® solution. SiPass integrated is the leading access control software on the market. This User’s Reference Manual provides a number of reference data tables that may assist you when assigning system functions, defining alarm classes, assigning operational modes to points, performing manual commands, creating event tasks and sending system messages.
Photo ID and Graphics functionality. The following table lists graphics file formats that are supported by SiPass Graphics integrated. They may be used in any aspect of the SiPass integrated Module, and as background images. Supported Format File Extension...
System Functions 3 System Functions This section lists of all the System Functions that can be assigned to operator Operator Group groups from the dialog. When assigning operator privileges, you must: 1. Assign the system functions to which that operator has access. 2.
Page 8
System Functions SystemFunction Description Assignable Privilege Level Anti-Passback Area Provides privileges for creating, modifying, <none>, c, e, v deleting and viewing Global Anti-Passback areas. Provides privileges to launch and see Advanced ASP Configuration <none>, c, e, v Security Programming module in SiPass Explorer (with ‘v’...
Page 9
FLN Configuration Provides privileges for the use of the <none>, c Network (FLN) Configuration tool built-in to the SiPass integrated application. This includes device settings and firmware download to local devices. Global Global Card Provides privileges for the use of the <none>, c...
Page 10
<none>, c, e, v Table in SiPass Explorer to create items in the current table. Provides privileges for sending manual Manual Control <none>, c commands from the SiPass integrated Workstation Client. Message Provides privileges for creating, modifying, <none>, c, e, v Forwarding...
Page 11
System Functions SystemFunction Description Assignable Privilege Level Service Provider Provides privileges for creating, modifying, <none>, c, e, v Configuration deleting and viewing service provider details. Smart Card Provides privileges for creating, modifying, <none>, c, e, v Encoding deleting and viewing the Smart Card encoding functionality details.
Alarm Class 4 Alarm Class This section lists all of the possible states and their descriptions for each Alarm Alarm Class Type in the dialog. When creating an alarm class, you can define alarm states. For example, if you were to create an alarm class for output points (in particular, doors with locks), you could create two states for that class.
Page 13
Alarm Class Type Status Description Intrusion Control Enabled Intrusion Control has been enabled at the reader. A duress alarm has been entered at an Duress access point. Soft Anti-passback mode A cardholder has failed to use their card when leaving an area with soft anti-passback and has tried to re-enter the same area.
Page 14
Alarm Class Type Status Description Soft Anti Pass Back Error A cardholder has failed to use their card when leaving an area with hard anti- passback and has tried to re-enter the same area. The cardholder will be denied access. Access Denied- Intrusion Access has been denied because an Area Armed...
Page 15
Alarm Class Type Status Description Workgroup Capacity The number of cardholders in the area from Exceeded a Workgroup has exceeded the maximum for that Workgroup. Workgroup Capacity Not The number of cardholders in the area from Full a Workgroup has not reached the maximum for that Workgroup.
Page 16
Alarm Class Type Status Description Image Normal The operator has privileges to allow or deny Verification entry based on visual identification of live Privilege and database cardholder images. The operator does not have privileges to Operator No IV privilege allow or deny entry based on visual identification of live and database cardholder images.
Page 17
Alarm Class Type Status Description Input tamper The input or wiring has been tampered with. Input open The input is an open circuit. Card limit reached The unit’s card limit has been exceeded Passback tamper A supervised passback input has detected a tamper.
Page 18
Power has been lost from the unit. Memory Overflow The backup flash memory is full. SALTO System Online SiPass integrated is connected to the SALTO System SALTO System Offline SiPass integrated is not connected to the SALTO System 18 | 66 A6V11144326...
Operational Modes 5 Operational Modes Operation modes are selectable only for points, not for devices. They affect how the points operate in relation to cardholders and the system. Type Mode Description Door Card Only A card must be presented at the access point to Reader gain valid access.
Page 20
Operational Modes Type Mode Description Card + PIN Arm/Disarm A card must be presented to gain access at the access point. A single card badge unlocks the door providing access without intrusion. A card badge with a PIN unlocks the door and simultaneously arms/disarms the intrusion area.
