hit counter script

Grounding The Device - Siemens SIMATIC NET RUGGEDCOM RS416P Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

Installing Device
2.5 Grounding the Device
Note
Control of the failsafe relay output is configurable through RUGGEDCOM RS416P.
One common application for this relay is to signal an alarm if a power failure occurs.
For more information, refer to the "RUGGEDCOM RS416P User Guide" for the
RUGGEDCOM RS416P.
The following shows the proper relay connections.
1
1
2
3
4
5
Figure 2.4
2.5

Grounding the Device

The RUGGEDCOM RS416P chassis ground terminal uses a #6-32 screw. It is
recommended to terminate the ground connection with a #6 ring lug and torque it
to 1.7 N·m (15 lbf·in).
1
2
14
Screw-Type Terminal Block
Pluggable Terminal Block
Normally Open Terminal
Common Terminal
Normally Closed Terminal
Failsafe Alarm Relay Wiring
1
Stainless Steel Stud
#6-32 Screw
3
5
4
2
3
3
5
4
RUGGEDCOM RS416P
Installation Manual, 11/2022, C79000-G8976-1019-11
2

Advertisement

Table of Contents
loading

Table of Contents