Page 1
LYNX Touch L5210/L7000 Series Security Systems Installation and Setup Guide 800-19974 12/14 Rev.B...
Page 2
LYNX Touch Installation and Setup Guide RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. Recommendations for Smoke and Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below.
LYNX Touch Installation and Setup Guide Table of Contents System Features ....................................5 Installing the Control ..................................7 Wall Mounting ....................................7 Desktop Mounting ..................................7 Wiring Overview .................................... 8 Wiring Connections ................................... 9 AC Power and Backup Battery ..............................10 General ........................................
Page 4
LYNX Touch Installation and Setup Guide Table of Contents (Continued) CDMA Information ..................................33 Communications ID Numbers ..............................33 Test Communications .................................. 33 Setup Communications ................................34 Registering the LYNX Touch ............................... 34 Register through AlarmNet 360 Website ............................ 34 Register by Phone ..................................
LYNX Touch Installation and Setup Guide System Features The LYNX Touch L5210 and L7000 series controls are self-contained, rechargeable wireless control/communicator that features easy installation and usage. A built-in speaker provides voice annunciation of system status along with voice descriptors of each zone. An internal module (if provided) allows the LYNX Touch to communicate with the Central Station via the Internet or Cellular Wireless.
Page 6
• Can be uploaded, downloaded or controlled via IBM-compatible computer using • Compass downloader software and specified HAYES or Honeywell CIA modem or via capable Cellular, IP or Wi-Fi communications module * L7000 requires Cellular, IP or Wi-Fi communications Flash downloading •...
LYNX Touch Installation and Setup Guide Installing the Control Wall Mounting For wall mounting follow the steps below and refer to the appropriate figure for the LYNX Touch L5210 OR L7000 control. Release the front case assembly from the back case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver.
LYNX Touch Installation and Setup Guide Installing the Control 5201-100-003-V0 7000-100-017-V0 L7000 Desk Mount L5210 Desk Mount Wiring Overview The following summarizes the electrical connections associated with the L5210/L5210CN and L7000/L7000CN. Refer to the Wiring Connections paragraph and the Summary of Connections diagram on the inside back cover when making connections.
LYNX Touch Installation and Setup Guide Wiring Connections INCOMING Make Earth Ground Connection - The designated earth ground PHONE LINE terminal EGND must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective. RING The following are examples of good earth grounds available at most installations:...
LYNX Touch Installation and Setup Guide AC Power and Backup Battery General The system is powered by a 9 Volt DC, 2.5 Amp Plug-in Power Supply, 300-04705V1, or 300-04065V1 (300- 04063V1 in Canada). Refer to the wiring table below for wire gauge and length. In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for connection and for low voltage conditions.
LYNX Touch Installation and Setup Guide Installing/Configuring Communication & Home Automation Modules The CDMA-L57 Communications Module is only available within the continental United States, Alaska and Hawaii. General This LYNX Touch controls support Central Station reporting using wireless/cellular (GSM or CDMA), Wi-Fi and hardwire (IP) communications modules.
LYNX Touch Installation and Setup Guide Installing/Configuring Communication & Home Automation Modules Installing the ILP5 Ethernet Communications Module Do not install the ILP5 if the L5100-WiFi communications module is being installed. Ensure that the connector board and cable are securely installed in the ILP5 before installing the communications module in the LYNX Touch.
LYNX Touch Installation and Setup Guide Installing Wireless Zones General Information Zones The L5210 and L7000 controls respectively support up to 79 and 103 total wireless zones using 5800 Series transmitters, and wireless buttons. Range The built-in RF receiver is capable of detecting signals from wireless transmitters within a nominal range of 200 feet.
LYNX Touch Installation and Setup Guide Installing Wireless Zones RF Sniffer Test Mode This mode is used after all transmitters have been entered to check that all transmitters have been properly programmed. Sniffer mode does not automatically expire. Sniffer mode must be manually exited to return to normal operation.