Page 21
Operational Modes Type Mode Description Card and Pin This mode provides the option to Access/Intrusion secure/unsecure the intrusion areas. In case the cardholder wants to arm/disarm/part-arm the area before a card is presented at the access point, it can be done by selecting a number from the reader keypad: Press ‘0’...
Page 22
Operational Modes Type Mode Description Input/Outpu Passback The input is in alarm state until the passback button has been pressed and the input delay is activated. Triggering passback unlocks the door latch. The input is in alarm state until the passback Passback No Message button has been pressed and the input delay is activated.
Page 23
Operational Modes Type Mode Description Fire Stair Defines the Input point as a fire stair door contact sensor. PIR mode defines the input point as a PIR detector. Normal Only Only normal states are reported to the system Alarm Only Only alarm states are reported to the system Report Disable Disables alarm reporting from the input point to...
● Permanents ● Reader Buzzer Off The Reader buzzer is turned off. Only applies to the Siemens reader range. Reader Buzzer On Reader buzzer is turned on. Only applies to the Siemens reader range. Reset Reader Resets the reader tamper input. Only applies to the Tamper Siemens reader range.
Page 25
Manual Override Type Command Description Set Mode “Card and Sets the point’s operation mode to “Card and PIN”. PIN” Set Mode “Card Only” Sets the point’s operation mode to “Card Only”. Set Mode “D.R. Card Sets the point’s operation mode to “Delayed and PIN”...
Page 26
Manual Override Type Command Description Set state Alarm Set the input to state Alarm. This is only applicable for Sintony input points of type “Serial Comms Input” Set the input to state Normal. This is only Set state Normal applicable for Sintony input points of type “Serial Comms Input”...
Page 27
Manual Override Type Command Description Part Arm Arms inputs which are marked as Part Arm. Arms inputs which are marked as Part arm B. (SPC Part Arm B intrusion only) Manually force-arms an intrusion area. This action Force Arm includes isolating input points that may be in the Alarm state, and then arming the area.
Sources 7 Host event tasks SiPass integrated allows you to define a host event task that performs a certain task (command) when a specific set of circumstances have been met (trigger). The following tables list the sources that can be used to trigger a host event task, along with a brief description of that source and the commands that can be implemented when the source has been triggered.
Page 29
A SALTO offline door requires a battery change. SALTO PPD A PPD has been connected to a SALTO offline Connection door to update the door. SALTO System SiPass integrated is not connected to the SALTO Offline System. SALTO System SiPass integrated is connected to the SALTO Online System.
Page 30
Host event tasks Sources Source State (trigger) Description Self Authorization Cardholder has self-authorized on a Dual Granted Custody access point. Soft Perimeter An anti-passback violation has occurred at a Violation door under soft anti-passback control. Time Schedule A host event task is triggered when a card is Violation presented at a reader outside the cards pro- grammed time schedule for that reader/door.
Page 31
Alarm An event is triggered when an External point (source point or area node) enters an alarm state and that information is sent to SiPass integrated by the exter-nal application. Normal An event is triggered when an External point...
Page 32
Host event tasks Sources Source State (trigger) Description Bank Floor Secure An event task is triggered when the floor is Secured. Bank Floor UnSecure An event task is triggered when the floor is not secured. Card No Access An event task is triggered when a cardholder badges their card and is not permitted access to that floor.
Page 33
Host event tasks Sources Source State (trigger) Description Normal An event task is triggered when the nominated area point goes into the normal operation state. An event task is triggered when an intrusion area Armed is armed. Arming Action An event task is triggered when an attempt to Complete arm a dependant intrusion area is complete.
Page 34
Host event tasks Sources Source State (trigger) Description Special Date Set time An event task is triggered at the nominated date time. Time format = HH:MM:SS An event task is triggered at the start of the Time Schedule Start nominated time schedule. Start and Stop An event task is triggered at both the start and end of the nominated time schedule.
Refer to Operational modes page 22 for more information. Reset Reader Tamper Resets the reader tamper. Only applies to the Siemens reader range. Block Door Blocks the door and prevents cards from being used to gain access at the door using the selected reader.
Page 36
Host event tasks Targets / Commands Target Command Description Unblock Door Returns a blocked door to its normal programmed mode of operation. Request Access Request a current access mode. Mode Set mode “No Dual Disables Dual Custody for the access point. Custody”...
Page 37
Displays a pre-configured alarm on the specified CCTV User’s Guide monitor. Refer to the more information. Database Database Backup: Performs a backup of the SiPass integrated data Data files. Database Backup: Performs a backup of the SiPass integrated Binaries binary files.
Page 38
Host event tasks Targets / Commands Target Command Description Floor Point As for Floor Points See above. Group Disables the input, if it is currently enabled, until Input Point Disable the next change in Time Schedule. Enable Enables the input, if it is currently disabled, until the next change in Time Schedule.
Page 39
Host event tasks Targets / Commands Target Command Description Slow Pulse Output The output will pulse slowly. For example, this could be used for alarms that utilize a pulsed output like strobes or sirens. Enter the time that you want the output to slow pulse into the Data field, using the format HH:MM:SS.
Page 40
Host event tasks Targets / Commands Target Command Description Shutdown Client Shuts down a SiPass integrated Client. Enter the Computer Name of the PC, on which the Client to be shutdown is running, into the Data field. For example, AUSSecServer103. Unit Full Initialization Performs a full initialization for the selected unit.
Controller Event Tasks Sources 8 Controller Event Tasks SiPass integrated allows you to define a controller event task that performs a certain task (command) when a specific set of circumstances have been met (trigger). Because controller event tasks are triggered by hardware events, you must select what type of component triggers or responds to the event.
Page 42
State (trigger) Description Reader Tamper OK An event task is triggered when a reader returns from a tamper state. Only valid for the Siemens reader range. Self Authorization Cardholder has self authorized on at Dual Granted Custody access point. An event task is triggered when a valid daily Valid Daily Code code has been entered at a keypad/reader.
Page 43
The Print Revision Number is updated each time the card is printed. This applies only to Siemens proprietary 52-bit card format. Door Interlocking In An event task is triggered if a card is badged a...
Page 44
State (trigger) Description Host Verify Message An event task has been triggered when a request for Image Verification has been sent from an access point to SiPass integrated. Host Verify Timeout An event task has been triggered when a card Message...
Page 45
Controller Event Tasks Sources Type State (trigger) Description Audit Trail Enabled An event task has been triggered when a controller event task is triggered when Audit Trail reporting from the ACC to the Server is enabled. An event task has been triggered when a Audit Trail Full controller event task is triggered when the Audit Trail log on the ACC is full.
Page 46
Controller Event Tasks Sources Type State (trigger) Description Online An event task has been triggered when communications between the device and the ACC are restored. An event task is triggered when the power Power Fail supply to the selected device fails. An event task is triggered when the power Power OK supply to the selected device has been re-...
Page 47
Controller Event Tasks Sources Type State (trigger) Description Door Opened An event task is triggered when a door monitor has registered that a door has been opened for longer than the Input Delay time. An event task is triggered when a device has Door Tamper registered that a supervised door monitor input has been tampered with.
Page 48
Controller Event Tasks Sources Type State (trigger) Description Exit Delay Timer An event task will be triggered when the exit Started delay timer has started. An event task will be triggered when the Normal intrusion area enters the normal state. Part Armed Intrusion Area has been Part Armed.
Controller Event Tasks Commands 8.2 Commands Controller event tasks allow you to perform a range of hardware-related tasks and trigger host event tasks in response to events. The following table lists the Types and Commands that can be selected when defining an Effect for a Controller Event Task.
Page 50
Only available for the Siemens reader range. Turns the buzzer for the specified reader Reader Buzzer on ON. Only available for the Siemens reader range. Turns the buzzer for the specified reader Reader Buzzer Off OFF. Only available for the Siemens reader range.
Page 51
Controller Event Tasks Commands Type Command Description Set mode “Authorization – Card Only” Set mode “Authorization – Card + PIN” Anti-Passback Reset Count Resets the current count for the anti- Area passback area to zero. Override Mode Override the selected area with a specific mode.
