Introduction Safety instructions Description SICHARGE Preparing for use SICHARGE UC 150 Installation Operating Instructions Connecting Commissioning Operation Handling alarms and errors Maintenance and service Disposal Service & Support Technical specifications Dimension drawings Declaration of Conformity 10/2022 List of abbreviations A5E50068475-AB...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Safety instructions..........................10 Basic safety instructions....................10 The five safety rules for electrical work................13 DC shutdown button......................14 Safety sign........................15 Cybersecurity at Siemens....................17 Identification of the device....................17 Description............................19 Product overview......................19 Display and operator controls.................... 20 Design of the charging station..................
Page 5
Settings..........................68 8.2.6.1 Settings..........................68 8.2.6.2 Last charging report......................69 8.2.6.3 Alert log........................... 8.2.6.4 Advanced mode........................ 71 Operation without HMI..................... 72 Handling alarms and errors........................ 74 Alarm messages in the alarm history................. 74 SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 6
Replacing an air filter......................83 10.4 Replacing the cabinet fan....................85 10.5 Replace lock cylinder......................87 Disposal.............................. Service & Support..........................90 12.1 Siemens Industry Support....................90 Technical specifications........................91 13.1 Technical specifications....................13.2 Power factor/efficiency..................... 13.3 Charging current/power curve................... 93 Dimension drawings...........................
The term "charging station" is used in this documentation for the "SICHARGE UC 150". Changes compared to previous version • Update of the chapter Maintenance plan (Page 79) • Update of the chapter Declaration of Conformity (Page 96) SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Siemens accepts no liability for the use of the open source software over and above the intended program sequence, or for any faults caused by modifications to the software.
The charging station is suitable for indoor and outdoor use. The permissible ambient conditions at the place of use must be observed for intended use. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 10
• Therefore, switch off the power supply before opening the door of the charging station. • If you open the door forcibly, the charging station automatically switches off the power supply to the AC‑DC converters. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 11
• Check the presence of all safety signs and warnings using the operating instructions • Attach missing safety signs and warnings • Do not remove safety signs and warnings • Replace unrecognizable safety signs and warnings SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
After finishing the work, remove the protective measures and switch the system on again: 1. Remove short-circuit 2. Remove grounding 3. Remove covers or barriers 4. Remove fuse to prevent restart 5. Switch the system back on SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
For safety reasons, the charging station cannot be operated in the DC shutdown state. The charging station only returns to its normal operating state after the button has been reset. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The following safety signs are attached to the packaging of the charging station: Safety sign Meaning Marking of the center of gravity Warning of tipping hazard Identification of locations that cannot be used for pickup using a forklift SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 15
The device does not contain any parts that can be maintained by the user. Only qualified personnel may open the device. The module has capacitors. Discharge the capacitors before you touch the connections. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Using versions that are obsolete or are no longer supported can increase the risk of cyber threats.
Page 17
You can find the following information on the nameplate of the charging station: Figure 2-2 Example: Charging station nameplate Position of the nameplate on the device The nameplate is located on the left exterior of the device in the lower left corner of the cabinet. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
DC output for dispenser - ✓ ✓ Application The charging station is designed for charging electric vehicles in semi-public commercial and industrial areas, for example: • Terminals • Vehicle depots • Company parking lots SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
To adapt the display to different lighting situations, the backlight of the display can be dimmed over a wide range of brightness. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 20
The door lock secures access to the interior of the charging station. You need a special door key to open the device door. The door key is included in the delivery. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
① Industrial Ethernet Switch ② Router for mobile communication ③ Line filter ④ Main contactors ⑤ Overvoltage protection ⑥ Miniature circuit breakers ⑦ Siemens controller ⑧ Figure 3-2 Interior front SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
① Electronic components DC output (accessible from the front) ② Inductors ③ Transformers Figure 3-3 Interior rear SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 23
An electromechanical actuator, therefore, automatically locks the plug-in connection in the electric vehicle after plugging in. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
For more information on connecting and operating charge points together with the charging station, refer to the following documentation: • SICHARGE UC Dispenser operating instructions • SICHARGE MastHood operating instructions • SICHARGE MastPanto operating instructions SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 25
In addition, the insulation monitoring device sends a message to the Siemens control system. For safety reasons, the charging station switches to the safe DC shutdown state. The charging station can no longer be operated in the DC shutdown state.