LYNX Touch Installation and Setup Guide Installing Wireless Zones 5800 Series Transmitter Loop Numbers (Refer to this information when programming transmitters) The following illustration shows the compatible transmitters, their associated input types and loop designations. LOOP 1 LOOP 1 (LOW (LOW SENSITIVITY SENSITIVITY...
LYNX Touch Installation and Setup Guide Mechanics of Programming Navigating Menus Touchscreen Display LYNX Touch’s Liquid Crystal Display (LCD) touch-screen displays variable icons and text on “screens”. The screen displays status icons and associated text, the current time and date, system status information and menu choices.
LYNX Touch Installation and Setup Guide Mechanics of Programming Navigation Keys Navigating through the screens is accomplished by lightly touching the icons or menu items on the touch- screen. Once activated, the control advances to the next screen. Selecting the “Home” (cancel) key or the “ ”...
LYNX Touch Installation and Setup Guide Mechanics of Programming Navigating Menus Security Screen System Status is displayed at the top of each screen and the time and date are displayed at the bottom of the Security Screen. The Security menu Screens differ between the LYNX Touch L5210 and the L7000 versions. Refer to the paragraphs below for additional information.
LYNX Touch Installation and Setup Guide Mechanics of Programming General Programming Information When power cycling the control, remove AC power first and wait approximately 1 minute before disconnecting battery. Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. The system can be programmed at any time, even at the installer's premises prior to the actual installation.
LYNX Touch Installation and Setup Guide Mechanics of Programming Loading Factory Defaults To load the factory defaults, enter the Installer Programming Mode and advance to second page of the System Programming and refer to following procedure. Refer to the Programming Default Values section of this manual to view the Default Values.
LYNX Touch Installation and Setup Guide Zone Response Type Definitions General Information During programming, you must assign a zone type to each zone, which defines the way in which the system responds to faults in that zone. Zone types are defined below. Type Function Characteristics...
Page 26
LYNX Touch Installation and Setup Guide Zone Response Type Definitions Type Function Characteristics Arm–Stay Special-purpose zone type used with 5800 Series • Exit delay regardless of the arming mode selected. wireless button units. • System is armed in the STAY mode when the zone is activated. Arm–Away Special-purpose zone type used with 5800 •...
LYNX Touch Installation and Setup Guide Programming the Control After entering the System Programming mode select from the options provided on the First and Second Installer Programming tools screens as shown in the accompanying figure. System Programming... System Programming... Sounder System Settings Installer Code System Type...
LYNX Touch Installation and Setup Guide Programming the Control Refer to the LYNX Touch L5210/L7000 Programming Guide (p/n 800-19976) or the LYNX Touch L5210CN/L7000 CN Programming Guide (p/n 800-20379) for additional information regarding programming options. System Type The following system options are programmed in this section: Option Function RF Jam...
LYNX Touch Installation and Setup Guide Programming the Control Program the Z-Wave Module The following system options are programmed in this section: Option Function Z-Wave Enables or disables the Z-Wave Module Temperature Display Toggles between Fahrenheit and Celsius (for Z-Wave compatible Thermostats) Program Zones The following system options are programmed in this section: Option...
LYNX Touch Installation and Setup Guide Programming the Control Program Reporting When Compass service is required and Cellular or IP are the only reporting channels: As part of Primary Central Station programming; the “Phone Type” must be set to any selection other than “None”, the “Communicator Type” must be set to Cellular or IP, as applicable, and must match the compass value;...
LYNX Touch Installation and Setup Guide Programming the Control Program Sounder The following system options are programmed in this section: Option Function Burglary Alarm Sound Reduces the full 85 dB burglary alarm sound for testing. Burglary Bell Timeout Select the time for timeout of the Burglary Alarm sounder. Fire Bell Timeout Select the time for timeout of the Fire Alarm sounder.
LYNX Touch Installation and Setup Guide Programming the Control Communications Diagnostics Communications Status – The system provides a status of the IP or Cellular communications paths and performs a self-test of the AES encryption algorithm as follows: Message Meaning Cellular: Normal;...
