Install Cisco NCS 1001
Figure 33: Cable Guide
1
2
The cable guide screw holding dome must face the inner side. Apply the torque value of 1.3 - 1.7 N-m (11.5
- 15.0 in-lbs) for 48-0654-01 screws. Based on the installation requirement, the cable guide can also be attached
by rotating it by 180 degrees.

Power Supply

NCS 1001 has two slots for 600W AC redundant Power Supply Units (PSU). It is sufficient to have a single
PSU inserted in the chassis to support all the features and provide power to all the pluggable modules. When
only one PSU is inserted in the chassis, the Power Module Redundancy Lost major alarm is raised.
Caution
Cable guide
Guide screws (part number - 48-0654-01)
In case of single PSU, the other PSU slot must be inserted with the PSU filler module to guarantee safety and
system cooling compliance.
Hardware Installation Guide for Cisco NCS 1001
Power Supply