hit counter script
Download Print this page
Sealey SA51.V2 Quick Start Manual
Sealey SA51.V2 Quick Start Manual

Sealey SA51.V2 Quick Start Manual

Air needle scaler

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear ear
instruction
protection
manual
1. SAFETY
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
WARNING! Disconnect from air supply before changing accessories or servicing.
Maintain the needle scaler in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may
9
be dangerous and will invalidate the warranty.
WARNING! Check correct air pressure is maintained and not exceeded. We recommend 90psi.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure that all connections are
9
secure.
Only use needles which are specifically designed for use with a needle scaler.
9
Wear approved safety eye/face shield, ear defenders, and hand protection.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and non essential persons away from the working area.
9
DO NOT use the needle scaler for a task it is not designed to perform.
8
WARNING! DO NOT use needle scaler if damaged or thought to be faulty. (Contact Sealey stockist).
DO NOT use needle scaler unless you have been instructed in its use by a qualified person.
8
DO NOT carry the needle scaler by the air hose, or yank the hose from the air supply.
8
DO NOT operate needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT carry needle scaler with your hand on the power trigger in order to avoid unintentional starting.
8
DO NOT direct air from the air hose at yourself or others.
8
When not in use disconnect from air supply and store in a safe, dry, childproof location.
9
WARNING! The warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that
may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into
this product, but must be applied by the operator.
2. INTRODUCTION
Suitable for cleaning heavy paint and rust scale from metal surfaces. Palm control trigger mechanism. Replacement needle set available.
3. SPECIFICATION
Model no .................................................................. SA51.V2
Free speed .............................................................. 4800bpm
Inlet size ....................................................................1/4"BSP
Noise power/pressure ...........................................105/94dBA
Vibration/uncertainty ........................................ 9.84/1.34m/s²
Operating pressure ....................................................... 90psi
Stroke .......................................................................... 32mm
Consumable parts:
Replacement needle set (12pc) ............................... SA51/16
4. PREPARATION
4.1.
AIR SUPPLY
WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the needle scaler. Too high an air pressure and
unclean air will shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.
4.1.1.
Ensure needle scaler valve (or trigger) is in the "off" position before connecting to the air supply.
4.1.2.
You will require an air pressure of 90psi, and an air flow according to specification.
4.1.3.
Drain the air tank daily. Water in the air line will damage the needle scaler.
4.1.4.
Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig. 1.
4.1.5.
Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.
4.2.
COUPLINGS (See figs.1 & 2).
Vibration may cause failure if a quick change coupling is connected directly to the needle scaler. To overcome this, connect a leader hose
to the needle scaler. A quick change coupling may then be used to connect the leader hose to the air line recoil hose.
© Jack Sealey Limited
AIR NEEDLE SCALER
MODEL NO:
Wear eye
Wear a mask Wear protective
protection
Original Language Version
SA51.V2
gloves
SA51.V2 | Issue:1 03/02/20

Advertisement

loading

Summary of Contents for Sealey SA51.V2

  • Page 1 SA51.V2 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Sealey needles. Screw the needle tube (19) onto the barrel sleeve (12) and tighten. 6.2. Lubricate the needle scaler daily with a few drops of Sealey air tool oil dripped into the air inlet. 6.3. Clean the needle scaler after use.