The shock indicator monitors any G-forces acting during the entire transport. If the charging station is subjected to unacceptably high G-forces during transport, the shock indicator is triggered. The indicator tube shows that the tolerance limit for G-forces has been exceeded by red coloring. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
4. Remove the cover of the transport packaging. 4.1.4 Report missing delivery components or transport damage If you discover that the delivery is incomplete or that there is transport damage, document the damage first. Then submit a damage report. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Restricting access Do not operate the charging station in public areas. Restrict access to the charging station in the semi-public area, e.g. with a fence. Figure 4-2 Restricting access SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 29
The maximum permissible temperature in the control cabinet is 45 °C. When the temperature rises above 45 °C, the rated output is reduced. Make sure that the ambient temperature does not exceed the maximum permissible temperature. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 30
Lay the cables carrying current separately and with a distance of at least 20 cm from the communication cables. NOTE Installer is responsible for calculation and design The installer is responsible for calculating and implementing the connection. Connection of the charging station must comply with standards and regulations. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 31
– The SICHARGE UC MastHood, MastPanto or Dispenser is designed for connection to the low-voltage network (230 V AC, 50 Hz, ±10%) via the charging station. Connect the device to the charging station using a properly dimensioned supply line. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 32
– Ethernet cables, low-voltage and DC cables may only cross each other at 90° angles. – Ground the shielding of the Ethernet cable at both cable ends. Bumper ① To protect the charging station against contact by vehicles, install a bumper SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Example of foundation Make a static calculation for the base area to ensure stability. This calculation must include the following factors, among others: • Ground survey • Wind load • Snow load • Earthquakes SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 34
The dimensions for the area of cable laying are specified in mm in the figure. ① Base area of charging station ② Area for the cable routing ③ Area for cable inlet ④ Reinforced concrete Figure 4-5 Example for footprint and foundation SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Safe operation of the device requires proper storage of the charging station. NOTICE Damage to property due to improper storage Improper storage may result in damage to the charging station, e.g. corrosion damage. Observe the conditions for proper storage. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 36
If you store the charging station for a longer period, also observe the following: • Use the original transport packaging. • Regularly check that the actual storage conditions do not allow condensation to form. • Check the charging station at regular intervals for damage. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The transport pallet protects the charging station from damage and facilitates transport. • Therefore, always transport the charging station on the transport pallet. Transporting the charging station with a forklift Figure 4-7 Forklift transport SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 38
15° to 60° between the chain and the load at the attachment point. We recommend, for example, a standard harness with 1 m sling chains of grade 8 or higher. Figure 4-8 Transport with crane SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 39
4. Hook the hoisting gear into the crane lugs. 5. Lift the charging station vertically. 6. Transport the charging station hanging upright to the site. 7. Remove the two rails and mount the cover plate. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
2. Loosen the four fastening screws of the cable gland plate. 3. Remove the cable gland plate from the cabinet. 4. Drill the holes for all connecting cables in the size of the cable glands used. 5. Mount the cable glands. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
4. Transport the charging station in a vertical position to the base. 5. Position the charging station above the base. Use suitable tools (e.g. wooden blocks) to secure the charging station against falling. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
