hit counter script
Siemens SIMATIC NET RUGGEDCOM M2100F Installation Manual

Siemens SIMATIC NET RUGGEDCOM M2100F Installation Manual

Hide thumbs Also See for SIMATIC NET RUGGEDCOM M2100F:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM M2100F
Edition
01/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM M2100F

  • Page 1 All manuals and user guides at all-guides.com Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM M2100F Edition 01/2020 https://www.siemens.com...
  • Page 2 All manuals and user guides at all-guides.com Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM M2100F Communication Ports Technical Specifications Installation Manual Certification 01/2020 C79000-G8976-1342-06...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Preface ............................v Related Documents ......................... v Accessing Documentation ....................... v Training ........................... v Customer Support ........................vi Contacting Siemens ........................ vi Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 All manuals and user guides at all-guides.com Table of Contents Supported Networking Standards ................ 25 Copper Ethernet Port Specifications ..............26 Fiber Optic Ethernet Port Specifications ............... 27 Operating Environment ..................28 Mechanical Specifications ..................28 Dimension Drawings ................... 28 Certification .........................
  • Page 6: Preface

    Siemens Customer Support. Training Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site cus- tomized courses tailored to the customer's needs, experience and application.
  • Page 7: Customer Support

    All manuals and user guides at all-guides.com Preface Customer Support Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Introduction

    All manuals and user guides at all-guides.com Introduction The RUGGEDCOM M2100F is a rugged, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically de- manding utility substation, railway and industrial environments. The RUGGEDCOM M2100F’s superior rugged hardware design coupled with the embedded Rugged Op- erating System (ROS) provides improved system reliability and advanced cyber secu- rity and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control applications.
  • Page 9: Description

    All manuals and user guides at all-guides.com Introduction 1.2 Description Universal Power Supply Options • Fully integrated, dual-redundant (optional) power supplies • Universal high-voltage range: 88-300 VDC or 85-264 VAC • Screw or pluggable terminal blocks for reliable, maintenance-free connections • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM M2100F features various ports, controls and indicator LEDs on the...
  • Page 10: Required Tools And Materials

    All manuals and user guides at all-guides.com Introduction 1.3 Required Tools and Materials Mode Color/State Description Green (Blinking) 1000 Mbps Orange (Solid) 10 Mbps No link detected Display Mode Indicator LEDs The display mode indicator LEDs indicate the current display mode for the port status indicator LEDs (i.e.
  • Page 11: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
  • Page 12: Supported Fiber Optic Cables

    NOTICE Worn, damaged or missing seals must be replaced immediately. Replacement seals are available for purchase from Siemens. For more information, contact a Siemens Sales representative. There are three ways to determine if a security seal has been tampered with: •...
  • Page 13 All manuals and user guides at all-guides.com Introduction 1.6 Tamper-Evident Security Seals For information about the placement of security seals, refer to the RUGGEDCOM RUGGEDCOM M2100F FIPS 140-2 Non-Proprietary Security Policy [https://support.in- dustry.siemens.com/cs/ww/en/view/109757984] RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 14: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 15: Unpacking The Device

    Visually inspect each item in the package for any physical damage. Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM M2100F is designed for maximum mounting and display flexibili- ty.
  • Page 16: 2.3.1 Mounting The Device To A Rack

    All manuals and user guides at all-guides.com Installing the Device 2.3.1 Mounting the Device to a Rack 2.3.1 Mounting the Device to a Rack The RUGGEDCOM M2100F can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 17: Mounting The Device To A Panel

    All manuals and user guides at all-guides.com Installing the Device 2.3.2 Mounting the Device to a Panel Make sure the rack mount adapters are installed on the correct side of the chas- sis. • To make the modules and ports accessible, install the rack mount adapters at the rear of the chassis •...
  • Page 18: Connecting The Failsafe Alarm Relay

    All manuals and user guides at all-guides.com Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel Adapter Figure 2.2 Panel Mounting...
  • Page 19: Connecting Power

    All manuals and user guides at all-guides.com Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.3 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM M2100F supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM M2100F can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies .
  • Page 20: 2.5.1 Connecting Ac Or Dc Power

    All manuals and user guides at all-guides.com Installing the Device 2.5.1 Connecting AC or DC Power • Equipment must be installed according to applicable local wiring codes and stan- dards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION Electrical hazard –...
  • Page 21 All manuals and user guides at all-guides.com Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) termi- nal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal...
  • Page 22: 2.5.2 Wiring Examples

    All manuals and user guides at all-guides.com Installing the Device 2.5.2 Wiring Examples Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power source to the chassis ground terminal on the device. Make sure the lug is tight- ened to 1.7 N·m (15 lbf·in).
  • Page 23 All manuals and user guides at all-guides.com Installing the Device 2.5.2 Wiring Examples Figure 2.6 Single AC Power Supply Figure 2.7 Single DC Power Supply RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 24 All manuals and user guides at all-guides.com Installing the Device 2.5.2 Wiring Examples Figure 2.8 Dual AC Power Supply Figure 2.9 Dual DC Power Supply RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 25 All manuals and user guides at all-guides.com Installing the Device 2.5.2 Wiring Examples Figure 2.10 Dual AC/DC Power Supply RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 26: Device Management

    All manuals and user guides at all-guides.com Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM M2100F console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM M2100F User Guide for the RUGGEDCOM M2100F.
  • Page 27: Configuring The Device

    All manuals and user guides at all-guides.com Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator   The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected.
  • Page 28: Communication Ports

    All manuals and user guides at all-guides.com Communication Ports The RUGGEDCOM M2100F can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM M2100F chassis: •...
  • Page 29: Copper Ethernet Ports

    All manuals and user guides at all-guides.com Communication Ports 4.1 Copper Ethernet Ports Port LED Figure 4.2 Port LEDs Copper Ethernet Ports The RUGGEDCOM M2100F supports several 10/100Base-TX and 10/100/1000Base- TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with Micro-D male connectors.
  • Page 30: Fiber Optic Ethernet Ports

    All manuals and user guides at all-guides.com Communication Ports 4.2 Fiber Optic Ethernet Ports Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ (Mechanical Transfer Reg- istered Jack), LC (Lucent Connector), SC (Standard or Subscriber Connector) or ST (Straight Tip) connectors.
  • Page 31 All manuals and user guides at all-guides.com Communication Ports 4.2 Fiber Optic Ethernet Ports RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 32: Technical Specifications

    All manuals and user guides at all-guides.com Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM M2100F can be equipped with the following power supplies: CAUTION Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range.
  • Page 33: Copper Ethernet Port Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 34: Fiber Optic Ethernet Port Specifications

    14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
  • Page 35: Operating Environment

    5.6 Operating Environment Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. Operating Environment The RUGGEDCOM M2100F is rated to operate under the following environmental conditions.
  • Page 36 All manuals and user guides at all-guides.com Technical Specifications 5.8 Dimension Drawings 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 37 All manuals and user guides at all-guides.com Technical Specifications 5.8 Dimension Drawings 32.77 21.08 11.68 479.29 478.79 4.57 Figure 5.2 Rack Mount Dimensions RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 38 All manuals and user guides at all-guides.com Technical Specifications 5.8 Dimension Drawings 467.4 275.6 482.6 Figure 5.3 Panel Mount Dimensions RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 39 All manuals and user guides at all-guides.com Technical Specifications 5.8 Dimension Drawings RUGGEDCOM M2100F Installation Manual, 01/2020, C79000-G8976-1342-06...
  • Page 40: Certification

    UL 60950-1 Information Technology Equipment – Safety Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 41: Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vi)".
  • Page 42: 6.1.6 Iso

    Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 43 All manuals and user guides at all-guides.com Certification 6.2 EMC and Environmental Type Tests EMC Type Tests per IEC 61850-3 Note • In the case of an all fiber port configuration, this product meets all Class 2 re- quirements. Otherwise, all Class 1 requirements are met for copper ports. •...
  • Page 44 5 kV   AC Power Ports   Siemens-specified severity levels EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM M2100F meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
  • Page 45 All manuals and user guides at all-guides.com Certification 6.2 EMC and Environmental Type Tests Description Test Levels Dielectric Signal Ports 2 kV Strength DC Power Ports 2 kV AC Power Ports 2 kV Damped Os- Enclosure Ports 100 A/m cillatory Mag- netic Field Environmental Type Tests Test...
  • Page 46 All manuals and user guides at all-guides.com Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents