Notes for DME64N/DME24N Version 1.2
Thank you for purchasing the DME64N/DME24N. The following notes supplement the information in the Owner's Manual
about DME64N/DME24N.
Upgrading Cautions
• The following parameter will not be reflected in Version 1.2 when it is used to read data created in Version 1.0.0: SlotIn/SlotOut.
Remake these settings in DME Designer Version 1.2.
• Data created using Version 1.2 will not open properly on Version 1.1.
• Version 1.2 will not work with previous version in the area. When using Version 1.2, all DME firmware (program and components),
along with DME Designer, must be upgraded to Version 1.2 simultaneously. For instructions on performing the version upgrade,
see "DME Firmware Update" in Chapter 3 "Main Panel Window" of the "DME Designer Version 1.2 Owner's Manual."
• To use the DME CONTROL function on the PM5D, the PM5D must be version 1.12 or later, and connected DME64N/24N units
must be version 1.1 or later.
• For details about DME CONTROL function settings in the PM5D, see the "PM5D/PM5D-RH Owner's Manual."
Changes in Version 1.2
■ An Edit Indicator has been added.
If a parameter is changed after recalling a scene, a dot
will appear in the scene number indicator, and "EDIT"
will appear in the display.
■ The User-defined parameters display is changed.
"No Assign" settings in DME Designer are displayed as
dotted lines.
When [Parameter Value Edit] is selected the display will
be a solid line.
When [Direct Parameter Value], [Scene Change], [GPI
Out], or [Play Wav File] are selected, the display will be
inverted.
■ The Remote parameter has been added to Utility display "Misc" page.
• The REMOTE connector can be used as a MIDI connector.
• A new communications protocol allows AMX, Crestron, and other external devices to control the DME.
For details about the communication protocol refer to the "DME-N Remote Control Protocol Specifications" document.
The "DME-N Remote Control Protocol Specifications" document can be found at the Yamaha Pro Audio website:
http://www.yamahaproaudio.com/
HA Control (422)
COM (232C)
COM (422)
MIDI (232C)
MIDI (422)
Remote Ctrl (232C)
Remote Ctrl (422)
Added parameters are shown in bold.
External head amp control (RS-422 only)
Control using the DME communication protocol via RS-232C/RS-422.
Control using MIDI commands via RS-232C/RS-422.
Remote controller via RS-232C/RS-422.
EN

Advertisement

loading

Summary of Contents for Yamaha DME24N

  • Page 1 Notes for DME64N/DME24N Version 1.2 Thank you for purchasing the DME64N/DME24N. The following notes supplement the information in the Owner’s Manual about DME64N/DME24N. Upgrading Cautions • The following parameter will not be reflected in Version 1.2 when it is used to read data created in Version 1.0.0: SlotIn/SlotOut.
  • Page 2: Changes In Version

    When input-only or output-only cards like AD or DA cards are inserted in the slots, you cannot perform checks in this mode. In the DME24N, the internal AD and internal DA are directly connected on each channel. Notes for DME64N/DME24N Version 1.2...
  • Page 3 Detail Display: In the detail display, you select the parameter you want to display. Only information for that parameter appears on the DAW controller’s LCD screen. NOTE The number of characters that can be displayed is limited by the size of the DRAW’s LCD screen. Notes for DME64N/DME24N Version 1.2...
  • Page 4 KK, KL, KM, KN, KO, KP, KX, KY are the third and fourth digits of the serial number. A fee is charged for the hardware upgrade. For details, contact Yamaha customer support using the contact information located at the end of the “DME64N/24N Owner’s Manual.”...
  • Page 5 first time. The meter does not operate during the first startup. The [SIGNAL][PEAK] indicators also do not work in the DME24N. ■ There is an error on page 29 of the DME64N/24N Owner’s Manual, where it states that there is current between the OUT and GND [GPI] terminals.
  • Page 6: Message List

    Erase unused data such as configurations, presets, and audio data. Since this is likely to be a device failure, contact a Yamaha electric sound service outlet listed at the end of this manual (page 79). Set a valid IP address.
  • Page 7 NOTE For information about updated CD-ROM versions to be released in the future, contact the store where you purchased the device, or contact Yamaha customer service using the contact information at the end or your “DME64N/24N Owner’s Manual.” Content Retry the program update. If the update is still unsuccessful after several retries, a malfunction is likely.
  • Page 8 The following notes supplement the information in the DME64N/DME24N Owner’s Manual DME24N ANALOG INPUT CHARACTERISTICS Actual For Use Terminals Gain Load With Impedance Nominal CH INPUT -60dB 3kΩ 50 – 600Ω 1 – 8 Mics & 600Ω 10dB Lines • 0dBu = 0.775 Vrms •...

This manual is also suitable for:

Dme64n