• You have removed the cable bushing plates. • The cables for the connections protrude sufficiently from the foundation. Inserting the connecting cable into the cabinet Figure 5-2 Inserting the connecting cable into the cabinet SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The charging station is securely fixed to the base. To remove the transport aids, proceed as follows: 1. Remove the hoisting gear from the crane rails. 2. Remove the two rails. 3. Mount the cover plate on the charging station. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Dispenser, SICHARGE MastHood, or SICHARGE MastPanto. Install the cable gland plate 1. Push the cable gland plate onto the fastening screws in the cabinet floor. 2. Screw the nuts onto the fastening screws. 3. Tighten all nuts. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Mounting the protective cover To fit the protective cover, proceed as follows: 1. Position the protective cover. 2. Tighten the fastening screws of the protective cover. 3. Replace the main switch handle on the handle extension. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Note: Single-strand cables of class 1 and class 2 have the same conductor cross-section as cables of class 5 and class 6. However, they have a smaller diameter. This may result in clamping cables of equal diameters but different conductor cross-sections. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 47
They ensure a solid connection to the compact circuit breaker. Before the cable lug or end sleeve is attached to the cable, the cable is first stripped to size L. Use crimp-type cable lugs according to DIN 46234. Figure 6-4 Stripping insulation SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Requirements • You have removed the bottom protective cover. • You have inserted the power cable into the cabinet. • Cable cross-sections from 50 mm to a maximum of 300 mm can be connected. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 49
4. Select an M12-size cable lug for the corresponding conductor cross-section. 5. Strip off the end of the conductor so that the remaining insulation reaches up to the cable lug. 6. Fasten the cable lug correctly to the end of the conductor. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
DC cable to the DC+ and DC- connectors of the charging station. Requirements • You have removed the handle of the main switch. • You have removed the bottom protective cover. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 51
5. Plug the cable lug onto the bolt of the PE cabinet ground connection ③ 6. Tighten the fastening nut with the required torque: – Size of fastening nut: M12 – Required tightening torque: 20 Nm SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
When using the distributed charge points, connect the communication cable to the charging station. Requirements • You have removed the bottom protective cover. • You have inserted the communication cable into the cabinet and guided it upwards through the cable duct on the left side. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 53
Insert the RJ45 plug of the Ethernet cable into a free connection of the SCALANCE Ethernet switch. Connecting the fiber-optic cables Connect the fiber-optic cables to the optical ports of the SCALANCE Ethernet switch. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
6.5 External communication External communication You can equip the charging station with a router. The router can be installed for the wireless connection to the Siemens Configuration Backend and the OCPP backend. Router for mobile communication The slot for the SIM card is located between the LAN ports and the power supply. You can insert or remove the SIM card without removing the router.
③ Cable for the 230 V auxiliary current Figure 6-9 Cable routing for the auxiliary current Cable cross-sections up to a maximum of 4.0 mm can be connected to the terminals for the auxiliary power supply. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 56
4. Connect the N conductor of the cable to the "-QDP:4" terminal. 5. Make sure that the conductors are firmly connected to the screw terminal connections. You can find the terminal designations and the connection plan in the circuit diagram and here (Page 91). SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Take photos of the installation for the commissioning report. It is recommended to take pictures of the front and side view of each installed device (charging units, front ends, mast hoods). You can obtain the commissioning report and checklists from your Siemens partner. Installation check WARNING Switching off the circuit breaker Before proceeding with the checklist, make sure the circuit breaker is switched off.
Page 58
– Check the phase rotation. The phases must be connected to provide a clockwise rotating field. – Switch on the main switch of the charging unit charging station. – Ensure that the HMI is activated. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 59
7.1 Initial commissioning Software verification The service technician verifies and updates the versions of the following components as needed during initial commissioning: • Linux Siemens Charger Controller (SiCC) • Supply Equipment Communication Controller (SECC) • AC platform • Output platform •...
Page 60
• If the vehicle requests the charging process to stop at 100 %, the charging station stops. • If the vehicle request does not stop the charging process at 100 %, the charging station will continue with the process. The customer then has to stop the process. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The time is factory set to the UTC time zone. When the charging station is connected to the Internet, the time is synchronized. Information on how to set the time manually can be obtained from your Siemens partner. • Settings To go to the general settings (Page 68), press this display element.
The desired charging point is ready for use (the LED on the charging station lights up green). You can read the status of a charging station on the user interface or on the LEDs. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 63
The charging station is busy and is charging. – OUT OF SERVICE The charging station is out of service. 3. Select the type of charging cable. This example uses a CSS charging cable. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The charging plug is locked and the vehicle and charging station set up a connection. Communication setup may take up to 60 seconds. If communication has not been successfully established after 60 seconds, remove the charging cable and restart the process. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The following information is displayed: • Charging progress • Voltage, electric current and power at the output • Delivered energy Press the "Stop charging" button to manually terminate the charging process before it is completed. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
On the display you are asked whether you really want to end the charging process. Figure 8-5 Confirming termination of the charging process 3. Confirm the dialog with the "Stop charging" button. To cancel termination of the charging process and resume the charging process, press "No". SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
In the settings you can view information on the system and retrieve detailed information on the following areas: • Last report (Page 69) • Alert log (Page 70) • Advanced mode (Page 70) General system overview To open the screen settings, press on the icon. Figure 8-6 Settings SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
68). There may be several charging points connected to a charging station without their own user interface. In this case, select the desired charging point via the drop-down menu. Figure 8-7 Last charging report SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Confirm that you have read the error. Take further necessary steps if required. To close the area and return to the settings, press "Close". You can find more information on the error codes in the section "Handling alarms and errors (Page 74)". SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Current between the phases in Ampere Output Voltage at the output in Volt Current at the output in Ampere DC link voltage Voltage between rectifier and inverter Frequency Line frequency in Hz Table 8-2 Information about temperature SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The charging process is completed and the vehicle is still connected to the charging point. – Lit green The charging point is available and ready 2. To authenticate, hold the RFID card to the card reader. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 72
DC shutdown switch of the charging station. The charging plug locks and the vehicle is being charged. 4. Once the vehicle is charged or you finish charging via an external interface, remove the charging cable from your vehicle. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
In the event of a fault, the charging station triggers an alarm and automatically performs diagnostics. For each alarm, the charging station displays the following data in the "Alarm history" menu: • Alarm time • Date when the alarm was triggered • Alarm status • Alarm message SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 74
Voltage value too high for the momentary stage (IEC 61851, Annex C) highOutputCurrent Current value too high for this stage (IEC 61851, Annex C) ressTemperatureInhibit Electric vehicle fault evShiftPosition Electric vehicle fault chargerConnectorLockFault Electric vehicle fault evRessMalfunction Electric vehicle fault chargingCurrentDiff Electric vehicle fault SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 75
DC voltage value too high for the specific hardware dcOverCurrent DC current value too high for the specific hardware emergencyButtonPressed Feedback Emergency Off pressed received isolationFault Feedback Insulation monitoring failure received doorOpened Door is open SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 76
AC current value too high for the specific hardware softStartTimeout Timeout during switching ON/OFF of softStart converterTimeout Timeout during switching ON/OFF of the converter outputBreakerTimeout Timeout when closing/opening the output circuit breaker SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 77
Loss of communication with output platform (configurable timeout) communicationLostFans Loss of communication with fans (configurable timeout) emergencyButtonPressed Feedback Emergency Off pressed received isolationFault Feedback Insulation monitoring failure received doorOpened Door is open transformerThermostat Thermostat of transformer has tripped SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The charging station may be damaged. • During maintenance work, ensure that no foreign objects remain in and on the charging station. • Fasten loose components again after maintenance work. • Carefully remove any dirt. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Follow the test steps in document Preventive Maintenance Checklist (https://support.industry.siemens.com/cs/ww/en/view/109815371) You can find instructions on replacing the filter and fan in the following sections: • Filter change (Page 83) • Fan change (Page 84) SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Read the information on chemical resistance To ensure that the touch screen achieves the longest possible service life, observe the following information on the chemical resistance of SIMATIC HMI devices: Information on resistance (http://support.automation.siemens.com/WW/view/en/39718396) SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
