Supplement to the ES-200X Manual #LS10131-000FL-E Revision F dated 5/23/2022 for ES-200XP Applications Document LS10387-000FL-E Rev: A 2/23/2023 ECN:00029240...
Page 2
Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance! An automatic fire alarm system—typically made up of smoke IMPORTANT! Smoke detectors must be installed in the same room detectors, heat detectors, manual pull stations, audible warning as the control panel and in rooms used by the system for the devices, and a fire alarm control panel (FACP) with remote...
LiteSpeed™ and Lite-Connect™ are trademarks; and Fire-Lite® Alarms, Honeywell®, and SWIFT® are registered trademarks of Honeywell International Inc.Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. Chrome™ and Google™ are trademarks of Google Inc. Firefox® is a registered trademark of The Mozilla Foundation.
Your suggestion for how to correct/improve documentation Send email messages to: FireSystems.TechPubs@honeywell.com Please note this email address is for documentation feedback only. If you have any technical issues, please contact Technical Services. This symbol (shown left) on the product(s) and / or accompanying documents means that used electrical and electronic products should not be mixed with general household waste.
Page 5
Use this text to update the ES-200X Series Manual for ES-200XP applications. Fire-Lite Documents: HW-AV-LTE-M-FL CLSS Pathway Pro Document #LS10340-000HW-E 250V ES50- PCA REV ES200- PCA REV Supplement for ES-200XP Applications — P/N LS10387-000FL-E:A 2/23/2023...
Page 6
Peripheral Devices and Their Documents: ANN Audio Control for ECC-50/100 Doc. #LS10001-000FL-E ANN-RLY ANN-S/PG ANN-100 ANN-I/O Relay Card ANN-80 Printer Driver LCD Text Annunciator ANN-(R)LED LED Driver Doc. #53033 LCD Text Annunciator Doc. #151417 Doc. #LS10205-000FL-E LED Display Doc. #151416 Doc.
Page 7
1.8.4 FCC Compliance RI7ME310G1WW Contains FCC ID: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including, an interference that may cause undesired operation. •...
Page 8
NOTE: When using the CLSS Pathway Pro, CS Account Options and Supervision Settings are not configured at the panel. Use the CLSS Site Manager or the mobile app to configure Central Station settings. Visit www.fire.honeywell.com and refer to Section 2.8 for more information.
Page 9
9.3.2 How to Calculate System Current Load Use Table 9.3 on page 131 to calculate current load as follows: Enter the quantity of devices in all three columns. Enter the current draw where required. Refer to the Device Compatibility Document and SWIFT Manual for compatible devices and their current draws.
Page 10
Supplement for ES-200XP Applications — P/N LS10387-000FL-E:A 2/23/2023...
Page 11
ES-200XP Fire Alarm Control Panel Operating Instructions NORMAL - Only AC POWER is illuminated green. PANEL KEY - The key to open the panel can be found at the following All other indicators are off. LCD display will read SYSTEM NORMAL. location: ________________________________________________________ WHEN AUDIBLE DEVICES ARE SOUNDING -...