ENGLISH Index Content Page # Components Safety Guidelines Description Specifications Installation Operation Maintenance Troubleshooting Performance Parts Notes Warranty Components 1 Float Switch 2 Handle 3 Motor 4 1-1/2 in. (38.1mm) Adapter 5 2 in. (50.8mm) Discharge 6 Base 7 Check Valve* *Included with DXWP62389 or sold separately under part no.
ENGLISH Safety Guidelines Carefully read, understand and follow all safety WARNING: Don’t expose the pump to freezing instructions in this manual. Retain this manual for temperatures. Discharge lines exposed to freezing temperatures future reference. should be positioned with a downward slope to prevent freezing. This is the safety alert symbol.
This sump pump is designed to remove ground water from residential sump basins. The motor is oil cooled and hermetically sealed. A float switch is provided for automatic operation and is equipped with a 10 ft., 3-prong grounding type power cord. Specifications DXWP62383 DXWP62583 DXWP62783...
ENGLISH Installation Figure 1: 1 Full-flow swing type check valve* WARNING: Always disconnect the power source before 2 GFCI outlet attempting to install, service or perform maintenance on the 3 Discharge Pipe pump. Failure to do so may result in fatal electrical shock. 4 Sump Basin NOTICE: This pump is designed and built to give you reliable 5 Position pump so the float switch operates freely...
Disassembly of the 4. DeWalt sump pumps are equipped with an (A) anti- motor housing or modification of the power cord voids airlock hole. A stream of water will emit from this hole the warranty.
ENGLISH Troubleshooting Problem Possible Causes How To Correct Pump is not plugged in; switch Plug pump in or turn on switch/breaker or breaker is turned off Check for blown fuses or tripped circuit breakers or Replace fuse, reset circuit breaker, reset GFCI outlet tripped GFCI outlets If the pump does not start or run...
Discharge height and/or pipe size and length will reduce the pump output performance. It is recommended to use the same size or larger pipe as the pump discharge for optimum performance. Performances below achieved using 2” PVC pipe. Model Number 30ft. / 9.14m DXWP62383 DXWP62389 25ft / 7.62m DXWP62381 DXWP62583 20 ft / 6.1m...
ENGLISH Replacement Parts For parts, contact customer support at 855-222-3841 or customer.service@pedrollo-usa.com DXWP62383 DXWP62583 DXWP62783 DXWP62183 Reference Description DXWP62389 DXWP62381 DXWP62581 DXWP62781 DWXP62181 Handle ADW100000 ADW100000 ADW100000 ADW100000 ADW100000 Power Cord 98101040 98101040 98101040 98101040 98101014 Shaft Seal T00900037/38 T00900037/38...
ENGLISH Limited Warranty: General Terms and Conditions - Cont: Manufacturer warrants the products specified in this Warranty will be VOID if any of the following conditions are warranty to be free from defects in material or workmanship found: for ten (10) years from date of purchase. During the Product is used for purposes other than those for which time period and subject to the terms and conditions, it was designed and manufactured.