Air-Conditioners
PCY-M•KAL-TH Series
INSTALLATION MANUAL
For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
FOR INSTALLER
English

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Mr.Slim PCY-M KAL-TH Series

  • Page 1 Air-Conditioners PCY-M•KAL-TH Series INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.
  • Page 2: Table Of Contents

    • If the air conditioner is installed in a small room or closed room, measures must • Use only accessories authorized by Mitsubishi Electric and ask a dealer or be taken to prevent the refrigerant concentration in the room from exceed- an authorized technician to install them.
  • Page 3: Installation Location

    1. Safety precautions 1.1. Before installation (Environment) Caution: • Do not use the unit in an unusual environment. If the air conditioner is installed • When the room humidity exceeds 80% or when the drainpipe is clogged, in areas exposed to steam, volatile oil (including machine oil), or sulfuric gas, water may drip from the indoor unit. Do not install the indoor unit where such areas exposed to high salt content such as the seaside, the performance can dripping can cause damage.
  • Page 4: Installing The Indoor Unit

    3. Installing the indoor unit 3.1. Check the indoor unit accessories (Fig. 3-1) The indoor unit should be supplied with the following accessories (contained in the inside of the intake grille). Accessory name Q’ty Washer 4 pcs Pipe cover 1 pc Large size (For gas tubing) Pipe cover 1 pc Small size (For liquid tubing) Band 4 pcs...
  • Page 5 3. Installing the indoor unit 3.2.2. Selection of suspension bolts and tubing positions (Fig. 3-3) Using the pattern paper provided for installation, select proper positions for suspen- sion bolts and tubing and prepare relative holes. A Pattern paper B Suspension bolt hole C Indoor unit width ø65 ø100 Secure the suspension bolts or use angle stock braces or square timbers for bolt installation.
  • Page 6: Installing The Refrigerant Piping

    4. Installing the refrigerant piping 4.1. Precautions For devices that use R32 refrigerant • Use C1220 copper phosphorus for copper and copper alloy seamless pipes, to connect the refrigerant pipes. Use refrigerant pipes with the thicknesses specified in the table below. Make sure the insides of the pipes are clean and do not contain any harmful contaminants such as sulfuric compounds, oxidants, debris, or dust.
  • Page 7: Drainage Piping Work

    5. Drainage piping work 5.1. Drainage piping work (Fig. 5-1) • For left side tubing, be sure to insert the rubber plug into the right drain port. (Fig. 5-1) • Use VP-20 (O.D. ø26 (1”) PVC TUBE) for drain piping and provide 1/100 or more downward slope.
  • Page 8 6. Electrical work 6.1.1. Indoor unit power supplied from outdoor unit The following connection patterns are available. 1 System The outdoor unit power supply patterns vary on models. 1:1 System A Outdoor unit power supply B Earth leakage breaker C Wiring circuit breaker or isolating switch D Outdoor unit E Indoor unit/outdoor unit connecting cords F Remote controller G Indoor unit...
  • Page 9 6. Electrical work 6.2. Remote controller 6.2.1. For wired remote controller (optional parts) Fig. 6 - 2 1) Installing procedures (1) Select an installing position for the remote controller. (Fig. 6-2) The temperature sensors are located on both remote controller and indoor unit. ► Procure the following parts locally: 2 piece switch box Thin copper conduit tube Lock nuts and bushings [Fig. 6-2]...
  • Page 10 6. Electrical work 5) Assigning a remote controller to each unit Each unit can be operated only by the assigned remote controller. Make sure each pair of an indoor unit PC board and a remote controller is assigned MODEL SELECT to the same pair No. 6) Wireless remote controller pair number setting operation (Fig. 6-7) 1 Press the SET button with something sharp at the end.
  • Page 11: Test Run

