hit counter script
Panasonic AlCare TK-AS500 Operating Instructions Manual
Panasonic AlCare TK-AS500 Operating Instructions Manual

Panasonic AlCare TK-AS500 Operating Instructions Manual

Alkaline ionizer

Advertisement

Quick Links

Thank you for purchasing this Panasonic product.
感謝您購買 Panasonic 的產品。
„ Please read these instructions carefully before using this product, and
save this manual for future use.
„ Please carefully read the "Safety Precautions" (P. EN4–EN8)
of this manual before use.
„ Be sure to check that the purchase date has been entered on the
warranty.
„ Please keep in mind that the manufacturer of the product will not be
responsible for any product malfunctioning or accidents resulting from
the improper installation or operation of the product.
„ 請在使用本產品之前仔細閱讀本說明書, 並妥善保管本說明書以備日後使用。
„ 請在使用之前仔細閱讀「安全注意事項」 (TC4~TC8頁) 。
„ 保證書上的「購買日期」 請務必填寫。
„ 因安裝錯誤或不正確使用, 而造成產品故障或發生事故時, 本公司恕不負責。
Use properly to economize on electricity
Operating Instructions
Alkaline Ionizer
Model No.
正確使用, 節省用電
使用說明書
For Household Use
電解水機
家庭用
TK-AS500
We use NSF42 certified
activated carbon.
我們使用 NSF42 認證的活性碳.
COMPONENT / 成分
Activated carbon (APG-05TGA
60/200) manufactured by
Kuraray Co.,Ltd. used in this
product is Tested and Certified
by NSF International against
NSF/ANSI Standard 42 for
material requirements only.
(Check Date (2023. 6. 4))
本產品使用的活性碳由 Kuraray
Co.,Ltd. 製造的(APG-05TGA
60/200 ) 物料需求由 NSF 國際通
過 NSF/ANSI Standard 42 檢測
和認證。
(檢查日期(2023年6月4日) )

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic AlCare TK-AS500

  • Page 1 電解水機 家庭用 TK-AS500 Model No. We use NSF42 certified Thank you for purchasing this Panasonic product. activated carbon. 感謝您購買 Panasonic 的產品。 我們使用 NSF42 認證的活性碳. „ Please read these instructions carefully before using this product, and save this manual for future use.
  • Page 2 The Alkaline Ionizer z The Alkaline Ionizer produces alkaline ion water and acidic water by electrolysis. z The substances that can be removed with the cartridge are as follows. • Free residual chlorine • Bromoform • 1,2-DCE • Turbidity • Tetrachloroethylene •...
  • Page 3: Table Of Contents

    Contents Safety Precautions Operating Precautions EN10 Part Names and Steps to Take Before Operation Steps to take before operation EN12 EN13 Installation 1 Check the main unit and supplied accessories EN14 Installation 2 Check the shape of faucet EN15 Installation 3 Attach the bypass selector EN18 Installation 4...
  • Page 4: Safety Precautions

    Safety Precautions Please make sure to follow these instructions In order to prevent any harm to human body or damage to property, always follow the instructions below. The following classifies the degree of risks of harm and damage caused by „...
  • Page 5 WARNING In case of abnormality or fault Pay attention to the following precautions z Stop using the product immediately and unplug the z Do not disassemble, repair or remodel power plug. the unit. (Failure to do so can cause smoke, (Doing so can cause a fire and/or electric shock.) fire and/or electric shock.) →...
  • Page 6 Safety Precautions Please make sure to follow these instructions CAUTION Installation location z Do not block the main spout, or bend, twist, flatten, pull or clamp the hose. (Doing so may cause water to leak, interrupt the output of water or cause other problems.) z Do not connect a hose or any other appliances to main spout.
  • Page 7 CAUTION About the application of alkaline ion water and acidic water that cannot be drunk or used z Do not drink the following kinds of water. y Acidic water y Water that comes out of the drain hose y Water that comes out from the main spout while the water quality signal is blinking (Doing so may cause health problems.) z Do not take medicine with alkaline ion water.
  • Page 8 Safety Precautions Please make sure to follow these instructions CAUTION Accidental ingestion Maintenance z Do not leave the supplied z Do not splash water over or wash accessories within reach of the main unit. infants or toddlers. ( Doing so may cause an electric shock or malfunction.) ( Doing so may cause accidental swallowing of accessories.)
  • Page 9: Operating Precautions

