Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet switches RUGGEDCOM i803 Communication Ports Technical Specifications Equipment Manual Certification 10/2023 C79000-G8976-1005-09...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer's exposure to cyber threats.
SIMATIC NET glossary The SIMATIC NET glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Registered trademarks The following and possibly other names not identified by the registered trademark sign ®...
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile app Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
Introduction The RUGGEDCOM i803 is a compact, fully managed Ethernet switch designed to operate reliably in harsh industrial environments. The flexibility of the RUGGEDCOM i803 allows the user to choose from managed or unmanaged, regular or extended temperature, fiber optical or copper interfaces, and fast or Gigabit Ethernet. With up to nine Ethernet ports, the RUGGEDCOM i803 is the perfect choice for a wide variety of demanding industrial environments such as those found in process control applications (oil and gas, petro-chemical, metals and mining, wind farms).
Introduction 1.2 Description • SSH/SSL (128-bit encryption) • Enable/disable ports, MAC based port security • Port based network access control (802.1x) • VLAN (802.1Q) to segregate and secure network traffic • RADIUS centralized password management • SNMPv3 authentication and 56-bit encryption Rated for Reliability in Harsh Environments •...
Introduction 1.3 Required Tools and Materials Failsafe Alarm Relay Power Supply Terminal Block Chassis Ground Terminal POWER LEDs ALARM LED Port Status LED Fiber Optic or Copper Gigabit Ethernet Ports Copper Ethernet Ports Access Plate RS-232 Console Port (RJ-45) Figure 1.1 RUGGEDCOM i803 Failsafe Alarm Relay Latches to default state when a power disruption or other alarm condition occurs.
WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of devices at public disposal sites. For environmentally friendly recycling and the disposal of devices, contact a certified disposal company for electronic scrap or your Siemens contact. For more information, refer to https://support.industry.siemens.com/cs/ww/en/ view/109479891.
Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment. Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Installing the Device 2.3 Mounting the Device Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM i803 can be ordered with a DIN rail adapter pre-installed on the back of the chassis. Use the adapter to latch the mount the device to a standard 35 mm (1.4 in) by 15 mm (0.6 in) IEC/EN 60715 or TS35 DIN rail.
Installing the Device 2.4 Connecting the Failsafe Alarm Relay (If Equipped) DIN Rail DIN Rail Adapter Figure 2.1 Mounting the Device to a DIN Rail Insert a flathead screw driver into the slot of the sliding release and move it down. Push the device against the bottom of the DIN rail, then let go of the sliding release to latch the device.
Installing the Device 2.5 Connecting Power Note Control of the failsafe relay output is configurable through RUGGEDCOM i803. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the "RUGGEDCOM ROS Configuration Manual" for the RUGGEDCOM i803.
Page 21
Installing the Device 2.5 Connecting Power Positive Terminal Negative Terminal GND Terminal Chassis Ground Terminal Figure 2.4 Terminal Block Wiring – Single DC Power Supply Input Connect the negative wire from the power source to the negative terminal (P1- or P2-) on the terminal block. [Optional] If connecting a second redundant power source, repeat step 1 (Page 11) and step 2 (Page 12), making sure to connect the power supply to the P2 ports.
Page 22
Installing the Device 2.5 Connecting Power Chassis Ground Terminal Figure 2.5 Terminal Block Wiring – Dual DC Power Supply Inputs Connect the chassis ground terminal to protective Earth. RUGGEDCOM i803 Equipment Manual, 10/2023, C79000-G8976-1005-09...
Page 23
Installing the Device 2.5 Connecting Power RUGGEDCOM i803 Equipment Manual, 10/2023, C79000-G8976-1005-09...
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM i803 console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM ROS Configuration Manual"...
Device Management 3.2 Configuring the Device The CTS and RTS pins are connected together internally. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM i803 console and Web interfaces via the device's IP address.
Page 26
Device Management 3.3 Inserting/Removing the MicroSD/MicroSDHC Card NOTICE Security hazard – risk of unauthorized access and/or exploitation. Make sure to remove the microSD/microSDHC card before decommissioning the device or sending the device to a third-party. To insert or remove a microSD/microSDHC card, do the following: Power down the device.
Communication Ports The RUGGEDCOM i803 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM i803. For more information on how to access the factory data file, refer to the "RUGGEDCOM ROS Configuration Manual"...
Communication Ports 4.2 Fiber Optic Ethernet Ports WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference If shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury.
Page 30
Communication Ports 4.2 Fiber Optic Ethernet Ports Tx Connector Rx Connector Figure 4.3 LC Port For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications" (Page 24). RUGGEDCOM i803 Equipment Manual, 10/2023, C79000-G8976-1005-09...
Technical Specifications This section provides important technical specifications related to the device and available modules. General specifications Insulation Class I Overvoltage category OVC II Power Supply Specifications Power Minimum Input Maximum Input Internal Maximum Power Supply Type Fuse Rating Consumption 24 VDC 9 VDC 32 VDC...
3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. Fixed Fast Ethernet Transceivers...
Technical Specifications 5.6 Operating Environment Operating Environment The RUGGEDCOM i803 is rated to operate under the following environmental conditions. Ambient Operating -20 to 60 °C (-4 to 140 °F) Temperature -40 to 85 °C (-40 to 185 °F) (Optional) Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F) Ambient Relative Humidity up to 95%...
Approvals This section details the standards to which the RUGGEDCOM i803 complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com/cs/ww/en/ps/16008/cert]. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 2058468: •...
Certification 6.1.2 European Union (EU) 6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 6.1.8 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Page 40
Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Earth ground ports IEC 61000-4-8 Magnetic Field Enclosure ports 30 A/m IEC 61000-4-29 Voltage Dips DC Power ports 30% reduction for 0.3 seconds 60% reduction for 1 second IEC 61000-4-12 Damped Oscillatory Signal ports 2.5 kV common, 1 kV...
Page 41
Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM i803 Equipment Manual, 10/2023, C79000-G8976-1005-09...