    6. Electrical work Function table Select unit number 00 Mode no. Setting no. Initial setting Setting Mode Settings Power failure automatic recovery Not available Available Indoor temperature detecting Indoor unit operating average Set by indoor unit’s remote controller Remote controller’s internal sensor LOSSNAY connectivity Not Supported Supported (indoor unit is not equipped with outdoor-air intake)
  • Page 12 7. Test run 7.2.2. Using wireless remote controller (Fig. 7-2) Turn on the power to the unit at least 12 hours before the test run. TEST RUN Press the button twice continuously. (Start this operation from the status of remote controller display turned off.) TEST RUN and current operation mode are displayed. TEST RUN MODE Press the button to activate mode, then check whether COOL...
  • Page 13 7. Test run • Refer to the following tables for details on the check codes. (Wireless remote controller) [Output pattern A] Beeper sounds Beep Beep Beep Beep Beep Beep Beep OPERATION · · · Repeated INDICATOR lamp blinking pattern Approx. 2.5 sec. 0.5 sec.
  • Page 14 7. Test run • If the unit cannot be operated properly after the test run has been performed, refer to the following table to remove the cause. Symptom Cause Wired remote controller LED 1, 2 (PCB in outdoor unit) After LED 1, 2 are lighted, LED 2 is turned •...
  • Page 15: System Control (For Puy Application Only)