    Operating Precautions Water supply Usage z Do not drink water in case of the following z Do not lay down the main unit for use. conditions. (Doing so may cause malfunction.) z Use water with the temperatures shown in Very turbid water, or water containing a great deal of red rust the table below.
  • Page 10: Part Names And Steps To Take Before Operation

    Part Names and Steps to Take Before Operation Main unit Outlet pipe Cover Water supply hose Faucet Power plug Hose strap Main spout Power cord Suction disc Cartridge (P. EN29–EN30) Drain hose Suction cup for fixing the main unit Bypass selector When using alkaline ion water, etc.
  • Page 11 Control panel Display Displays pH Displays the remaining Displays an error of (guideline). amount of water the main unit. (P. EN24) flow until cartridge (P. EN29, EN35) replacement. (P. EN29) Electrode cleaning indicator Water quality signal (Yellow, Green, Pink) (Red) Lights up when the water selected during preparation is ready to be used.
  • Page 12: Steps To Take Before Operation

    Steps to take before operation Check the main Installation 1 unit and supplied P. EN13 accessories Check the shape Installation 2 P. EN14 of faucet Attach the bypass Installation 3 selector P. EN15 – The attaching method P. EN17 differs depending on the shape of faucet.
  • Page 13: Installation 1

    Check the main unit and supplied accessories Installation 1 If any are missing, contact your dealer. Items in the package Main unit Bypass selector „ „ Cartridge Spring Power cord (Consumables) (length: approx. 3 m) Drain hose (With spring / length: approx. 60 cm) Water supply hose (No spring / length: approx.
  • Page 14: Installation 2

    Check the shape of faucet Installation 2 Water faucet to which the Alkaline Ionizer cannot be installed Faucet without a metal lip end Faucet with an end of 10 mm or less 10 mm or less Plastic or other material Shower nozzle Faucet with sensor Note...
  • Page 15: Attach The Bypass Selector

    Attach the bypass selector Installation 3 Keep all parts that are not used during installation, as they may be needed later if the unit is moved or the faucet is changed. Outside-screwed faucet • Water faucet to which the Alkaline Ionizer can be installed without any accessory.
  • Page 16 Attach the bypass selector (continued) Installation 3 Keep all parts that are not used during installation, as they may be needed later if the unit is moved or the faucet is changed. Inside-screwed faucet • Water faucet to which the Alkaline Ionizer can be installed with an accessory.
  • Page 17 Keep all parts that are not used during installation, as they may be needed later if the unit is moved or the faucet is changed. Faucet without an aerator • Water faucet to which the Alkaline  11 mm or more Ionizer can be installed with an 2 13 mm or more, less than 24 mm Bulge...
  • Page 18: Install The Alkaline

    Install the Alkaline Ionizer Installation 4 Choose a stable, level surface. Gasket 9.5 cm or more 17 cm or more Extend the power cord and hose in the manner that best suits the location where the unit is installed. z Do not flatten or bend the cord or hose. When extending the cord and When extending the cord and Bottom of the unit...
  • Page 19: En19

    Secure the drain hose using After completing the preparations, connect the water supply the suction disc. hose. Do not place a garbage bin under the  Remove the hose fastening nut from drain hose. the bypass selector, and pass the hose through the nut.
  • Page 20: Check After

    Check after installation Installation 5 Run alkaline ion water for about 3 to 4 minutes to expel the air inside the main unit. Set the bypass selector to “ ”.  Press Turn on the water faucet to let the water flow. When water is run immediately after installation, the water quality signal blinks approx.
  • Page 21 Reference Check item Trouble inspection location and remedial action page Is there any water leakage Has the bypass selector been installed securely EN15–EN17 from the joint of the bypass on the faucet? selector? → Check again the instructions for “Attach the bypass selector”, and install it securely.
  • Page 22: En22

