liquids.
▲
DANGER: The electric pump is not protected against explosion and should therefore not be operated in areas where there is a
risk of explosion.
WARNING! Disconnect the pump from the mains or battery power before demounting, servicing or performing any maintenance.
Maintain pump in good condition (use authorised service agent). Drain pump and pipes before dismantling.
9
Maintain correct balance and footing when installing and using the pump. Ensure the floor is not slippery and wear non slip shoes.
9
Ensure the transfer area is free of clutter and has adequate lighting.
9
Ensure that the voltage of the pump matches the voltage of the supply.
9
Keep children and unauthorised persons away from the working area.
9
Replace/repair damaged parts. Use genuine parts. Unauthorised parts are dangerous and will invalidate warranty.
9
DO NOT use the pump without the delivery nozzle attached.
8
DO NOT start or stop the pump by switching on or off at the mains power supply. or disconnecting from battery.
8
DO NOT operate the unit with wet hands. We recommend use of chemical resistant gloves and goggles.
8
DO NOT run the pump dry. If this occurs the pump could be damaged and your warranty will be invalidated.
8
IMPORTANT: It is the installer's responsibility to ensure that all supply pipes, fixtures and fittings are adequate for the safe flow of liquid
urea.
2.
INTRODUCTION
Electric 12V membrane pump specifically designed for the distribution of AdBlue®. Self-priming unit provides a flow rate of up to 34L/min.
Supplied with total of 4m hose, 2m delivery and 2m suction. Manual delivery nozzle and 2m cables with battery clamps. All materials and
seals used on this pump are suitable for use with AdBlue®.
3.
SPECIFICATION
Model no:
TP9912.V2
Current:
18A
Duty cycle:
20min/hr
Flow rate:
34L/min
© Jack Sealey Limited
12V PORTABLE TRANSFER PUMP - ADBLUE®
MODEL NO:
gloves
Power
260W
Speed:
2800rpm
Voltage:
12V
Original Language Version
TP9912.V2 TP99230
Model no:
TP99230
Current:
2A
Duty cycle:
Continuous
Flow rate:
40L/minz
Power
370W
Speed:
2900rpm
Voltage:
230V
TP9912.V2 TP99230 Issue:1 15/01/24