    8. System control (For PUY application only) Refer to the outdoor unit installation manual. 9. Easy maintenance function (For PUY application only) By using the maintenance mode, you can display many types of maintenance data Display example (Comp discharge temperature 64 on the remote controller such as the heat exchanger temperature and compressor current consumption for the indoor and outdoor units.
  • Page 16 สารบั ญ 1. คำำ � แนะนำ � เพื่่ อ คำว�มปลอดภัั ย ....................16 6. ง�นเดิ น ส�ยไฟ ........................21 2. ตำำ � แหน่ ง ของก�รตำิ ด ตำั � ง ......................17 7. ท่ดลองเดิ น เคำร่ อ ง ........................25 3. ก�รตำิ ด ตำั � ง เคำร่ อ งภั�ยใน ......................18 8. ก�รคำวบคำุ...
  • Page 17 1. ค� า แนะน� า เพื ่ อ ความปลอดภั ย 1.1. ก่ อ นท� า การติ ด ตั ้ ง (สภาวะแวดล้ อ ม) ข้ อ ควรระวั ง : • อย ่ า ใช ้ เ คร ื ่ อ งในสภาวะแวดล ้ อ มท ี ่ ผ ิ ด ปกต ิ หากต ิ ด ต ั ้ ง เคร ื ่ อ งปร ั บ อากาศไว ้ ใ นพ ื ้ น ท ี ่ ท ี ่ ม ี • หากความช...
  • Page 18 3. การติ ด ตั ้ ง เครื ่ อ งภายใน 3.1. ตรวจสอบอุ ป กรณ์ เ สริ ม ของเครื ่ อ งภายใน (Fig. 3-1) เคำรื � อ งภั�ยในจะตำ้ อ งม�พื่ร้ อ มกั บ อุ ป กรณ์ เ สริ ม ดั ง ตำ่ อ ไปนี � (บรรจุ...
  • Page 19 3. การติ ด ตั ้ ง เครื ่ อ งภายใน 3.2.2. ก� า หนดต� า แหน่ ง ที ่ จ ะติ ด สลั ก เกลี ย วส� า หรั บ แขวนและท่ อ ระบายน� ้ า (Fig. 3-3) ใช้้ แ บบแปลนกระด�ษท่ี � จ ั ด ม�ให้ เลื อ กตำำ � แหน่ ง ท่ี � เ หม�ะสมสำ � หรั บ สลั ก เกลี ย วสำ � หรั บ แขวนและ ท่่...
  • Page 20 4. การติ ด ตั ้ ง ท่ อ สารท� า ความเย็ น 4.1. ข้ อ ควรระวั ง ส� า หรั บ อุ ป กรณ์ ท ี ่ ใ ช้ ส ารท� า ความเย็ น R32 • ใช้ ค อปเปอร์ ฟ อสฟอรั ส C1220 ส� า หรั บ ท่ อ ทองแดงและท่ อ ทองแดงผสมอั ล ลอยแบบไร้ ร อย ต...
  • Page 21 5. งานเดิ น ท่ อ ระบายน� ้ า 5.1. งานเดิ น ท่ อ ระบายน� ้ า (Fig. 5-1) • สำ � หรั บ ท่่ อ ด้ � นซ้ � ย ตำรวจดู ว ่ � เสี ย บจุ ก ย�งเข้ � ท่�งด้ � นขว�ของช้่ อ งท่่ อ ระบ�ยแล้ ว (Fig. 5-1) • ใช้้...
  • Page 22 6. งานเดิ น สายไฟ 6.1.1. แหล่ ง จ่ า ยไฟเครื ่ อ งภายในอาคารมาจากเครื ่ อ งติ ด ตั ้ ง ภายนอกอาคาร รู ป แบบก�รตำ่ อ วงจรไฟฟ้ � ท่ี � ส �ม�รถตำ่ อ ได้ ม ี ด ั ง นี � ในแตำ่ ล ะรุ ่ น รู ป แบบก�รตำ่ อ แหล่ ง จ่ � ยไฟเข้ � กั บ ตำั ว เคำรื � อ งภั�ยนอกอ�คำ�รจะแตำกตำ่ � งกั น ไป ระบบ 1:1 A แหล่...
  • Page 23 6. งานเดิ น สายไฟ 6.2. รี โ มทคอนโทรล 6.2.1. รี โ มทคอนโทรลแบบมี ส าย (ชิ ้ น ส่ ว นอุ ป กรณ์ เ สริ ม ) Fig. 6 - 2 1) ขั ้ น ตอนการติ ด ตั ้ ง (1) เลื อ กตำำ � แหน่ ง ท่ี � จ ะตำิ ด ตำั � ง รี โ มท่คำอนโท่รล (Fig. 6-2) เซ็...
  • Page 24 6. งานเดิ น สายไฟ 5) ก� า หนดรี โ มทคอนโทรลให้ ใ ช้ ไ ด้ เ ฉพาะแต่ ล ะเครื ่ อ ง แตำ่ ล ะเคำรื � อ งจะใช้้ ไ ด้ ก ั บ รี โ มท่คำอนโท่รลท่ี � ถ ู ก กำ � หนดไว้ เ ท่่ � นั � น โปรดตำรวจสอบแตำ่...
  • Page 25 6. งานเดิ น สายไฟ ตารางฟั ง ก์ ช ั น เลื อ กหม�ยเลขเป็ น 00 โหมด ก�รตำั � ง คำ่ � หม�ยเลขโหมด หม�ยเลขก�รตำั � ง คำ่ � คำ่ � ตำั � ง ตำ้ น ก�รตำั � ง คำ่ � กู ้ อ �ก�รไฟตำกอั ตำ โนมั ตำ ิ ไม่...
  • Page 26 7. ทดลองเดิ น เครื ่ อ ง 7.2.2. การใช้ ร ี โ มทคอนโทรลแบบไร้ ส าย (Fig. 7-2) เปิ ด เคำรื � อ งไว้ อ ย่ � งน้ อ ย 12 ช้ั � ว โมงก่ อ นท่ดสอบก�รท่ำ � ง�น TEST RUN กดปุ ่ ม สองคำรั � ง ตำิ ด ตำ่ อ กั น TEST RUN (ดำ...
  • Page 27 7. ทดลองเดิ น เครื ่ อ ง • ดู ร �ยละเอี ย ดเกี � ย วกั บ รหั ส ก�รตำรวจสอบได้ จ �กตำ�ร�งข้ � งล่ � งนี � (สำ � หรั บ รี โ มท่คำอนโท่รลไร้ ส �ย) [ผลลั พื่ ธ์ ร ู ป แบบ A] ปี...
  • Page 28 7. ทดลองเดิ น เครื ่ อ ง • ห�กเคำรื � อ งยั ง ไม่ ส �ม�รถท่ำ � ง�นเป็ น ปกตำิ ไ ด้ ห ลั ง จ�กก�รตำรวจสอบก�รท่ำ � ง�นข้ � งตำ้ น แล้ ว ให้ ด ู ตำ �ร�งตำ่ อ ไปนี � เ พื่ื � อ แก้ ไ ขปั ญ ห�ท่ี � ส �เหตำุ อ�ก�ร...
  • Page 29 8. การควบคุ ม ระบบ (ส� า หรั บ การใช้ ง าน PUY เท่ า นั ้ น ) ดู ร �ยละเอี ย ดจ�กคำู ่ ม ื อ ก�รตำิ ด ตำั � ง เคำรื � อ งตำิ ด ตำั � ง ภั�ยนอกอ�คำ�ร 9. ฟั ง ก์ ช ั ่ น บ� า รุ ง รั ก ษาอย่ า งง่ า ย (ส� า หรั บ การใช้ ง าน PUY เท่ า นั ้ น ) ด้...
  • Page 32 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Printed in Thailand VG79Y485H02...

Table of Contents