    Measure and adjust the pH level of water Installation 6 After the Alkaline Ionizer has been installed or after it has not been used for a prolonged period (generally, 1 week or more), be sure to measure the pH level, and check that it is within the “pH standard” before using the Alkaline Ionizer. Remember to measure the pH level periodically (at least once a month).
  • Page 23: En23

    When is adjustment necessary? When the measurement results are beyond the range of “pH level standardˮ, perform adjustment. After the completion of adjustment, measure the pH level again. When the pH level of the Drinking Water No adjustment (Alkaline) 3 or acidic water is within the range required.
  • Page 24: Usage Of Water

    Usage of Water Alkaline ion water Purified Acidic water water Drinking Water Drinking Water Drinking Water (Alkaline) 1 (Alkaline) 2 (Alkaline) 3 Taking Drinking water in daily life medicine Approx. 0.5 to 1 liter a day Non-drinkable Get used to Start of drinking drinking...
  • Page 25 Convenient usage Alkaline ion water Purified Acidic water water Drinking Water Drinking Water Drinking Water (Alkaline) 1 (Alkaline) 2 (Alkaline) 3 Washing Making baby Cooking and the face formula making tea For tea and This mild acidic boiled food water is close For gargling after meal to the acidity of human skin.
  • Page 26: How To Use

    How to Use Water temperature under 35 °C Measure the pH once a month Measure the pH once a month periodically or When is used, water does not when the product is not used for 1 week or more. come out from the drain hose. (P.
  • Page 27 When the water quality signal lights up, When the water quality signal turns „ use water. off while water is flowing When the faucet is not sufficiently opened or PiPiPi the amount of water flow is decreased due to change in water pressure, the water quality signal turns off.
  • Page 28: Maintenance

    Maintenance Important Do not use detergents, cleansers, paint thinners, benzine, alcohol or kerosene for cleaning purposes. If, for instance, a detergent is used by mistake, wipe the surface with a damp cloth immediately to remove all traces of the detergent. ( Otherwise, the detergent may get mixed in with the water running through the Alkaline Ionizer, the plated parts may be damaged or peel off, or the plastic parts may become damaged, discolored or deformed.) y Use of cleansers may also impair the workings of the outlet pipe and cause trouble.
  • Page 29: Replacing The Cartridge

    Replacing the Cartridge Replacement cartridge When the service life of the cartridge is to be expired or the water Model No. : TK-AS500C-EX purifying ability is reduced, please replace the cartridge with a new one. (P. EN42) Cartridge replacement guideline The following shows the 3 replacement guidelines.
  • Page 30 Replacing the Cartridge (continued) Replacing method Do not tip over the main unit, or face up the main spout. (Water may enter the inside of the main unit, resulting in a malfunction.) Since the cartridge usage amount needs to be reset, do not remove the power plug when replacing the cartridge.
  • Page 31: Automatic Electrode Cleaning

    Automatic Electrode Cleaning Automatic electrode cleaning is performed to remove When the calcium deposited on the electrode plate. indicator is lit Wait for a while. Do not remove the power plug. Water coming out of the main spout and drain hose during automatic electrode cleaning cannot be used.
  • Page 32: Changing The Settings

    Changing the Settings How to change Preparation: Please turn off the faucet. At the time of purchase, the product is in the purified water selection mode when water is stopped after use of purified water. Performing the following operation restores the product to the state where Alkaline 1, 2 or 3 is selected even after use of purified water.
  • Page 33: When The Power Or Water Supply Is Cut Off

    When the Power or Water Supply is Cut Off When the power supply is cut off (The breaker has operated, or the power „ plug is removed.) Turn off the faucet if the power is cut off while the Alkaline Ionizer is being used. Purified water comes out during power outage whichever type of water is selected.
  • Page 34: When Moving The Alkaline Ionizer