Page 52
Controller Event Tasks Commands Type Command Description Pulse Sends a pulse command to the selected Input. This is only applicable for Sintony input points of type “Serial Coms Input” Set state to Alarm Set the input to state Alarm. Set state to Normal Set the input to state Normal.
Page 53
Controller Event Tasks Commands Type Command Description Cancel Permanent Any current Permanent Command or Event Action Task, or Access/Internal Action operating on the target will be cancelled. The next Control State in the Control State Queue will take effect. Unlock, Override Door Unlocks the output and ignores any Door Interlocking Interlocking configuration.
ASP Trigger States 9 ASP Trigger States The following table lists the Point Types and Properties that can be selected for ASP Trigger State. Category Trigger Type Property Property Values Description Input Condition/Eve Input Logical Alarm Logical state of the Point State input.
Page 55
ASP Trigger States Category Trigger Type Property Property Values Description Event/Conditio Input Logical Short Circuit Tamper SPC Input State State Normal Alarm Open Circuit Tamper Tamper Fault Disabled Unsealed Isolated Event/Conditio Input Logical Normal Sintony input state State Alarm Unknown State Tamper Disabled in hardware Unsealed...
Page 56
ASP Trigger States Category Trigger Type Property Property Values Description Primary Card Only Mode The Primary Access Access Mode mode of the reader. Card & Pin Mode Host Verification Card Only mode Host Verification Card & Pin Mode View Only Card Only Mode View Only Card &...
Page 57
ASP Trigger States Category Trigger Type Property Property Values Description Event Only Invalid Daily True Code Valid Daily Shows Valid Daily True Code Code. Self True Indicates Self Authorize Authorized Access. Access Anti- Event/Conditio Area Empty False Indicates whether the Passback APB Area is empty.
Page 58
ASP Trigger States Category Trigger Type Property Property Values Description Event/Conditio Armed State Armed Indicates the Arming state of the Sintony Disarmed Intrusion Area. ExitDelay PartArmed Alarm State Alarm Indicates Alarm state of the External Normal Intrusion Area. EntryDelay Indicates the Arming Armed State Armed state of the SPC...
Page 59
ASP Trigger States Category Trigger Type Property Property Values Description Done False Gets the current value of the Timer Done. True Timing False Gets a value indicating whether the True timer is currently running. Event Only Time-out False Timeout Event for a Periodic Timer.
Page 60
ASP Trigger States Category Trigger Type Property Property Values Description Denied Void Card Card Events for Access Event Access Denied Pin Error Facility Error Group Error Passback Error Point Disabled Host Verification Timeout Card Revision Error Area Capacity Time Entry Error 3 PIN Void Card Not Yet Active Card Expired...
Page 61
ASP Trigger States Category Trigger Type Property Property Values Description Venue Event Only Booking After End After setting up a Offset Type venue, an ASP activity After Start can be configured to trigger an action Before End before or after every Before Start booking start or stop.
ASP Effect States 10 ASP Effect States The following table lists the Point Types and Properties that can be selected for ASP Effect State. Category Effect Type Property Property Values Description Input Regular Input Enabled False Enabled state of all the Point Effect input types except SPC.
Page 63
ASP Effect States Category Effect Type Property Property Values Description Access Regular Primary Card Only Mode The Primary Access Point Effect Access Mode Mode of the reader. Card & Pin Mode Host Verification Card Only mode Host Verification Card & Pin Mode View Only Card Only Mode View Only Card &...
Page 64
ASP Effect States Category Effect Type Property Property Values Description Return to Time True Returns to Time Schedule Schedule Control. Control Cancel Cancels Permanent True Permanent Override command. Override Access Unlock Override interlock and True Override unlock door. Interlock Allow Access True Override interlock and Override...
Page 65
ASP Effect States Category Effect Type Property Property Values Description Room 1 State Unknown Indicates the Arming state of the Sintony Room 2 State Armed Intrusion Area Room. Room 3 State Disarmed Room 4 State Room 5 State Room 6 State Room 7 State Room 8 State Bank...