• Soften paper stickers in advance for easy removal. Cleaning the charging cable • Only clean the charging cable when it is not connected. • Clean the charging cable with a dry cloth. • Never immerse the charging cable in liquids. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The following diagram shows the fan cover and the position of the air filters in the door. ① Filter for the upper fans ② Filter for the fans in the door Figure 10-1 Air filter with open door SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 83
7. Mount the lower fans and fix them to the guide rail with the two hexagon bolts. 8. Set the circuit breaker to the "ON" position. 9. Close and lock the door of the charging station. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
You will need the following tools to replace the cabinet fan: • Screwdriver • Bit: Hexagon socket, width across flats 6 • Screwdriver You will also need the following spare part: • Cabinet fan SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 85
1. Connect the connecting cables of the fan. 2. Insert the cabinet fan. 3. Tighten the fastening screws of the cabinet fan. 4. Set the circuit breaker to the "ON" position. 5. Close the door of the charging station. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The installed handle with lock has the part number "L2D0095760". Position of the lock cylinder The lock cylinder is located in the door lock of the cabinet door. Figure 10-5 Replacing the lock cylinder SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Page 87
4. Pull the lock cylinder ③ forwards out of the door lock. 5. Insert the new lock cylinder into the door lock. 6. Insert the adapter bar. 7. Close the door lock. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
For environmentally friendly recycling and disposal of the device, contact a certified electronic waste disposal company. Dispose of the device and specific material, for example, capacitors, in accordance with the applicable regulations in your country. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
• Type of the charging station • Serial number You can find this information on the nameplate of the charging station. The eMobility Team https://new.siemens.com/global/en/products/energy/medium- ) will also answer questions on voltage/solutions/emobility/sicharge-uc.html products and services. SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Siemens controller Local user interface 10" touch screen HMI (optional) User login RFID (optional) Network connection Ethernet interface or 3G and 4G or WLAN Electrical safety relay RCD Type B (optional) Communication protocol OCPP 1.6 (J‑SON) SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The following table shows the power factor and the efficiency depending on the output power. Table 13-2 Power factor/efficiency Output line Power factor Efficiency cos φ η 0.97 0.94 0.98 0.95 0.98 0.96 0.98 0.96 0.98 0.96 0.99 0.96 SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
The following figure shows the progression of the charging current depending on the charging voltage. Figure 13-1 Charging current Power curve The following figure shows the power curve depending on the charging voltage. Figure 13-2 Power curve SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Dimension drawings Dimension drawing of charging station Figure 14-1 Side and front view SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Survey method using an enveloping measurement surface over a reflecting plane Safekeeping location of the declaration of conformity SIEMENS AG keeps the EU Declaration of Conformity of the charging station available for the responsible authorities at the following location: Siemens AG...
Abbreviation Term Alternating current Controller Area Network Combined Charging System Direct Current DGUV German statutory accident insurance e.V. OCPP Open Charge Point Protocol Human Machine Interface IGBT Insulated-Gate Bipolar Transistor State of Charge SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...
Alarm messages in the alarm history, 74 Auxiliary power supply, 56 Auxiliary power supply Connecting cable Connecting, 56 Lead into the cabinet, 43 Connecting the power supply cable, 49 Cybersecurity at Siemens, 17 Bumper, 33 DC cable Connecting, 51 Cabinet DC shutdown, 14 Cleaning, 82...
Page 98
Packaging material Disposal, 89 Personal protective equipment, 11 Power curve, 93 Power factor, 92 Preparing the base area, 34 Product overview, 19 Protective cover Mounting, 46 Qualified personnel, 11 Replacing an air filter, 83 SICHARGE UC 150 Operating Instructions, 10/2022, A5E50068475-AB...