    When Moving the Alkaline Ionizer Remove water from the main unit with the following steps before moving the product. Stand the main unit while moving. After removing the water, a small amount of water may remain, so put the main unit in a bag, etc. Disconnect the power plug, Put the tip of the water supply hose at and remove the cap.
  • Page 35: Indications And Solutions

    Indications and Solutions Indication Cause and solution Electrolysis is stopped to protect the product. (Purified water is coming out from the main spout.) This may occur depending on the quality of tap water, environment, and usage. → Stop water, wait approx. 3 minutes, and run water again. Electrolysis is stopped to protect the product.
  • Page 36: Q&A

    Q&A Question Answer What is the part number of the TK-AS500C-EX (P. EN42) cartridge for replacement? For usage, we have confirmed a removal capacity of 12 000 liters by Is it possible to use the running water. The cartridge cannot be used beyond the amount. cartridge exceeding (Depending on the water quality, it may not be used even less than 12 000 liters.) the amount of 12 000...
  • Page 37 Question Answer Use it within 1 day at room temperature. How long do the When alkaline ion water is produced, chlorine (sterilizer) in tap water is alkaline ion water removed, making it easier for bacteria to proliferate. and purified water •...
  • Page 38 Q&A (continued) Question Answer It means that the cumulative total time (including cleaning What does a time) that enables electrolysis in the electrolyzer is 850 hours. service life of (equivalent to approx. 7 years with use of 20 minutes a day) 850 hours for the When the electrolyzer is powered-on, the electrode plate in the electrolyzer electrolyzer mean?
  • Page 39: Before Requesting A Repair Service

    Before Requesting a Repair Service First, check P. EN39 to P. EN41. If the problem is not solved after the following contents are checked Disconnect the power plug, and contact the dealer where you purchased the product. Disconnecting the power plug once and inserting it again after approx. 5 seconds may restore the product to the normal state.
  • Page 40 Before Requesting a Repair Service (continued) Problem Check point Faucet and connection parts of bypass selector, water See P. EN21. supply hose, and outlet pipe Bypass selector The cause seems to be calcium, etc. depositing inside the bypass (location other than the selector.
  • Page 41 Problem Check point Water is drained Water inside the main unit is drained every after use. even after the faucet (P. EN27, EN31) is closed Water is not drained Is the drain hose bent or flattened? while alkaline ion • Running water continuously may cause malfunction. Also the water or acidic water water cannot be electrolyzed correctly.
  • Page 42: Optional Accessories

    Optional Accessories Obtain all optional accessories from your dealer. For details on how they are used, refer to the accompanying instructions. Consumables For use with large faucet Replacement cartridge Large-diameter Faucet Fitting Model No. : TK-AS500C-EX (inner diameter 32.5 mm) Model No.
  • Page 43 Specifications Rated voltage, frequency, input current 220-240 V ~ , 50 Hz, 0.7 A Rated power consumption Approx. 64 W (approx. 0.5 W during standby) Dimensions Approx. 168 (W) × 95 (D) × 333 (H) mm Main unit Approx. 2.4 k (approx. 2.8 k when full of water) Weight Temperature of water used by Alkaline Ionizer Under 35 °C (under 80 °C for bypass selector)
  • Page 44 愛心檢查 請對長年累月使用的鹼性離子整水器進行檢查 • 就算已將電源插頭插入 ,顯示 燈不點亮 為避免發生事故 ,請 是否有這樣的 • 出現異常顯示(U21 ~ U27) , 從插座拔下電源插 停止使用 現象? 即使處理異常顯示依舊出現 頭, 並務必委託經銷 • 出現異常顯示(H32 ~ H51 ) 商處理。 • 出現其他異常現象或故障 Panasonic Corporation https://www.panasonic.com ZGS0TKAS5000EXZ © Panasonic Corporation 2024 H0324-0 Printed in Japan...

Table of Contents