hit counter script
Table of Contents

Advertisement

Install the FIPS Opacity Shield in a Two-Post Rack
Step 5
Route the cables through the openings in the cable management brackets as shown in the figure below.
Step 6
Attach the FIPS opacity shield to the cable management brackets using four of the 8-32 x 0.375-inch Phillips screws
provided in the FIPS kit as shown in the figure below.
Figure 28: Install the FIPS Cover
1
FIPS opacity shield
3
Cable management bracket
Step 7
Before you attach the TELs, clean the chassis and FIPS cover of any grease, dirt, or oil with alcohol-based cleaning
pads .
Step 8
Attach seven of the TELs. See the figure below for the correct placement. Allow the TELs to cure for a minimum of
12 hours.
Caution
Any deviation in the placement of the TELs means the chassis is not in FIPS mode.
Cisco Firepower 1100 Series Hardware Installation Guide
36
Installation, Maintenance, and Upgrade
2
8-32 x 0.375-inch Phillips screws (two per side)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents