Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RS416P is available online at https:// support.industry.siemens.com.
Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
Introduction The RUGGEDCOM RS416P is an industrially hardened serial device server with an integrated, fully managed, 4-Port Power over Ethernet (PoE) switch, designed to operate reliably in electrically harsh and climatically demanding utility substation and industrial environments. Featuring a modular design that can support up to 16 serial ports, the RUGGEDCOM RS416P is able to interconnect multiple types of intelligent electronic devices (IEDs) that have different methods of communications.
Introduction 1.2 Description • Converts DNP3.0 to DNP over UDP/TCP Power Over Ethernet (PoE) • Two or four 10/100Base-TX 802.3af compliant ports • Data and power over a single Ethernet cable • Powered from the internal 48 VDC source • No mid-span patch panel required •...
Page 12
Introduction 1.2 Description Serial Ports Fiber Optic Ethernet and/or BNC (Optional) Ports Port Status Indicator LEDs Display Mode Indicator LEDs Mode Button Alarm Indicator LED Power Module Indicator LEDs RS-232 Serial Console Port (RJ45) Figure 1.1 RUGGEDCOM RS416P Communication Ports Ports for communicating with other devices or accessing the RUGGEDCOM RS416P operating system are described in "Communication Ports"...
Introduction 1.3 Required Tools and Materials Power Module Indicator LEDs The power module indicator LEDs indicate the status of the power modules. Color Description Green The power supply is supplying power Power supply failure No power supply is installed RS-232 Console Port The serial console port is for interfacing directly with the device and accessing initial management functions.
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
Introduction 1.6.1 Supported Time Synchronization Sources TTL OUT Port TTL IN Port Figure 1.2 PTP Module For more information about the BNC ports, refer to "BNC Ports" (Page 29). 1.6.1 Supported Time Synchronization Sources The following time synchronization sources are supported by the RUGGEDCOM RS416P, with or without the PTP card: Synchronization Source Without PTP Card...
Introduction 1.6.2 TTL Outputs Every Ethernet port on the RUGGEDCOM RS416P supports IEEE 1588. For more information, refer to "IEEE 1588 Support" (Page 1.6.2 TTL Outputs The PTP card provides a TTL (Transistor-Transistor Logic) output. The TTL OUT port supports the IRIG-B PWM and PPS signal formats. Enabling/ disabling the output port and selecting the signal format is controlled through the RUGGEDCOM RS416P operating system.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RS416P is designed for maximum mounting and display flexibility.
Installing Device 2.3.1 Mounting the Device to a Rack NOTICE Heat generated by the device is channeled outwards from the enclosure. As such, it is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some convectional airflow.
Installing Device 2.3.2 Mounting the Device on a DIN Rail If required, install adapters on the opposite side of the device to protect from vibrations. Insert the device into the rack. Note Since heat within the device is channelled to the enclosure, it is recommended that 1 rack-unit of space, or 44 mm (1.75 in), be kept empty above the device.
Installing Device 2.3.3 Mounting the Device to a Panel 2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS416P can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
Installing Device 2.5 Grounding the Device Note Control of the failsafe relay output is configurable through RUGGEDCOM RS416P. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the "RUGGEDCOM RS416P User Guide" for the RUGGEDCOM RS416P.
Installing Device 2.6 Connecting Power #6 Ring Lug Figure 2.5 Chassis Ground Connection Connecting Power The RUGGEDCOM RS416P supports a single high AC or low DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RS416P can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power module and PoE ports.
Page 25
Installing Device 2.6.1 Connecting AC or DC Power NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to a DC power supply terminal block. Damage to the power supply may occur. Note Terminals 5 and 7 (POWER 2) are reserved for the external PoE power supply. For information about connecting the external PoE power supply, refer to "Connecting External PoE Power"...
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to https:// support.industry.siemens.com/cs/ww/en/view/109478699.
Installing Device 2.6.3 Wiring Examples Screw-Type Terminal Block Pluggable Terminal Block Jumper Terminal 4 (Chassis Ground) Terminal 5 (+/L) Terminal 7 (-/N) Chassis Ground Terminal Figure 2.7 Terminal Block Wiring Connect the negative wire from the power source to terminal 7 (-/N) on the terminal block.
Page 28
Installing Device 2.6.3 Wiring Examples Figure 2.8 Single AC Power Supply Figure 2.9 Single DC Power Supply RUGGEDCOM RS416P Installation Manual, 11/2022, C79000-G8976-1019-11...
Page 29
Installing Device 2.6.3 Wiring Examples Figure 2.10 DC Power Supply and External PoE Power Supply Figure 2.11 AC Power Supply and External PoE Power Supply RUGGEDCOM RS416P Installation Manual, 11/2022, C79000-G8976-1019-11...
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS416P console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM RS416P User Guide"...
Device Management 3.2 Configuring the Device Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS416P console and Web interfaces via the device's IP address. For more information about available ports, refer to "Communication Ports"...
Communication Ports The RUGGEDCOM RS416P can be equipped with various types of communication ports to enhance its abilities and performance. Each communication port type has a specific place in the RUGGEDCOM RS416P chassis. Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Figure 4.1...
Communication Ports 4.2 PoE Ports WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference If shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury.
Communication Ports 4.3 Fiber Optic Ethernet Ports The total allowable power budget for all ports is 60 W. If the external power supply is less than 60 W, to prevent exceeding the power budget, port priorities can be set via the RUGGEDCOM RS416P operating system to disable low priority ports when demand is too high.
Communication Ports 4.4 Serial Ports (Straight Tip) connectors. Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Tx Connector Tx Connector Rx Connector Rx Connector Figure 4.5 LC Port Figure 4.4 MTRJ Port ...
Page 36
Communication Ports 4.4 Serial Ports State Description No link detected For specifications on serial ports, refer to "Serial Port Specifications" (Page 35). The following is the pin-out description for ST, DB9 and RJ45 serial ports: Fiber Serial Port Tx Connector Rx Connector Figure 4.8 ST Port Serial DB9 Port...
Page 37
Communication Ports 4.4 Serial Ports Serial DB9 Port with IRIG-B Support Mode RS232 DTE RS485 RS422 TX/RX+ IRIG-B+ Common (Isolated) Ground Common (Isolated) Ground TX/RX- Figure 4.10 Serial DB9 Port Pin Configuration Common (Isolated) Ground Shield Chassis Ground In RS232 DTE mode, ports transmit to DTE devices on pin 2 and receive from DTE on pin 3.
Communication Ports 4.5 BNC Ports Serial RJ45 Port with IRIG-B Support RS232 RS485 RS422 Mode Mode Mode +IRIG-B Common (Isolated) Ground Figure 4.12 Serial RJ45 Port Pin Common (Isolated) Ground Configuration TX/RX+ TX/RX- Shield Chassis Ground In RS232 mode, the RJ45 ports conform to EIA-561 DTE, which transmit on TXD and receive on RXD.
Communication Ports 4.6 Connecting Multiple RS485 Devices • Red – Error • Off – No signal detected Connecting Multiple RS485 Devices Each RS485 port can communicate with multiple RS485 devices by wiring devices together in sequence over a single twisted pair with transmit and receive signals on the same two wires (half duplex).
Technical Specifications This section provides important technical specifications related to the device and available modules. Power Supply Specifications Note For specifications on the PoE power supply, refer to "PoE Power Supply Specifications" (Page 33). Input Range Maximum Power Internal Fuse Isolation Power Supply Type...
Technical Specifications 5.4 Copper Ethernet Port Specifications Maximum Switching Voltage Rated Switching Current 80 VDC Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RS416P. Speed 10/100Base-TX Connector RJ45 Duplex FDX/HDX Cable Type >...
Approvals This section details the standards to which the RUGGEDCOM RS416P complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com]. 6.1.1 UKCA This device is certified for use in Great Britain and bears the United Kingdom Certified Assessed (UKCA) marking.
Certification 6.1.3 European Union (EU) 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.6 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 6.1.9 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: China RoHS 2 •...
Page 52
Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Enclosure Air ± 15 kV Radiated RFI Enclosure 20 V/m Note 61000-4-3 ports Burst (Fast Transient) Signal ports ± 4 kV @ 2.5 kHz Note 61000-4-4 DC Power ±...
Page 53
AC Power 5 kV ports Siemens specified severity level. IEEE 1613 EMC Immunity Type Tests Note RUGGEDCOM products meet Class 1 requirements for copper Ethernet configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
Page 54
Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-30 Humidity (Damp Test Db 95% (non- Heat, Cyclic) condensing), 55 °C (131 °F), 96 hours IEC 60068-2-6 Vibration 2 g @ 10-150 Hz Class 2 IEC 60068-2-27 Shock 30 g @ 11 ms...
Page 55
Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RS416P Installation Manual, 11/2022, C79000-G8976-1019-11...