LYNX Touch Installation and Setup Guide Programming the Control CDMA Information – Displays CDMA information associated with the installed/enabled and registered CDMA-L57 Communications Module. Status Message Meaning CDMA Registered Cell Registration: Home CDMA Registered Home with CDMA 1x Service Roaming Registered Roaming Primary Site RSSI level signal strength (See RSSI...
Log in and follow the on-screen prompts. If required, click on “Dealer Signup” to gain access to the Honeywell web-based programming. Dealer Sign-Up Direct Link: https://services.alarmnet.com/AlarmnetDirectP_SignUp/Submission_Agree.aspx Complete the sign-up form then follow the instructions. Only one sign-up per dealer is required. Once an initial user is established, additional logins may be created by that user.
LYNX Touch Installation and Setup Guide Programming the Control Register through LYNX Touch Diagnostics Register the module using the LYNX Touch Diagnostics and the following procedure. SCREEN ACTION 1. Select “Comm. Diagnostics” The System displays the following options depending upon the communication device that is installed: Comm.
LYNX Touch Installation and Setup Guide Programming the Control Register Device with PIN This procedure is used to replace one LYNX Touch module with another. SCREEN ACTION 1. Select “Comm. Diagnostics” The System displays the following options depending upon the communication device that is installed: Comm.
LYNX Touch Installation and Setup Guide Programming the Control 2. Select “Setup Communication”. The System advances to the Registration screen and Setup the following options are displayed: Communication Register Register Device Device With PIN Update Factory Server Defaults 3. Select “Update Server” and select “Yes” when the confirmation screen appears. The device uploads its entire configuration file to the server.
LYNX Touch Installation and Setup Guide Programming the Control Enroll the L5100-WiFi Module The module can be enrolled using one of the following procedures: Scan Access Points • Manual Configure Access Points • • SCREEN ACTION 1. Select “Comm. Diagnostics” The System displays the following options depending upon the communication device that is installed: Comm.
LYNX Touch Installation and Setup Guide Programming the Control Manually Configure Access Points Note: For WEP Security type, the LYNX Touch supports the Key Index 1 in open system authentication mode. Select “Manually Configure AP”, the following screen is displayed. Ready To Arm Name SSID Toms_net...
LYNX Touch Installation and Setup Guide Programming the Control Factory Defaults This procedure resets the programming options to factory-default values. SCREEN ACTION 1. Select “Comm. Diagnostics” The System displays the following options depending upon the communication device that is installed: Comm.
Communications Modules. 2. Log in with your User Name and Password. If you are not signed up for this service, click on “Dealer Signup” from the login screen to gain access to the Honeywell web-based programming. Dealer Sign-Up Direct Link: https://services.alarmnet.com/AlarmNetDirectp_signup/Submission_Agree.aspx...
LYNX Touch Installation and Setup Guide Remote Programming/Control (Downloading) Compass Programming Advisory Notes A copy of the program downloaded may be printed using the IBM PC-compatible computer’s internal • report generator, when an optional printer is connected (consult your PC manual for proper printer and connections).
LYNX Touch Installation and Setup Guide System Operation Key/Touchscreen Operation The keys and touchscreen allows the user to arm and disarm the system, and perform other system functions, such as bypassing zones. Zone and system conditions (ALARM, trouble, bypass) are displayed on the display.
LYNX Touch Installation and Setup Guide System Operation Secondary User Codes In normal operation mode, the Master Code can be used to assign up to 30 (L5210/L5210CN) or 46 (L7000/L7000CN) secondary 4-digit security codes, including a Guest Code and a Duress Code. The Master Code can also be used to remove secondary codes from the system (individually).
LYNX Touch Installation and Setup Guide System Operation “Follow Me” System Announcement Feature (L5210/L5210CN Only) This feature allows the LYNX Touch to deliver a voice system message to the Follow Me Phone numbers programmed by the installer. The LYNX Touch will first transmit reports to the Central Station and after receiving its kiss-off, the system will dial the user phone numbers and begin transmitting the welcome message “System Message, Press Star to Play”.
LYNX Touch Installation and Setup Guide System Operation “Follow Me” Reminder Feature (L5210/L5210CN Only) The “Follow Me” feature allows the user to schedule a time driven message. When activated, the system will dial the Follow Me Phone 1 and/or the Follow Me Phone 2 telephone numbers, which are programmed by the installer (in the Reporter Programming section), and deliver a recorded message.
LYNX Touch Installation and Setup Guide System Operation System Displays The following icons will be displayed on the Home screen along with specific zone status information (if applicable) to indicate system status. DISPLAY DEFINITION DISPLAY DEFINITION DISPLAY DEFINITION AC Loss Door Open Fault * Garage Door...
LYNX Touch Installation and Setup Guide System Operation Audio alarm verification has not been evaluated by ETL. Audio Alarm Verification (Two-Way Voice Feature) This feature allows the Central Station operator to listen, talk to or conduct a two-way conversation with an individual(s) at the premises.
LYNX Touch Installation and Setup Guide System Operation Event Log The LYNX Touch Series event log is capable of recording and displaying up to 128 (L5210/L5210CN) or 256 (L7000/L7000CN) system events. The type of events that can be recorded is selectable and is programmed in the System Type programming field.
LYNX Touch Installation and Setup Guide System Operation Central Station Messages The following messages are sent by the communications modules ( 3GL/3GLC, CDMA-L57, ILP5 and L5100-WiFi) for the conditions listed below. Alarm Condition Alarm Code Restore Code Power On / Reset E339 C0803 Primary Communication Path Supervision E350 C0951...
LYNX Touch Installation and Setup Guide Testing the System TO THE INSTALLER Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system. The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts.
LYNX Touch Installation and Setup Guide Testing the System Dialer Test Note: This test is not available for the LYNX Touch L7000/L7000CN. The Dialer Test checks that the phone connection to the Central Station is working properly. Notify the Central Station in advance that tests will be in progress. 1.
LYNX Touch Installation and Setup Guide Zone Programming Default Values Zone Programming Notes Zone 1 is a hardwire zone; Zones 95, 96 and 99 are keypad panics. For the LYNX Touch L5210/L5210CN Zones 2 to 64 are RF zones (Zones 46 to 48 are reserved for Garage Door Zones); Zones 140-155 are RF Button Zones and 180-185 are Temperature Zones.
LYNX Touch Installation and Setup Guide Zone Programming Default Values Zone Assignment/Alarm Response Types for Values 3 and 4 Zone Loop Alarm Device Type Response Type Chime Supervision Zone Descriptor Number Number Report Night Not Used Disabled End of Line Door Entry Exit 1 Standard...
LYNX Touch Installation and Setup Guide Regulatory Agency Statements Federal Communications Commission (FCC) Part 15 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use.
Page 62
LYNX Touch Installation and Setup Guide RF Exposure Warning The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 7.8 in (20 cm) from all persons and must not be co-located or operated in conjunction with any other transmitter except in accordance with FCC multi-transmitter product procedures.
LYNX Touch Installation and Setup Guide WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
LYNX Touch Installation and Setup Guide Agency Notices 1. For Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60 seconds. For Burglar Alarm installations without line security, total exit delay time must not exceed 120 seconds.
LYNX Touch Installation and Setup Guide Specifications Physical: Dimensions: 8.5” W x 6” H x 1.875” D Electrical: Voltage Input: 9 Vdc from plug-in 2.5A power supply Rechargeable Backup Battery: Nickel-metal hydride battery pack rated at 7.2 Vdc Communication: Formats Supported: ADEMCO Contact ID®...
LYNX Touch Installation and Setup Guide Glossary Advanced Encryption Standard Advanced Protection Logic CDMA Code Division Multiple Access is a channel access method used by various radio communication technologies that allows many users to occupy the same time and frequency allocations in a given band/space.
Note the proper model number of this product, and the version level (if known) along with any documentation that came with the product. • Note your Honeywell customer number and/or company name. Having this information handy will make it easier for us to serve you quickly and effectively. Technical Support : .....................
LYNX Touch Installation and Setup Guide Notes: Connection of the fire alarm signal to a fire alarm headquarters or a Central Station shall be permitted with the approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police emergency number.